g-Ratio weighted imaging of the human spinal cord in vivo
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The fiber g‐ratio is defined as the ratio of the inner to the outer diameter of the myelin sheath. This ratio provides a measure of the myelin thickness that complements axon morphology (diameter and density) for assessment of demyelination in diseases such as multiple sclerosis. Previous work has shown that an aggregate g‐ratio map can be computed using a formula that combines axon and myelin density measured with quantitative MRI. In this work, we computed g‐ratio weighted maps in the cervical spinal cord of nine healthy subjects. We utilized the 300 mT/m gradients from the CONNECTOM scanner to estimate the fraction of restricted water (fr) with high accuracy, using the CHARMED model. Myelin density was estimated using the lipid and macromolecular tissue volume (MTV) method, derived from normalized proton density (PD) mapping. The variability across spinal level, laterality and subject were assessed using a three‐way ANOVA. The average g‐ratio value obtained in the white matter was 0.76+/−0.03, consistent with previous histology work. Coefficients of variation of fr and MTV were respectively 4.3% and 13.7%. fr and myelin density were significantly different across spinal tracts (p=3×10−7 and 0.004 respectively) and were positively correlated in the white matter (r=0.42), suggesting shared microstructural information. The aggregate g‐ratio did not show significant differences across tracts (p=0.6). This study suggests that fr and myelin density can be measured in vivo with high precision and that they can be combined to produce a g‐ratio‐weighted map robust to free water pool contamination from cerebrospinal fluid or veins. Potential applications include the study of early demyelination in multiple sclerosis, and the quantitative assessment of remyelination drugs. Graphical abstract Figure. No caption available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
Diffusion tensor imaging of the brain
Alexander, A. L., Lee, J. E., Lazar, M., & Field, A. S. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.011 · Cited by 2,747 · cited 1×
“diffusion tensor imaging can be caused by demyelination, axon degeneration, gliosis, edema, lower axon density or cerebrospinal fluid (CSF) contamination (Alexander et al., 2007; Metwalli et al., 2010; Saba, 2015).”
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488 · cited 1×
“More advanced diffusion MRI techniques such as diffusion kurtosis imaging (Jensen et al., 2005; Lätt et al., 2008), AxCaliber (Assaf et al.”
Free water elimination and mapping from diffusion MRI
Pasternak, O., Sochen, N., Gur, Y., Intrator, N., & Assaf, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22055 · Cited by 1,092
Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
Assaf, Y., & Basser, P. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.042 · Cited by 856 · cited 2×
“We utilized the 300 mT/m gradients from the CONNECTOM scanner for estimating the fraction of restricted water (fr) with high accuracy using the CHARMED model.”
Axcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849 · cited 2×
“For each subject, two successive protocols were used: a diffusion MRI AxCaliber protocol (Assaf et al., 2008), and a lipid and macromolecular tissue volume (MTV) protocol similar to the one used by Mezer et al.”
Orientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683
Pushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545
Self-citationElectron microscopy of oligodendroglia in severe mental illness
Uranova, N., Orlovskaya, D., Vikhreva, O., Zimina, I., Kolomeets, N., Vostrikov, V., & Rachmanova, V. (2001) · Brain Research Bulletin · doi:10.1016/s0361-9230(01)00528-7 · Cited by 495
High field MRI correlates of myelin content and axonal density in multiple sclerosis
Mottershead, J. P., Schmierer, K., Clemence, M., Thornton, J. S., Scaravilli, F., Barker, G. J., Tofts, P. S., Newcombe, J., Cuzner, M. L., Ordidge, R. J., et al. (2003) · Journal of Neurology · doi:10.1007/s00415-003-0192-3 · Cited by 296 · cited 1×
“52) in multiple sclerosis (Mottershead et al., 2003), and (iv) its relation with brain development (Saito et al.”
Cited by
SCT: Spinal Cord Toolbox, an open-source software for processing spinal cord MRI data
De Leener, B., Lévy, S., Dupont, S. M., Fonov, V. S., Stikov, N., Louis Collins, D., Callot, V., & Cohen-Adad, J. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.10.009 · Cited by 621
Self-citationDesign and Validation of Diffusion MRI Models of White Matter
Jelescu, I. O., & Budde, M. D. (2017) · Frontiers in Physics · doi:10.3389/fphy.2017.00061 · Cited by 240
“Measures of AWF have also been combined with MRI measures of myelin content to estimate myelin gratio in vivo, which compared favorably to that derived from EM [155, 156].”
MRI in traumatic spinal cord injury: from clinical assessment to neuroimaging biomarkers
Freund, P., Seif, M., Weiskopf, N., Friston, K., Fehlings, M. G., Thompson, A. J., & Curt, A. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30138-3 · Cited by 222
Promise and pitfalls of g-ratio estimation with MRI
Campbell, J. S. W., Leppert, I. R., Narayanan, S., Boudreau, M., Duval, T., Cohen-Adad, J., Pike, G. B., & Stikov, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.038 · Cited by 129
“These include a study of the effects of age and gender in a population of subjects aged 20 to 76 using qMT and NODDI (Cercignani et al., 2016b), studies of healthy adults using MTsat and the TFD (Mohammadi et al., 2015) and MTV and DTI (Berman et al., 2017), and a study of healthy subjects using the ViSTa myelin water…”
BackgroundInfluentialSelf-citationEvolution of white matter tract microstructure across the life span
Slater, D. A., Melie‐Garcia, L., Preisig, M., Kherif, F., Lutti, A., & Draganski, B. (2019) · Human Brain Mapping · doi:10.1002/hbm.24522 · Cited by 119
“PD-based estimates of the g-ratio do not require calibration (Berman et al., 2017; Duval et al., 2017) and differences arising from such a comparison might highlight changes in macromolecular content with age.”
Background
Metadata
- Authors
- Duval, T., Lévy, S., Stikov, N., Campbell, J., Mezer, A., Witzel, T., Keil, B., Smith, V., Wald, L. L., Klawiter, E., & Cohen-Adad, J.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2017-01
- Volume
- 145
- Issue
- Pt A
- Pages
- 11-23
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2523445319
- Cited by
- 69
- References
- 15
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: g-Ratio weighted imaging of the human spinal cord in vivo. https://app.cochat.ai/papers/10.1016/j.neuroimage.2016.09.018
- The paper
- Duval, T., Lévy, S., Stikov, N., Campbell, J., Mezer, A., Witzel, T., Keil, B., Smith, V., Wald, L. L., Klawiter, E., & Cohen-Adad, J. (2017). g-Ratio weighted imaging of the human spinal cord in vivo. NeuroImage. https://doi.org/10.1016/j.neuroimage.2016.09.018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.