The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Thermoelectric coolers as thermal management systems for medical applications: Design, optimization, and advancement
Abstract
Abstract Compared with traditional cooling techniques, thermoelectric coolers have drawn massive attention for small-scale cooling applications, particularly in medical practices. Thermoelectric coolers offer the benefits of having more environmentally friendly systems, a silent and robust structure, and reliable temperature control. Considering the recent rapid developments in this field, this article comprehensively reviews thermoelectric refrigerators for thermal management systems in medical practices, such as cooling carriers and wearable medical devices. Thermal optimization of thermoelectric coolers is assessed according to the available mechanisms, namely 1) using efficient thermoelectric materials, 2) designing efficient heat sink and absorption - especially applying phase change materials, and heat pipes, and 3) production methods for flexible thermoelectric devices, such as printing techniques. In the end, we point out that novel thermoelectric cooler technologies have gradually replaced traditional refrigerators due to their advantages of small size, flexibility, and pollution-free characteristics for medical applications, alongside wearable technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Lee, J., Sul, H., Lee, W., Pyun, K. R., Ha, I., Kim, D., Park, H., Eom, H., Yoon, Y., Jung, J., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909171 · Cited by 176
Advanced Thermoelectric Materials for Flexible Cooling Application
Ding, J., Zhao, W., Jin, W., Di, C., & Zhu, D. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202010695 · Cited by 123
Cited by
Thermoelectric coolers for on-chip thermal management: Materials, design, and optimization
Chen, W.-Y., Shi, X.-L., Zou, J., & Chen, Z.-G. (2022) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2022.100700 · Cited by 312
Self-citationToward Efficient Thermoelectric Materials and Devices: Advances, Challenges, and Opportunities
Shi, X.-L., Li, N.-H., Li, M., & Chen, Z.-G. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.5c00060 · Cited by 260
Self-citation
Metadata
- Authors
- Zaferani, S. H., Sams, M. W., Ghomashchi, R., & Chen, Z.-G.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2021-12
- Volume
- 90
- Pages
- 106572
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W3203760562
- Cited by
- 162
- References
- 3
- FWCI
- 7.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermoelectric coolers as thermal management systems for medical applications: Design, optimization, and advancement. https://app.cochat.ai/papers/10.1016/j.nanoen.2021.106572
- The paper
- Zaferani, S. H., Sams, M. W., Ghomashchi, R., & Chen, Z.-G. (2021). Thermoelectric coolers as thermal management systems for medical applications: Design, optimization, and advancement. Nano Energy. https://doi.org/10.1016/j.nanoen.2021.106572
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.