Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 199

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

An empirical Bayesian solution to the source reconstruction problem in EEG

Open access
Phillips, Christophe, Mattout, Jeremie, Rugg, Michael D., Maquet, Pierre, Friston, Karl J. · 2005 · NeuroImage

Abstract

Distributed linear solutions of the EEG source localisation problem are used routinely. In contrast to discrete dipole equivalent models, distributed linear solutions do not assume a fixed number of active sources and rest on a discretised fully 3D representation of the electrical activity of the brain. The ensuing inverse problem is underdetermined and constraints or priors are required to ensure the uniqueness of the solution. In a Bayesian framework, the conditional expectation of the source distribution, given the data, is attained by carefully balancing the minimisation of the residuals induced by noise and the improbability of the estimates as determined by their priors. This balance is specified by hyperparameters that control the relative importance of fitting and conforming to various constraints. Here we formulate the conventional "Weighted Minimum Norm" (WMN) solution in terms of hierarchical linear models. An "Expectation-Maximisation" (EM) algorithm is used to obtain a "Restricted Maximum Likelihood" (ReML) estimate of the hyperparameters, before estimating the "Maximum a Posteriori" solution itself. This procedure can be considered a generalisation of previous work that encompasses multiple constraints. Our approach was compared with the "classic" WMN and Maximum Smoothness solutions, using a simplified 2D source model with synthetic noisy data. The ReML solution was assessed with four types of source location priors: no priors, accurate priors, inaccurate priors, and both accurate and inaccurate priors. The ReML approach proved useful as: (1) The regularisation (or influence of the a priori source covariance) increased as the noise level increased. (2) The localisation error (LE) was negligible when accurate location priors were used. (3) When accurate and inaccurate location priors were used simultaneously, the solution was not influenced by the inaccurate priors. The ReML solution was then applied to real somatosensory-evoked responses to illustrate the application in an empirical setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2004.10.030

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 199

Metadata

Authors
Phillips, C., Mattout, J., Rugg, M. D., Maquet, P., & Friston, K. J.
Venue
NeuroImage
Publisher
Elsevier BV
Published
2005-02
Volume
24
Issue
4
Pages
997-1011
ISSN
1053-8119 (ISSN-L)
OpenAlex
W1977463519
Cited by
199
References
4
FWCI
7.16
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An empirical Bayesian solution to the source reconstruction problem in EEG. https://app.cochat.ai/papers/10.1016/j.neuroimage.2004.10.030
The paper
Phillips, C., Mattout, J., Rugg, M. D., Maquet, P., & Friston, K. J. (2005). An empirical Bayesian solution to the source reconstruction problem in EEG. NeuroImage. https://doi.org/10.1016/j.neuroimage.2004.10.030

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.