Solid-state and biological nanopore for real-time sensing of single chemical and sequencing of DNA
Open accessThe DOI matches its Crossref record; 97 of the 97 references it cites were found in a registry or an index.
Abstract
Sensitivity and specificity are two most important factors to take into account for molecule sensing, chemical detection and disease diagnosis. A perfect sensitivity is to reach the level where a single molecule can be detected. An ideal specificity is to reach the level where the substance can be detected in the presence of many contaminants. The rapidly progressing nanopore technology is approaching this threshold. A wide assortment of biomotors and cellular pores in living organisms perform diverse biological functions. The elegant design of these transportation machineries has inspired the development of single molecule detection based on modulations of the individual current blockage events. The dynamic growth of nanotechnology and nanobiotechnology has stimulated rapid advances in the study of nanopore based instrumentation over the last decade, and inspired great interest in sensing of single molecules including ions, nucleotides, enantiomers, drugs, and polymers such as PEG, RNA, DNA, and polypeptides. This sensing technology has been extended to medical diagnostics and third generation high throughput DNA sequencing. This review covers current nanopore detection platforms including both biological pores and solid state counterparts. Several biological nanopores have been studied over the years, but this review will focus on the three best characterized systems including α-hemolysin and MspA, both containing a smaller channel for the detection of single-strand DNA, as well as bacteriophage phi29 DNA packaging motor connector that contains a larger channel for the passing of double stranded DNA. The advantage and disadvantage of each system are compared; their current and potential applications in nanomedicine, biotechnology, and nanotechnology are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Characterization of individual polynucleotide molecules using a membrane channel
Kasianowicz, J. J., Brandin, E., Branton, D., & Deamer, D. W. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.24.13770 · Cited by 3,362
The potential and challenges of nanopore sequencing
Branton, D., Deamer, D. W., Marziali, A., Bayley, H., Benner, S. A., Butler, T., Di Ventra, M., Garaj, S., Hibbs, A., Huang, X., et al. (2008) · Nature Biotechnology · doi:10.1038/nbt.1495 · Cited by 2,534
Structure of Staphylococcal α-Hemolysin, a Heptameric Transmembrane Pore
Song, L., Hobaugh, M. R., Shustak, C., Cheley, S., Bayley, H., & Gouaux, J. E. (1996) · Science · doi:10.1126/science.274.5294.1859 · Cited by 2,377
Dekker, C. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.27 · Cited by 1,933
Continuous base identification for single-molecule nanopore DNA sequencing
Clarke, J., Wu, H.-C., Jayasinghe, L., Patel, A., Reid, S., & Bayley, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.12 · Cited by 1,810
Self-citationIon-beam sculpting at nanometre length scales
Li, J., Stein, D., McMullan, C., Branton, D., Aziz, M. J., & Golovchenko, J. A. (2001) · Nature · doi:10.1038/35084037 · Cited by 1,677
Self-citationGraphene as a subnanometre trans-electrode membrane
Garaj, S., Hubbard, W., Reina, A., Kong, J., Branton, D., & Golovchenko, J. A. (2010) · Nature · doi:10.1038/nature09379 · Cited by 1,439
Fabrication of solid-state nanopores with single-nanometre precision
Storm, A. J., Chen, J. H., Ling, X. S., Zandbergen, H. W., & Dekker, C. (2003) · Nature Materials · doi:10.1038/nmat941 · Cited by 1,364
Nanopore sensors for nucleic acid analysis
Venkatesan, B. M., & Bashir, R. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.129 · Cited by 1,302
Stochastic sensors inspired by biology
Bayley, H., & Cremer, P. S. (2001) · Nature · doi:10.1038/35093038 · Cited by 1,118
Cited by
The sequence of sequencers: The history of sequencing DNA
Heather, J. M., & Chain, B. (2016) · Genomics · doi:10.1016/j.ygeno.2015.11.003 · Cited by 1,397
“Despite the admittedly poor quality pro fi les currently observed, it is hoped that such sequencers represent a genuinely disruptive technology in the DNA sequencing fi eld, producing incredibly long read (non-ampli fi ed) sequence data far cheaper and faster than was previously possible [92,90,85].”
