The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Brain morphometry reproducibility in multi-center 3T MRI studies: A comparison of cross-sectional and longitudinal segmentations
Open accessAbstract
Large-scale longitudinal multi-site MRI brain morphometry studies are becoming increasingly crucial to characterize both normal and clinical population groups using fully automated segmentation tools. The test-retest reproducibility of morphometry data acquired across multiple scanning sessions, and for different MR vendors, is an important reliability indicator since it defines the sensitivity of a protocol to detect longitudinal effects in a consortium. There is very limited knowledge about how across-session reliability of morphometry estimates might be affected by different 3T MRI systems. Moreover, there is a need for optimal acquisition and analysis protocols in order to reduce sample sizes. A recent study has shown that the longitudinal FreeSurfer segmentation offers improved within session test-retest reproducibility relative to the cross-sectional segmentation at one 3T site using a nonstandard multi-echo MPRAGE sequence. In this study we implement a multi-site 3T MRI morphometry protocol based on vendor provided T1 structural sequences from different vendors (3D MPRAGE on Siemens and Philips, 3D IR-SPGR on GE) implemented in 8 sites located in 4 European countries. The protocols used mild acceleration factors (1.5-2) when possible. We acquired across-session test-retest structural data of a group of healthy elderly subjects (5 subjects per site) and compared the across-session reproducibility of two full-brain automated segmentation methods based on either longitudinal or cross-sectional FreeSurfer processing. The segmentations include cortical thickness, intracranial, ventricle and subcortical volumes. Reproducibility is evaluated as absolute changes relative to the mean (%), Dice coefficient for volume overlap and intraclass correlation coefficients across two sessions. We found that this acquisition and analysis protocol gives comparable reproducibility results to previous studies that used longer acquisitions without acceleration. We also show that the longitudinal processing is systematically more reliable across sites regardless of MRI system differences. The reproducibility errors of the longitudinal segmentations are on average approximately half of those obtained with the cross sectional analysis for all volume segmentations and for entorhinal cortical thickness. No significant differences in reliability are found between the segmentation methods for the other cortical thickness estimates. The average of two MPRAGE volumes acquired within each test-retest session did not systematically improve the across-session reproducibility of morphometry estimates. Our results extend those from previous studies that showed improved reliability of the longitudinal analysis at single sites and/or with non-standard acquisition methods. The multi-site acquisition and analysis protocol presented here is promising for clinical applications since it allows for smaller sample sizes per MRI site or shorter trials in studies evaluating the role of potential biomarkers to predict disease progression or treatment effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Desikan, R. S., Ségonne, F., Fischl, B., Quinn, B. T., Dickerson, B. C., Blacker, D., Buckner, R. L., Dale, A. M., Maguire, R. P., Hyman, B. T., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.021 · Cited by 13,324
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Voxel-Based Morphometry—The Methods
Ashburner, J., & Friston, K. J. (2000) · NeuroImage · doi:10.1006/nimg.2000.0582 · Cited by 8,676
Fischl, B., Salat, D. H., Busa, E., Albert, M., Dieterich, M., Haselgrove, C., van der Kouwe, A., Killiany, R., Kennedy, D., Klaveness, S., et al. (2002) · Neuron · doi:10.1016/s0896-6273(02)00569-x · Cited by 8,610
Within-subject template estimation for unbiased longitudinal image analysis
Reuter, M., Schmansky, N. J., Rosas, H. D., & Fischl, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.084 · Cited by 2,356
The Alzheimer's Disease Neuroimaging Initiative
Mueller, S. G., Weiner, M. W., Thal, L. J., Petersen, R. C., Jack, C., Jagust, W., Trojanowski, J. Q., Toga, A. W., & Beckett, L. (2005) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2005.09.008 · Cited by 1,525
Han, X., Jovicich, J., Salat, D., van der Kouwe, A., Quinn, B., Czanner, S., Busa, E., Pacheco, J., Albert, M., Killiany, R., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.051 · Cited by 1,508
Self-citationGrey matter differences in bipolar disorder: a meta-analysis of voxel-based morphometry studies
Selvaraj, S., Arnone, D., Job, D., Stanfield, A., Farrow, T. F., Nugent, A. C., Scherk, H., Gruber, O., Chen, X., Sachdev, P. S., et al. (2012) · Bipolar Disorders · doi:10.1111/j.1399-5618.2012.01000.x · Cited by 341
Mapping local hippocampal changes in Alzheimer's disease and normal ageing with MRI at 3 Tesla
Frisoni, G. B., Ganzola, R., Canu, E., Rub, U., Pizzini, F. B., Alessandrini, F., Zoccatelli, G., Beltramello, A., Caltagirone, C., & Thompson, P. M. (2008) · Brain · doi:10.1093/brain/awn280 · Cited by 256 · cited 1×
“As recently shown, the characterization of 3D shape of brain structures (Miller, 2004; Miller et al., 2009; Wang et al., 2007) may be used to investigate differences between subject populations (Frisoni et al., 2008, Cavedo et al., 2011).”
