Prospective motion correction in functional MRI
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
&NA; Due to the intrinsic low sensitivity of BOLD‐fMRI long scanning is required. Subject motion during fMRI scans reduces statistical significance of the activation maps and increases the prevalence of false activations. Motion correction is therefore an essential tool for a successful fMRI data analysis. Retrospective motion correction techniques are now commonplace and are incorporated into a wide range of fMRI analysis toolboxes. These techniques are advantageous due to robustness, sequence independence and have minimal impact on the fMRI study setup. Retrospective techniques however, do not provide an accurate intra‐volume correction, nor can these techniques correct for the spin‐history effects. The application of prospective motion correction in fMRI appears to be effective in reducing false positives and increasing sensitivity when compared to retrospective techniques, particularly in the cases of substantial motion. Especially advantageous in this regard is the combination of prospective motion correction with dynamic distortion correction. Nevertheless, none of the recent methods are able to recover activations in presence of motion that are comparable to no‐motion conditions, which motivates further research in the area of adaptive dynamic imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Spatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 4,028
Movement‐Related effects in fMRI time‐series
Friston, K. J., Williams, S., Howard, R., Frackowiak, R. S. J., & Turner, R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350312 · Cited by 3,774
Methods to detect, characterize, and remove motion artifact in resting state fMRI
Power, J. D., Mitra, A., Laumann, T. O., Snyder, A. Z., Schlaggar, B. L., & Petersen, S. E. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.08.048 · Cited by 3,748 · cited 1×
“Even after regressing out motion-relevant parameters, data censoring, commonly referred to as “scrubbing” is often necessary (Carp, 2013; Power et al., 2014).”
BackgroundThe influence of head motion on intrinsic functional connectivity MRI
Van Dijk, K. R. A., Sabuncu, M. R., & Buckner, R. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.044 · Cited by 2,344
Yan, C.-G., Cheung, B., Kelly, C., Colcombe, S., Craddock, R. C., Di Martino, A., Li, Q., Zuo, X.-N., Castellanos, F. X., & Milham, M. P. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.004 · Cited by 1,461
Goebel, R., Esposito, F., & Formisano, E. (2006) · Human Brain Mapping · doi:10.1002/hbm.20249 · Cited by 1,053
Resting-state fMRI confounds and cleanup
Murphy, K., Birn, R. M., & Bandettini, P. A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.001 · Cited by 666 · cited 1×
“In resting-state fMRI, the microscopic sub-voxel movements are a source of large concern (Murphy et al., 2013), introducing potential bias in group”
BackgroundCompensation of susceptibility-induced bold sensitivity losses in echo-planar fMRI imaging
Deichmann, R., Josephs, O., Hutton, C., Corfield, D. R., & Turner, R. (2002) · NeuroImage · doi:10.1006/nimg.2001.0985 · Cited by 253
de Bie, H. M. A., Boersma, M., Wattjes, M. P., Adriaanse, S., Vermeulen, R. J., Oostrom, K. J., Huisman, J., Veltman, D. J., & Delemarre-Van de Waal, H. A. (2010) · European Journal of Pediatrics · doi:10.1007/s00431-010-1181-z · Cited by 245
Cited by
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
“…al., 2014; Speck et al., 2006; Todd et al., 2015) or the use of dedicated sequences with navigators echoes or active markers (Hu and Kim, 1994; Lee et al., 1996; Muraskin et al., 2013; Pfeuffer et al., 2002; White et al., 2010) can be useful for prospective motion correction (Zaitsev et al., 2016).”
Advances in resting state fMRI acquisitions for functional connectomics
Raimondo, L., Oliveira, Ