The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Quantification of the benefit from integrating MEG and EEG data in minimum ℓ2-norm estimation
Abstract
Source current estimation from electromagnetic (MEG and EEG) signals is an ill-posed problem that often produces blurry or inaccurately positioned estimates. The two modalities have distinct factors limiting the resolution, e.g., MEG cannot detect radially oriented sources, while EEG is sensitive to accuracy of the head model. This makes combined EEG+MEG estimation techniques desirable, but different acquisition noise statistics, complexity of the head models, and lack of pertinent metrics all complicate the assessment of the resulting improvements. We investigated analytically the effect of including EEG recordings in MEG studies versus the addition of new MEG channels when computing noise-normalized minimum l(2)-norm estimates. Three-compartment boundary-element forward models were constructed using structural MRI scans for four subjects. Singular value analysis of the resulting forward models predicted better performance of the EEG+MEG case in the form of higher matrix rank. MNE inverse operators for EEG, MEG and EEG+MEG were constructed using the sensor noise covariance estimated from data. Metrics derived from the resolution matrices predicted higher spatial resolution in EEG+MEG as compared to MEG due to decreased spread (lower spatial dispersion, higher resolution index) with no reduction in dipole localization error. The effect was apparent in all source locations, with increased magnitude for deep areas such as the cingulate cortex. We were also able to corroborate the results for the somatosensory cortex using median nerve responses.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Cortical Surface-Based Analysis
Fischl, B., Sereno, M. I., & Dale, A. M. (1999) · NeuroImage · doi:10.1006/nimg.1998.0396 · Cited by 6,147
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Self-citationGeophysical data analysis : discrete inverse theory
Menke, W. H. (1989) · Cited by 2,843
Dynamic Statistical Parametric Mapping
Dale, A. M., Liu, A. K., Fischl, B. R., Buckner, R. L., Belliveau, J. W., Lewine, J. D., & Halgren, E. (2000) · Neuron · doi:10.1016/s0896-6273(00)81138-1 · Cited by 1,787
Fischl, B. R., Liu, A., & Dale, A. M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906426 · Cited by 1,755
Geophysical Data Analysis: Discrete Inverse Theory
(1989) · International geophysics/International geophysics series · doi:10.1016/s0074-6142(08)x6008-5 · Cited by 1,291
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
Self-citationHelmholtz, H. (1853) · Annalen der Physik · doi:10.1002/andp.18531650603 · Cited by 989
Signal-space projection method for separating MEG or EEG into components
Uusitalo, M. A., & Ilmoniemi, R. J. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02534144 · Cited by 938
Lin, F., Witzel, T., Ahlfors, S. P., Stufflebeam, S. M., Belliveau, J. W., & Hämäläinen, M. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.054 · Cited by 506
Self-citationMurakami, S., & Okada, Y. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.105379 · Cited by 395
Monte Carlo simulation studies of EEG and MEG localization accuracy
Liu, A. K., Dale, A. M., & Belliveau, J. W. (2002) · Human Brain Mapping · doi:10.1002/hbm.10024 · Cited by 348
Demonstration of useful differences between magnetoencephalogram and electroencephalogram
Cohen, D., & Cuffin, B. N. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90005-6 · Cited by 300
Distributed current estimates using cortical orientation constraints
Lin, F., Belliveau, J. W., Dale, A. M., & Hämäläinen, M. (2005) · Human Brain Mapping · doi:10.1002/hbm.20155 · Cited by 291
Self-citationNeuronal Generators and the Problem of Localization in Electroencephalography
GLOOR, P. (1985) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-198510000-00002 · Cited by 245
The advantage of combining MEG and EEG: Comparison to fMRI in focally stimulated visual cortex
Sharon, D., Hämäläinen, M., Tootell, R. B. H., Halgren, E., & Belliveau, J. W. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.03.066 · Cited by 212
Self-citationBrain Function and Neurophysiological Correlates of Signals Used in Functional Neuroimaging
Lauritzen, M., & Gold, L. (2003) · Journal of Neuroscience · doi:10.1523/jneurosci.23-10-03972.2003 · Cited by 187
Optimization of optode arrangements for diffuse optical tomography: A singular-value analysis
Culver, J. P., Ntziachristos, V., Holboke, M. J., & Yodh, A. G. (2001) · Optics Letters · doi:10.1364/ol.26.000701 · Cited by 184
Combined MEG and EEG source imaging by minimization of mutual information
Baillet, S., Garnero, L., Marin, G., & Hugonin, J. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.759053 · Cited by 111
A novel integrated MEG and EEG analysis method for dipolar sources
Huang, M., Song, T., Hagler, D. J., Podgorny, I. A., Jousmäki, V., Cui, L., Gaa, K. M., Harrington, D. L., Dale, A. M., Lee, R. R., et al. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.06.002 · Cited by 106
Linear inverse source estimate of combined EEG and MEG data related to voluntary movements
Babiloni, F., Carducci, F., Febo Cincotti, A., Gratta, C. D., Pizzella, V., Romani, G. L., Rossini, P. M., Tecchio, F., & Babiloni, C. (2001) · Human Brain Mapping · doi:10.1002/hbm.1052 · Cited by 93
Experimental analysis of distortion of magnetoencephalography signals by the skull.