Self-citationAdvances in MRI for 'cryptogenic' epilepsies
Bernasconi, A., Bernasconi, N., Bernhardt, B. C., & Schrader, D. (2011) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.199 · Cited by 233 · cited 1×
“…Alzheimer's disease (Drago et al., 2011; Fjell and Walhovd, 2012; Frisoni et al., 2010; Jack, 2011), Parkinson's disease (Kostić and Filippi, 2011), autism (Chen et al., 2011), bipolar disorders (Selvaraj et al., 2012), epilepsy (Bernasconi et al., 2011) and schizophrenia (Levitt et al., 2010).”
WONDERLICK, J., ZIEGLER, D., HOSSEINIVARNAMKHASTI, P., LOCASCIO, J., BAKKOUR, A., VANDERKOUWE, A., TRIANTAFYLLOU, C., CORKIN, S., & DICKERSON, B. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.037 · Cited by 221
Structural MRI in Autism Spectrum Disorder
CHEN, R., JIAO, Y., & HERSKOVITS, E. H. (2011) · Pediatric Research · doi:10.1203/pdr.0b013e318212c2b3 · Cited by 154
Haemodialysis and cerebral oedema
Walters, R. J. L., Fox, N. C., Crum, W. R., Taube, D., & Thomas, D. J. (2001) · Nephron · doi:10.1159/000045903 · Cited by 87 · cited 2×
“, 2009), includinghydration status of the subject (Walters et al., 2001), instrument related factors such as scanner manufacturer, field strength, head RF coil, magnetic gradients (Jovicich et al.”
Alliance for aging research AD biomarkers work group: structural MRI
Jack, C. R. (2011) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2011.09.011 · Cited by 64 · cited 2×
“…(Silk and Wood, 2011), normal aging (Mueller et al., 2007), Alzheimer's disease (Drago et al., 2011; Fjell and Walhovd, 2012; Frisoni et al., 2010; Jack, 2011), Parkinson's disease (Kostić and Filippi, 2011), autism (Chen et al., 2011), bipolar disorders (Selvaraj et al., 2012), epilepsy…”
Cited by
Identification of a Common Neurobiological Substrate for Mental Illness
Goodkind, M., Eickhoff, S. B., Oathes, D. J., Jiang, Y., Chang, A., Jones-Hagata, L. B., Ortega, B. N., Zaiko, Y. V., Roach, E. L., Korgaonkar, M. S., et al. (2015) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2014.2206 · Cited by 1,404
Brain atrophy in Alzheimer’s Disease and aging
Pini, L., Pievani, M., Bocchetta, M., Altomare, D., Bosco, P., Cavedo, E., Galluzzi, S., Marizzoni, M., & Frisoni, G. B. (2016) · Ageing Research Reviews · doi:10.1016/j.arr.2016.01.002 · Cited by 836
Self-citationMindboggling morphometry of human brains
Klein, A., Ghosh, S. S., Bao, F. S., Giard, J., Häme, Y., Stavsky, E., Lee, N., Rossa, B., Reuter, M., Chaibub Neto, E., et al. (2017) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1005350 · Cited by 710
Large-scale evaluation of ANTs and FreeSurfer cortical thickness measurements
Tustison, N. J., Cook, P. A., Klein, A., Song, G., Das, S. R., Duda, J. T., Kandel, B. M., van Strien, N., Stone, J. R., Gee, J. C., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.05.044 · Cited by 670
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
“Due to the combination of high spatial resolution, good contrast, 3D capabilities, and efficient correction algorithms for source of distortions, mainly gradient non-linearities, NMR imaging is the reference method for measuring organs volume and dimensions [120, 125, 177, 277].”
Method
Metadata
- Authors
- Jovicich, J., Marizzoni, M., Sala-Llonch, R., Bosch, B., Bartrés-Faz, D., Arnold, J., Benninghoff, J., Wiltfang, J., Roccatagliata, L., Nobili, F., Hensch, T., Tränkner, A., Schönknecht, P., Leroy, M., Lopes, R., Bordet, R., Chanoine, V., Ranjeva, J.-P., Didic, M., Gros-Dagnac, H., Payoux, P., Zoccatelli, G., Alessandrini, F., Beltramello, A., Bargalló, N., Blin, O., & Frisoni, G. B.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2013-12
- Volume
- 83
- Pages
- 472-484
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2067145795
- Cited by
- 183
- References
- 15
- FWCI
- 16.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.