Tetraphenylethylene-Based AIE-Active Probes for Sensing Applications
La, D. D., Bhosale, S. V., Jones, L. A., & Bhosale, S. V. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b12320 · Cited by 585
Next generation sequencing and its applications in forensic genetics
Børsting, C., & Morling, N. (2015) · Forensic Science International: Genetics · doi:10.1016/j.fsigen.2015.02.002 · Cited by 460
“The MinION platform uses a completely different technology based on the transport of DNA molecules through a nanopore embedded in a lipid bilayer or a synthetic polymer [30,41,42].”
BackgroundMethodNanopore-Based Fourth-Generation DNA Sequencing Technology
Feng, Y., Zhang, Y., Ying, C., Wang, D., & Du, C. (2015) · Genomics, Proteomics & Bioinformatics · doi:10.1016/j.gpb.2015.01.009 · Cited by 431
Biomimetic membranes: A review
Shen, Y.-X., Saboe, P. O., Sines, I. T., Erbakan, M., & Kumar, M. (2014) · Journal of Membrane Science · doi:10.1016/j.memsci.2013.12.019 · Cited by 380
Synthesis, Assembly, and Applications of Hybrid Nanostructures for Biosensing
Zhang, S., Geryak, R., Geldmeier, J., Kim, S., & Tsukruk, V. V. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00088 · Cited by 340
Zhang, H., Tian, Y., & Jiang, L. (2016) · Nano Today · doi:10.1016/j.nantod.2015.11.001 · Cited by 324
Direct observation of DNA knots using a solid-state nanopore
Plesa, C., Verschueren, D., Pud, S., van der Torre, J., Ruitenberg, J. W., Witteveen, M. J., Jonsson, M. P., Grosberg, A. Y., Rabin, Y., & Dekker, C. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.153 · Cited by 273
Confined Nanopipette Sensing: From Single Molecules, Single Nanoparticles, to Single Cells
Yu, R., Ying, Y., Gao, R., & Long, Y. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201803229 · Cited by 255
Recent Progress in Solid‐State Nanopores
Lee, K., Park, K., Kim, H., Yu, J., Chae, H., Kim, H., & Kim, K. (2018) · Advanced Materials · doi:10.1002/adma.201704680 · Cited by 244
Fluids and Electrolytes under Confinement in Single-Digit Nanopores
Aluru, N. R., Aydin, F., Bazant, M. Z., Blankschtein, D., Brozena, A. H., de Souza, J. P., Elimelech, M., Faucher, S., Fourkas, J. T., Koman, V. B., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00155 · Cited by 224
Yuan, W., Chen, J., & Shi, G. (2014) · Materials Today · doi:10.1016/j.mattod.2014.01.021 · Cited by 201
MicroRNA Detection: Current Technology and Research Strategies
Hunt, E. A., Broyles, D., Head, T., & Deo, S. K. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040343 · Cited by 190
Nanopore sequencing data analysis: state of the art, applications and challenges
Magi, A., Semeraro, R., Mingrino, A., Giusti, B., & D’Aurizio, R. (2017) · Briefings in Bioinformatics · doi:10.1093/bib/bbx062 · Cited by 158
Metadata
- Authors
- Haque, F., Li, J., Wu, H.-C., Liang, X.-J., & Guo, P.
- Venue
- Nano Today
- Publisher
- Elsevier BV
- Published
- 2013-02
- Volume
- 8
- Issue
- 1
- Pages
- 56-74
- ISSN
- 1748-0132 (ISSN-L)
- OpenAlex
- W2143789454
- Cited by
- 421
- References
- 97
- FWCI
- 20.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.