Identification and characterisation of midbrain nuclei using optimised functional magnetic resonance imaging
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Localising activity in the human midbrain with conventional functional MRI (fMRI) is challenging because the midbrain nuclei are small and located in an area that is prone to physiological artefacts. Here we present a replicable and automated method to improve the detection and localisation of midbrain fMRI signals. We designed a visual fMRI task that was predicted would activate the superior colliculi (SC) bilaterally. A limited number of coronal slices were scanned, orientated along the long axis of the brainstem, whilst simultaneously recording cardiac and respiratory traces. A novel anatomical registration pathway was used to optimise the localisation of the small midbrain nuclei in stereotactic space. Two additional structural scans were used to improve registration between functional and structural T1-weighted images: an echo-planar image (EPI) that matched the functional data but had whole-brain coverage, and a whole-brain T2-weighted image. This pathway was compared to conventional registration pathways, and was shown to significantly improve midbrain registration. To reduce the physiological artefacts in the functional data, we estimated and removed structured noise using a modified version of a previously described physiological noise model (PNM). Whereas a conventional analysis revealed only unilateral SC activity, the PNM analysis revealed the predicted bilateral activity. We demonstrate that these methods improve the measurement of a biologically plausible fMRI signal. Moreover they could be used to investigate the function of other midbrain nuclei.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Endogenous Pain Control Systems: Brainstem Spinal Pathways and Endorphin Circuitry
Basbaum, A. I., & Fields, H. L. (1984) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.07.030184.001521 · Cited by 2,687
Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227
The intrinsic signal-to-noise ratio in NMR imaging
Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030413 · Cited by 758
Wittmann, B. C., Schott, B. H., Guderian, S., Frey, J. U., Heinze, H.-J., & Düzel, E. (2005) · Neuron · doi:10.1016/j.neuron.2005.01.010 · Cited by 698 · cited 1×
“, 2011), or conventional fMRI (Aron et al., 2004; Chase and Clark, 2010; Murray et al., 2008; Waltz et al., 2009; Wittmann et al., 2005).”
BOLD responses reflecting dopaminergic signals in the human ventral tegmental area
D'Ardenne, K., McClure, S. M., Nystrom, L. E., & Cohen, J. D. (2008) · Science · doi:10.1126/science.1150605 · Cited by 661
Imaging attentional modulation of pain in the periaqueductal gray in humans
Tracey, I., Ploghaus, A., Gati, J. S., Clare, S., Smith, S., Menon, R. S., & Matthews, P. M. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-07-02748.2002 · Cited by 569
Substantia nigra/ventral tegmental reward prediction error disruption in psychosis
Murray, G. K., Corlett, P. R., Clark, L., Pessiglione, M., Blackwell, A. D., Honey, G., Jones, P. B., Bullmore, E. T., Robbins, T. W., & Fletcher, P. C. (2008) · Molecular Psychiatry · doi:10.1038/sj.mp.4002058 · Cited by 532 · cited 1×
“, 2011), or conventional fMRI (Aron et al., 2004; Chase and Clark, 2010; Murray et al., 2008; Waltz et al., 2009; Wittmann et al., 2005).”
Guitart-Masip, M., Fuentemilla, L., Bach, D. R., Huys, Q. J. M., Dayan, P., Dolan, R. J., & Duzel, E. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.6376-10.2011 · Cited by 216 · cited 1×
“, 2008), RETROICOR (Guitart-Masip et al., 2011), or conventional fMRI (Aron et al.”
Waltz, J. A., Schweitzer, J. B., Gold, J. M., Kurup, P. K., Ross, T. J., Jo Salmeron, B., Rose, E. J., McClure, S. M., & Stein, E. A. (2009) · Neuropsychopharmacology · doi:10.1038/npp.2008.214 · Cited by 186
Cited by
Neuroimaging of the periaqueductal gray: State of the field
Linnman, C., Moulton, E. A., Barmettler, G., Becerra, L., & Borsook, D. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.095 · Cited by 393
Ham, T., Leff, A., de Boissezon, X., Joffe, A., & Sharp, D. J. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.4692-12.2013 · Cited by 271
Limbrick-Oldfield, E. H., van Holst, R. J., & Clark, L. (2013) · NeuroImage: Clinical · doi:10.1016/j.nicl.2013.02.005 · Cited by 143
Self-citationMidbrain fMRI: Applications, Limitations and Challenges
Düzel, E., Guitart-Masip, M., Maass, A., Hämmerer, D., Betts, M. J., Speck, O., Weiskopf, N., & Kanowski, M. (2015) · Biological Magnetic Resonance · doi:10.1007/978-1-4899-7591-1_20 · Cited by 16
Metadata
- Authors
- Limbrick-Oldfield, E. H., Brooks, J. C. W., Wise, R. J. S., Padormo, F., Hajnal, J. V., Beckmann, C. F., & Ungless, M. A.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2012-01
- Volume
- 59
- Issue
- 2
- Pages
- 1230-1238
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2094214406
- Cited by
- 46
- References
- 9
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identification and characterisation of midbrain nuclei using optimised functional magnetic resonance imaging. https://app.cochat.ai/papers/10.1016/j.neuroimage.2011.08.016
- The paper
- Limbrick-Oldfield, E. H., Brooks, J. C. W., Wise, R. J. S., Padormo, F., Hajnal, J. V., Beckmann, C. F., & Ungless, M. A. (2012). Identification and characterisation of midbrain nuclei using optimised functional magnetic resonance imaging. NeuroImage. https://doi.org/10.1016/j.neuroimage.2011.08.016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.