CoChat

Effects of hardware heterogeneity on the performance of SVM Alzheimer's disease classifier

Open access
Abdulkadir, Ahmed, Mortamet, Bénédicte, Vemuri, Prashanthi, Jack, Clifford R., Krueger, Gunnar, Klöppel, Stefan · 2011 · NeuroImage
Cited by 88

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Fully automated machine learning methods based on structural magnetic resonance imaging (MRI) data can assist radiologists in the diagnosis of Alzheimer’s disease (AD). These algorithms require large data sets to learn the separation of subjects with and without AD. Training and test data may come from heterogeneous hardware settings, which can potentially affect the performance of disease classification. A total of 518 MRI sessions from 226 healthy controls and 191 individuals with probable AD from the multicenter Alzheimer’s Disease Neuroimaging Initiative (ADNI) were used to investigate whether grouping data by acquisition hardware (i.e. vendor, field strength, coil system) is beneficial for the performance of a support vector machine (SVM) classifier, compared to the case where data from different hardware is mixed. We compared the change of the SVM decision value resulting from (a) changes in hardware against the effect of disease and (b) changes resulting simply from rescanning the same subject on the same machine. Maximum accuracy of 87% was obtained with a training set of all 417 subjects. Classifiers trained with 95 subjects in each diagnostic group and acquired with heterogeneous scanner settings had an empirical detection accuracy of 84.2±2.4% when tested on an independent set of the same size. These results mirror the accuracy reported in recent studies. Encouragingly, classifiers trained on images acquired with homogenous and heterogeneous hardware settings had equivalent cross-validation performances. Two scans of the same subject acquired on the same machine had very similar decision values and were generally classified into the same group. Higher variation was introduced when two acquisitions of the same subject were performed on two scanners with different field strengths. The variation was unbiased and similar for both diagnostic groups. The findings of the study encourage the pooling of data from different sites to increase the number of training samples and thereby improving performance of disease classifiers. Although small, a change in hardware could lead to a change of the decision value and thus diagnostic grouping. The findings of this study provide estimators for diagnostic accuracy of an automated disease diagnosis method involving scans acquired with different sets of hardware. Furthermore, we show that the level of confidence in the performance estimation significantly depends on the size of the training sample, and hence should be taken into account in a clinical setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2011.06.029

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 88

Metadata

Authors
Abdulkadir, A., Mortamet, B., Vemuri, P., Jack, C. R., Krueger, G., & Klöppel, S.
Venue
NeuroImage
Publisher
Elsevier BV
Published
2011-10
Volume
58
Issue
3
Pages
785-792
ISSN
1053-8119 (ISSN-L)
OpenAlex
W2094637188
Cited by
88
References
7
FWCI
4.73
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of hardware heterogeneity on the performance of SVM Alzheimer's disease classifier. https://app.cochat.ai/papers/10.1016/j.neuroimage.2011.06.029
The paper
Abdulkadir, A., Mortamet, B., Vemuri, P., Jack, C. R., Krueger, G., & Klöppel, S. (2011). Effects of hardware heterogeneity on the performance of SVM Alzheimer's disease classifier. NeuroImage. https://doi.org/10.1016/j.neuroimage.2011.06.029

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.