LCC-Demons: A robust and accurate symmetric diffeomorphic registration algorithm
Open accessThe DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Abstract
Non-linear registration is a key instrument for computational anatomy to study the morphology of organs and tissues. However, in order to be an effective instrument for the clinical practice, registration algorithms must be computationally efficient, accurate and most importantly robust to the multiple biases affecting medical images. In this work we propose a fast and robust registration framework based on the log-Demons diffeomorphic registration algorithm. The transformation is parameterized by stationary velocity fields (SVFs), and the similarity metric implements a symmetric local correlation coefficient (LCC). Moreover, we show how the SVF setting provides a stable and consistent numerical scheme for the computation of the Jacobian determinant and the flux of the deformation across the boundaries of a given region. Thus, it provides a robust evaluation of spatial changes. We tested the LCC-Demons in the inter-subject registration setting, by comparing with state-of-the-art registration algorithms on public available datasets, and in the intra-subject longitudinal registration problem, for the statistically powered measurements of the longitudinal atrophy in Alzheimer's disease. Experimental results show that LCC-Demons is a generic, flexible, efficient and robust algorithm for the accurate non-linear registration of images, which can find several applications in the field of medical imaging. Without any additional optimization, it solves equally well intra & inter-subject registration problems, and compares favorably to state-of-the-art methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496 · cited 1×
“In our experiments we computed the gray-white matter tissue mask with an automated procedure based on the FSL package tools for the automatic brain extraction and the tissue class segmentation [46, 40].”
MethodVoxel-Based Morphometry—The Methods
Ashburner, J., & Friston, K. J. (2000) · NeuroImage · doi:10.1006/nimg.2000.0582 · Cited by 8,676 · cited 4×
“, 2001), the voxel/tensor-based morphometry based on the Jacobian determinant of the deformation (VBM, TBM) (Ashburner and Friston, 2000; Riddle et al., 2004), the RAVENS maps (Resnik et al.”
BackgroundInfluentialA fast diffeomorphic image registration algorithm
Ashburner, J. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.007 · Cited by 8,122
N4ITK: Improved N3 Bias Correction
Tustison, N. J., Avants, B. B., Cook, P. A., Zheng, Y., Egan, A., Yushkevich, P. A., & Gee, J. C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2046908 · Cited by 6,073 · cited 2×
“Bias correction is often performed prior to image registration in order to remove global intensity inhomogeneity (Hou, 2006; Sled et al., 1998; Tustison et al., 2010), but this is often not sufficient to remove local changes in the bias field.”
BackgroundAVANTS, B., EPSTEIN, C., GROSSMAN, M., & GEE, J. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.06.004 · Cited by 5,669 · cited 1×
“The local correlation coefficient (or local cross correlation) is based on the implicit estimation of the local affine scaling parameters of the intensities (additive plus multiplicative), and was later used in several successful registration algorithms as a good trade-off between the SSD, in which there are no hidden…”
MethodA nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 1×
“Bias correction is often performed prior to image registration in order to remove global intensity inhomogeneity (Hou, 2006; Sled et al., 1998; Tustison et al., 2010), but this is often not sufficient to remove local changes in the bias field.”
BackgroundMultimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 1×
“For instance the (normalized) correlation criteria assumes a global affine relationship between the intensities in the images, to account for global multiplicative and additive bias [16, 14], while the (normalized) mutual information (NMI) does not require any parametric assumption on the relationship between the inte…”
BackgroundA Bayesian model of shape and appearance for subcortical brain segmentation
Patenaude, B., Smith, S. M., Kennedy, D. N., & Jenkinson, M. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.046 · Cited by 2,287
Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227 · cited 2×
“In order to test the LCC-Demons we replicated the registration pipeline proposed by Klein et al. (2009) on the data considered by the authors (CUMC12, MGH10, LPBA40 and IBSR12 datasets).”
MethodUnbiased nonlinear average age-appropriate brain templates from birth to adulthood
Fonov, V., Evans, A., McKinstry, R., Almli, C., & Collins, D. (2009) · NeuroImage · doi:10.1016/s1053-8119(09)70884-5 · Cited by 2,102 · cited 1×
“Within each dataset, we non-linearly registered all the possible pairs of linearly aligned images, after an initial affine registration to the MNI reference space (Fonov et al., 2009).”
Method
Cited by
Deep learning in medical image registration: a survey
Haskins, G., Kruger, U., & Yan, P. (2020) · Machine Vision and Applications · doi:10.1007/s00138-020-01060-x · Cited by 704
Weiner, M. W., Veitch, D. P., Aisen, P. S., Beckett, L. A., Cairns, N. J., Cedarbaum, J., Green, R. C., Harvey, D., Jack, C. R., Jagust, W., et al. (2015) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2014.11.001 · Cited by 348
Svf-net: learning deformable image registration using shape matching
Rohé, M.-M., Datar, M., Heimann, T., Sermesant, M., & Pennec, X. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66182-7_31 · Cited by 330
Self-citationBirnet: Brain image registration using dual-supervised fully convolutional networks
Fan, J., Cao, X., Yap, P.-T., & Shen, D. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.03.006 · Cited by 297
Deep reinforcement learning in computer vision: a comprehensive survey
Le, N., Rathour, V. S., Yamazaki, K., Luu, K., & Savvides, M. (2022) · Artificial Intelligence Review · doi:10.1007/s10462-021-10061-9 · Cited by 261
Robust non-rigid registration through agent-based action learning
Krebs, J., Mansi, T., Delingette, H., Zhang, L., Ghesu, F. C., Miao, S., Maier, A. K., Ayache, N., Liao, R., & Kamen, A. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66182-7_40 · Cited by 225
“However, on our challenging test data our method outperformed the LCC-Demons [5] algorithm with Table 1: Results of prostate MR registration on the 56 testing pairs.”
MethodResultSelf-citationAdversarial learning for mono- or multi-modal registration
Fan, J., Cao, X., Wang, Q., Yap, P.-T., & Shen, D. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101545 · Cited by 168
“, 2008), LCC-demons (Lorenzi et al., 2013), large defor- mation diffeomorphic metric mapping (LDDMM) (Cao et al.”
BackgroundMethodInfluentialDeep Learning in Medical Image Registration
Chen, X., Diaz-Pinto, A., Ravikumar, N., & Frangi, A. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/abd37c · Cited by 106
Assessing atrophy measurement techniques in dementia: results from the MIRIAD atrophy challenge
Cash, D. M., Frost, C., Iheme, L. O., Ünay, D., Kandemir, M., Fripp, J., Salvado, O., Bourgeat, P., Reuter, M., Fischl, B., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.07.087 · Cited by 72
“…et al., 2010) Within-subject (Reuter et al., 2012) Atlas (Dale et al., 1999; Fischl, 2012; Fischl et al., 2002) N/A N/A INRIAa INRIA N3 Demons-LCC (Lorenzi et al., 2013; Vercauteren et al., 2008) ADNI 200 HC Loose regions Demons-LCC Regional flux analysis (Lorenzi et al., 2015) Mayo Clinic MAYO,…”
BackgroundSelf-citationA Review of Keypoints’ Detection and Feature Description in Image Registration
Liu, C., Xu, J., & Wang, F. (2021) · Scientific Programming · doi:10.1155/2021/8509164 · Cited by 47
Metadata
- Authors
- Lorenzi, M., Ayache, N., Frisoni, G. B., & Pennec, X.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2013-11
- Volume
- 81
- Pages
- 470-483
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2077008573
- Cited by
- 162
- References
- 57
- FWCI
- 14.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.