Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 173

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Optimization of a free water elimination two-compartment model for diffusion tensor imaging

Open access
Hoy, Andrew R., Koay, Cheng Guan, Kecskemeti, Steven R., Alexander, Andrew L.·2014·NeuroImage

Abstract

Diffusion tensor imaging is used to measure the diffusion of water in tissue. The diffusion properties carry information about the relative organization and structure of the underlying tissue. In the case of a single voxel containing both tissue and a fast diffusing component such as free water, a single diffusion tensor is no longer appropriate. A two-tensor free water elimination model has previously been proposed to correct for the case of volume mixing. Here, this model was implemented in a straightforward but novel manner without the use of spatial constraints. The optimal acquisition parameters were investigated through Monte Carlo simulations and human brain imaging studies. At a signal-to-noise ratio of 40 with 64 diffusion-weighted encoding images, the most accurate estimates of fast diffusion signal were obtained with two diffusion-weighted shells (b-value in s/mm^2 x number of directions) of 500×32 and 1500×32. The potential bias in fractional anisotropy induced by this two-compartment model was more than an order of magnitude less than the error of using the single diffusion tensor model in the presence of partial volume effects with free water. This strategy may be useful for characterizing the diffusion of tissues adjacent to cerebral spinal fluid (CSF), tissues affected by edema, and removing artifacts from blurring and ghosting of the CSF signal.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2014.09.053

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 173

Metadata

Authors
Hoy, A. R., Koay, C. G., Kecskemeti, S. R., & Alexander, A. L.
Venue
NeuroImage
Publisher
Elsevier BV
Published
2014-12
Volume
103
Pages
323-333
ISSN
1053-8119 (ISSN-L)
OpenAlex
W2084542629
Cited by
173
References
7
FWCI
3.85
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimization of a free water elimination two-compartment model for diffusion tensor imaging. https://app.cochat.ai/papers/10.1016/j.neuroimage.2014.09.053
The paper
Hoy, A. R., Koay, C. G., Kecskemeti, S. R., & Alexander, A. L. (2014). Optimization of a free water elimination two-compartment model for diffusion tensor imaging. NeuroImage. https://doi.org/10.1016/j.neuroimage.2014.09.053

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.