The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Registration based cortical thickness measurement
Open accessAbstract
Cortical thickness is an important biomarker for image-based studies of the brain. A Diffeomorphic registration based cortical thickness (DiReCT) measure is introduced where a continuous one-to-one correspondence between the gray matter-white matter interface and the estimated gray matter-cerebrospinal fluid interface is given by a Diffeomorphic mapping in the image space. Thickness is then defined in terms of a distance measure between the interfaces of this sheet like structure. This technique also provides a natural way to compute continuous estimates of thickness within buried sulci by preventing opposing gray matter banks from intersecting. In addition, the proposed method incorporates neuroanatomical constraints on thickness values as part of the mapping process. Evaluation of this method is presented on synthetic images. As an application to brain images, a longitudinal study of thickness change in frontotemporal dementia (FTD) spectrum disorder is reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868
Self-citationThinning of the Cerebral Cortex in Aging
Salat, D. H. (2004) · Cerebral Cortex · doi:10.1093/cercor/bhh032 · Cited by 1,851
Han, X., Jovicich, J., Salat, D., van der Kouwe, A., Quinn, B., Czanner, S., Busa, E., Pacheco, J., Albert, M., Killiany, R., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.051 · Cited by 1,508
Variational problems on flows of diffeomorphisms for image matching
Dupuis, P., Grenander, U., & Miller, M. I. (1998) · Quarterly of Applied Mathematics · doi:10.1090/qam/1632326 · Cited by 447
Measurement of cortical thickness using an automated 3-D algorithm: a validation study
Kabani, N., Le Goualher, G., MacDonald, D., & Evans, A. C. (2001) · NeuroImage · doi:10.1006/nimg.2000.0652 · Cited by 250
Cited by
Harmonization of cortical thickness measurements across scanners and sites
Fortin, J.-P., Cullen, N., Sheline, Y. I., Taylor, W. D., Aselcioglu, I., Cook, P. A., Adams, P., Cooper, C., Fava, M., McGrath, P. J., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.024 · Cited by 1,580
Advanced Normalization Tools (ANTs)
Avants, B. (2020) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.5138158 · Cited by 982
Self-citationCortical thickness and central surface estimation
Dahnke, R., Yotter, R. A., & Gaser, C. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.050 · Cited by 709
Large-scale evaluation of ANTs and FreeSurfer cortical thickness measurements
Tustison, N. J., Cook, P. A., Klein, A., Song, G., Das, S. R., Duda, J. T., Kandel, B. M., van Strien, N., Stone, J. R., Gee, J. C., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.05.044 · Cited by 670
Self-citationAdvanced Normalization Tools: V1.0
Avants, B., Tustison, N. J., & Song, G. (2009) · The Insight Journal · doi:10.54294/uvnhin · Cited by 559
Self-citation
Metadata
- Authors
- Das, S. R., Avants, B. B., Grossman, M., & Gee, J. C.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2009-04
- Volume
- 45
- Issue
- 3
- Pages
- 867-879
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2138728868
- Cited by
- 244
- References
- 5
- FWCI
- 7.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Registration based cortical thickness measurement. https://app.cochat.ai/papers/10.1016/j.neuroimage.2008.12.016
- The paper
- Das, S. R., Avants, B. B., Grossman, M., & Gee, J. C. (2009). Registration based cortical thickness measurement. NeuroImage. https://doi.org/10.1016/j.neuroimage.2008.12.016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.