The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Retinal vessel segmentation of color fundus images using multiscale convolutional neural network with an improved cross-entropy loss function
Abstract
Abstract Retinal vessel analysis of fundus images is an indispensable method for the screening and diagnosis of related diseases. In this paper, we propose a novel retinal vessel segmentation method of the fundus images based on convolutional neural network (CNN) and fully connected conditional random fields (CRFs). The segmentation process is mainly divided into two steps. Firstly, a multiscale CNN architecture with an improved cross-entropy loss function is proposed to produce the probability map from image to image. We construct the multiscale network by combining the feature map of each middle layer to learn more detail information of the retinal vessels. Meanwhile, our proposed cross-entropy loss function ignores the slightest loss of relatively easy samples in order to take more attention to learn the hard examples. Secondly, CRFs is applied to get the final binary segmentation result which makes use of more spatial context information by taking into account the interactions among all of the pixels in the fundus images. The effectiveness of the proposed method has been evaluated on two public datasets, i.g., DRIVE and STARE with comparisons against eleven state-of-the-art approaches including five deep learning based methods. Results show that our method allows for detection of more tiny blood vessels and more precise locating of the edges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully convolutional networks for semantic segmentation
Long, J., Shelhamer, E., & Darrell, T. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298965 · Cited by 38,834
Chen, L.-C., Papandreou, G., Kokkinos, I., Murphy, K., & Yuille, A. L. (2016) · arXiv · doi:10.48550/arxiv.1606.00915 · Cited by 22,392
Chen, L.-C., Papandreou, G., Kokkinos, I., Murphy, K., & Yuille, A. L. (2018) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2017.2699184 · Cited by 22,392
Proceedings of IEEE Conference on Computer Vision and Pattern Recognition
(1993) · doi:10.1109/cvpr.1993 · Cited by 17,667
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Efficient Inference in Fully Connected CRFs with Gaussian Edge Potentials
Krähenbühl, P., & Koltun, V. (2012) · arXiv · doi:10.48550/arxiv.1210.5644 · Cited by 2,908
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Proceedings of the International Joint Conference on Neural Networks, 2003.
(2003) · doi:10.1109/ijcnn.2003 · Cited by 1,674
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879967 · Cited by 1,497
Cited by
A review of the application of deep learning in medical image classification and segmentation
Cai, L., Gao, J., & Zhao, D. (2020) · Annals of Translational Medicine · doi:10.21037/atm.2020.02.44 · Cited by 587
associated_data_Investigating the Effectiveness of clDice Loss for Road Crack Segmentation
Pereira, V. (2025) · arXiv (Cornell University) · doi:10.5281/zenodo.15696262 · Cited by 548
Applications of deep learning in fundus images: A review
Li, T., Bo, W., Hu, C., Kang, H., Liu, H., Wang, K., & Fu, H. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.101971 · Cited by 396
Lightweight Attention Convolutional Neural Network for Retinal Vessel Image Segmentation
Li, X., Jiang, Y., Li, M., & Yin, S. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.2993842 · Cited by 265
Hu, K., Gan, Q., Zhang, Y., Deng, S., Xiao, F., Huang, W., Cao, C., & Gao, X. (2019) · IEEE Access · doi:10.1109/access.2019.2927433 · Cited by 188
Self-citation
Metadata
- Authors
- Hu, K., Zhang, Z., Niu, X., Zhang, Y., Cao, C., Xiao, F., & Gao, X.
- Venue
- Neurocomputing
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 309
- Pages
- 179-191
- ISSN
- 0925-2312 (ISSN-L)
- OpenAlex
- W2801013643
- Cited by
- 349
- References
- 35
- FWCI
- 24.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Retinal vessel segmentation of color fundus images using multiscale convolutional neural network with an improved cross-entropy loss function. https://app.cochat.ai/papers/10.1016/j.neucom.2018.05.011
- The paper
- Hu, K., Zhang, Z., Niu, X., Zhang, Y., Cao, C., Xiao, F., & Gao, X. (2018). Retinal vessel segmentation of color fundus images using multiscale convolutional neural network with an improved cross-entropy loss function. Neurocomputing. https://doi.org/10.1016/j.neucom.2018.05.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.