Okada, Y., Lähteenmäki, A., & Xu, C.-B. (1999) · Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00099-6 · Cited by 92
Graves, E. E., Culver, J. P., Ripoll, J., Weissleder, R., & Ntziachristos, V. (2004) · Journal of the Optical Society of America A · doi:10.1364/josaa.21.000231 · Cited by 88
Benefit of Simultaneous Recording of EEG and MEG in Dipole Localization
Yoshinaga, H., Nakahori, T., Ohtsuka, Y., Oka, E., Kitamura, Y., Kiriyama, H., Kinugasa, K., Miyamoto, K., & Hoshida, T. (2002) · Epilepsia · doi:10.1046/j.1528-1157.2002.42901.x · Cited by 65
Babiloni, F., Babiloni, C., Carducci, F., Romani, G. L., Rossini, P. M., Angelone, L. M., & Febo Cincotti, A. (2004) · Human Brain Mapping · doi:10.1002/hbm.20011 · Cited by 52
Simultaneous MEG and EEG source analysis
Huizenga, H. M., van Zuijen, T. L., Heslenfeld, D. J., & Molenaar, P. C. M. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/7/301 · Cited by 45
A method for combining MEG and EEG to determine the sources
Cohen, D., & Cuffin, B. N. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/013 · Cited by 42
Figures of merit to compare distributed linear inverse solutions
Menéndez, R. G. D. P., Andino, S. L. G., & Lütkenhöner, B. (1996) · Brain Topography · doi:10.1007/bf01200711 · Cited by 41
Cited by
Sorted by citations
Good practice for conducting and reporting MEG research
Groß, J., Baillet, S., Barnes, G. R., Henson, R. N., Hillebrand, A., Jensen, O. B., Jerbi, K., Vladimir Litvak, A., Maeß, B., Oostenveld, R., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.001 · Cited by 750
Predictive top-down integration of prior knowledge during speech perception
Sohoglu, E., Peelle, J. E., Carlyon, R. P., & Davis, M. H. (2012) · Journal of Neuroscience · doi:10.1523/jneurosci.5069-11.2012 · Cited by 388
Measuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296
“To evaluate the differences between the arrays in linear distributed-source estimation, we used metrics derived from the resolution matrix (Hauk et al., 2011; Liu et al., 2002; Molins et al., 2008; de Peralta Menendez et al., 1997; Stenroos and Hauk, 2013).”
Electrophysiological source imaging: A noninvasive window to brain dynamics
He, B., Sohrabpour, A., Brown, E., & Liu, Z. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-120853 · Cited by 297
Self-citationTracking brain states under general anesthesia by using global coherence analysis
Cimenser, A., Purdon, P. L., Pierce, E. T., Walsh, J. L., Salazar-Gómez, A. F., Harrell, P. G., Tavares, C. L., Habeeb, K., & Brown, E. N. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1017041108 · Cited by 249
Self-citation
Metadata
- Authors
- Molins, A., Stufflebeam, S. M., Brown, E. N., & Hämäläinen, M. S.
- Affiliations
- Massachusetts General Hospital (US)
- Harvard University (US)
- Corresponding author
- Molins, A.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2008-09
- Volume
- 42
- Issue
- 3
- Pages
- 1069-1077
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2007891950
- Cited by
- 192
- References
- 29
- Citations by year
- 2026: 4 · 2025: 11 · 2024: 14 · 2023: 12 · 2022: 9 · 2021: 11 · 2020: 10 · 2019: 15 · 2018: 14 · 2017: 9 · 2016: 13 · 2015: 8 · 2014: 9 · 2013: 17 · 2012: 16
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- NeuroImage (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (DP1OD003646)
- National Institute of Mental Health (K08MH067966)
- National Institute on Drug Abuse (R01DA015644)
- National Institute of Biomedical Imaging and Bioengineering (R01 EB06385, R01EB006385)
- National Center for Research Resources (P41-RR-14075, P41RR014075)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Physical Sciences › Computer Science › Signal Processing › Direction-of-Arrival Estimation Techniques
- Keywords
- inverse problems, forward model, singular value analysis, resolution matrix, spatial resolution, dipole source localization, cingulate cortex, somatosensory cortex, boundary element model
- MeSH terms
- Adolescent, Adult, Brain, Brain Mapping, Electroencephalography, Epilepsy, Humans, Signal Processing, Computer-Assisted, Magnetoencephalography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review