The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Open accessAbstract
Significance: Heart rate monitors, pacemakers, cardioverter-defibrillators, and neural stimulators constitute broad classes of electronic implants that rely on battery power for operation. Means for harvesting power directly from natural processes of the body represent attractive alternatives for these and future types of biomedical devices. Here we demonstrate a complete, flexible, and integrated system that is capable of harvesting and storing energy from the natural contractile and relaxation motions of the heart, lung, and diaphragm at levels that meet requirements for practical applications. Systematic experimental evaluations in large animal models and quantitatively accurate computational models reveal the fundamental modes of operation and establish routes for further improvements.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Specifically, recent studies have demonstrated the feasibility of piezoelectric,[327] near field communication (NFC),[328] and ultrasonic technologies[329] in power supply and data transmission.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [327]
In the citing paper
“However, these methods are anatomically specific and, in their existing forms, yield power densities too low (<0.1 μW/mm 2 ) for a microimplant.”
From Wireless power transfer to deep-tissue microimplants (2014) · cites this paper as [7]
In the citing paper
“Another piezoelectric energy harvester using the PZT ribbon is reported for scavenging the biomechanical energy from the motions of the heart, lung, and diaphragm [Fig.2(i)].70”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [70]
In the citing paper
“When attached on a bovine heart, the device is able to produce an output voltage of around 4 V.”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [70]
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922 · cited 1×
“Development of flexible devices based on arrays of piezoelectric ZnO nanowires (14, 15) represents an important step in this direction.”
Background1.6 V Nanogenerator for Mechanical Energy Harvesting Using PZT Nanofibers
Chen, X., Xu, S., Yao, N., & Shi, Y. (2010) · Nano Letters · doi:10.1021/nl100812k · Cited by 900
Human-powered wearable computing
Starner, T. (1996) · IBM Systems Journal · doi:10.1147/sj.353.0618 · Cited by 876 · cited 1×
“Investigations into energy-harvesting strategies to replace batteries demonstrate several unusual ways to extract power from chemical, mechanical, electrical, and thermal processes in the human body (1, 2).”
BackgroundPiezoelectric BaTiO3Thin Film Nanogenerator on Plastic Substrates
Park, K.-I., Xu, S., Liu, Y., Hwang, G.-T., Kang, S.-J. L., Wang, Z. L., & Lee, K. J. (2010) · Nano Letters · doi:10.1021/nl102959k · Cited by 827 · cited 1×
“Some improvement in performance is possible with thin-film geometries, as demonstrated in bending experiments on devices based on barium titanate (16) and lead zirconate titanate (PZT) (11, 12, 17).”
BackgroundFlexible High-Output Nanogenerator Based on Lateral ZnO Nanowire Array
Zhu, G., Yang, R., Wang, S., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl101973h · Cited by 805 · cited 2×
“[We note that alternative metrics for efficiency (13) lead to much higher values than those reported above.”
BackgroundQi, Y., Kim, J., Nguyen, T. D., Lisko, B., Purohit, P. K., & McAlpine, M. C. (2011) · Nano Letters · doi:10.1021/nl104412b · Cited by 516 · cited 1×
“Some improvement in performance is possible with thin-film geometries, as demonstrated in bending experiments on devices based on barium titanate (16) and lead zirconate titanate (PZT) (11, 12, 17).”
BackgroundImplanted Biofuel Cell Operating in a Living Snail
Halámková, L., Halámek, J., Bocharova, V., Szczupak, A., Alfonta, L., & Katz, E. (2012) · Journal of the American Chemical Society · doi:10.1021/ja211714w · Cited by 486 · cited 1×
“Examples include use of glucose oxidation (3), electric potentials of the inner ear (4), mechanical movements of limbs, and natural vibrations of internal organs (5–7).”
BackgroundChoi, M., Choi, D., Jin, M., Kim, I., Kim, S., Choi, J., Lee, S. Y., Kim, J. M., & Kim, S. (2009) · Advanced Materials · doi:10.1002/adma.200803605 · Cited by 439
Transient, Biocompatible Electronics and Energy Harvesters Based on ZnO
Dagdeviren, C., Hwang, S., Su, Y., Kim, S., Cheng, H., Gur, O., Haney, R., Omenetto, F. G., Huang, Y., & Rogers, J. A. (2013) · Small · doi:10.1002/smll.201300146 · Cited by 412 · cited 2×
“2F for ΔLmax = 10 mm) and work done (19) in each cycle RΔLmax 0 FdΔL, where F = 4π(2)wPIEIPI=L(2) is the bucking force (SI Appendix, Fig.”
BackgroundSelf-citationA very low-power CMOS mixed-signal IC for implantable pacemaker applications
Wong, L. S. Y., Hossain, S., Ta, A., Edvinsson, J., Rivas, D. H., & Naas, H. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.837027 · Cited by 395
Research works printed but not linked: 1
- FA Baciewicz, DG Penney, WA Marinelli, R Marinelli, Torsional ventricular motion and rotary blood flow. Cardiac Chronicle 5, 1–8 (1991).
Cited by
Science and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems
Ferrari, A. C., Bonaccorso, F., Fal'ko, V., Novoselov, K. S., Roche, S., Bøggild, P., Borini, S., Koppens, F. H. L., Palermo, V., Pugno, N., et al. (2015) · Nanoscale · doi:10.1039/c4nr01600a · Cited by 3,027
Self-citationFlexible Nanogenerators for Energy Harvesting and Self‐Powered Electronics
Fan, F. R., Tang, W., & Wang, Z. L. (2016) · Advanced Materials · doi:10.1002/adma.201504299 · Cited by 1,918
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
“mechanisms.(54,120,126-131,133-134,136-137) The values of power listed in the table refer to the power”
BackgroundTechnology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationHigh-Performance Piezoelectric Energy Harvesters and Their Applications
Yang, Z., Zhou, S., Zu, J., & Inman, D. (2018) · Joule · doi:10.1016/j.joule.2018.03.011 · Cited by 1,264
Metadata
- Authors
- Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., Lu, B., Poston, R., Khalpey, Z., Ghaffari, R., Huang, Y., Slepian, M. J., & Rogers, J. A.
- Affiliations
- Department of Materials Science and Engineering, Beckman Institute for Advanced Science and Technology, and Frederick Seitz Materials Research Laboratory, and
- Northwestern University (US)
- Department of Medicine and Sarver Heart Center and
- Departments of eSurgery and
- Tsinghua University (CN)
- Center for Mechanics and Materials and
- MC10 (United States) (US)
- University of Arizona (US)
- University of Illinois Urbana-Champaign (US)
- ORCID
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2014-01-21
- Volume
- 111
- Issue
- 5
- Pages
- 1927-1932
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC3918766
- OpenAlex
- W2151263439
- Semantic Scholar
- cc964bc8a81953562c1114871f1173d22240d91c
- Cited by
- 975
- References
- 33
- Citations by year
- 2026: 73 · 2025: 80 · 2024: 66 · 2023: 63 · 2022: 89 · 2021: 83 · 2020: 96 · 2019: 90 · 2018: 100 · 2017: 83 · 2016: 68 · 2015: 52 · 2014: 32
- FWCI
- 91.20
- Type
- journal article
- Language
- en
- Update notices
- correction (2021-07-19)
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. Department of Energy (DEFG0207ER46471)
- National Institute of Biomedical Imaging and Bioengineering (U01EB012487)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Energy › Nuclear Energy and Engineering › Advanced Energy Technologies and Civil Engineering Innovations
- Keywords
- piezoelectric energy harvesting, mechanical-to-electrical energy conversion, cardiac motion, lung motion, diaphragm motion, rectifier, cardiac pacemaker, implantable power sources, animal models
- MeSH terms
- Animals, Cattle, Diaphragm, Heart, Humans, Lung, Motion, Electric Power Supplies, Sheep, Rats, Electrophysiological Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm. https://app.cochat.ai/papers/10.1073/pnas.1317233111
- The paper
- Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., Lu, B., Poston, R., Khalpey, Z., Ghaffari, R., Huang, Y., Slepian, M. J., & Rogers, J. A. (2014). Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1317233111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.