Model-based automatic detection of the anterior and posterior commissures on MRI scans
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The projections of the anterior and posterior commissures (AC/PC) on the mid-sagittal plane of the human brain are important landmarks in neuroimaging. They can be used, for example, during MRI scanning for acquiring the imaging sections in a standard orientation. In post-acquisition image processing, these landmarks serve to establish an anatomically-based frame of reference within the brain that can be extremely useful in designing automated image analysis algorithms such as image segmentation and registration methods. This paper presents a fully automatic model-based algorithm for AC/PC detection on MRI scans. The algorithm utilizes information from a number of model images on which the locations of the AC/PC and a reference point (the vertex of the superior pontine sulcus) are known. This information is then used to locate the landmarks on test scans by template matching. The algorithm is designed to be fast, robust, and accurate. The method is flexible in that it can be trained to work on different image contrasts, optimized for different populations, or scanning modes. To assess the effectiveness of this technique, we compared automatically and manually detected landmark locations on 84 T1-weighted and 42 T2-weighted test scans. Overall, the average Euclidean distance between automatically and manually detected landmarks was 1.1 mm. A software implementation of the algorithm is freely available online at www.nitrc.org/projects/art.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227
Self-citation
Cited by
The neurocognitive consequences of sleep restriction: A meta-analytic review
Lowe, C. J., Safati, A., & Hall, P. A. (2017) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2017.07.010 · Cited by 520
Analysis of the MIRIAD Data Shows Sex Differences in Hippocampal Atrophy Progression
Ardekani, B. A., Convit, A., & Bachman, A. H. (2016) · Journal of Alzheimer's Disease · doi:10.3233/jad-150780 · Cited by 141
Self-citationCorticostriatal Circuits Encode the Subjective Value of Perceived Control
Wang, K. S., & Delgado, M. R. (2019) · Cerebral Cortex · doi:10.1093/cercor/bhz045 · Cited by 42
Metadata
- Authors
- Ardekani, B. A., & Bachman, A. H.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2009-07
- Volume
- 46
- Issue
- 3
- Pages
- 677-682
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2006333721
- Cited by
- 110
- References
- 1
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Model-based automatic detection of the anterior and posterior commissures on MRI scans. https://app.cochat.ai/papers/10.1016/j.neuroimage.2009.02.030
- The paper
- Ardekani, B. A., & Bachman, A. H. (2009). Model-based automatic detection of the anterior and posterior commissures on MRI scans. NeuroImage. https://doi.org/10.1016/j.neuroimage.2009.02.030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.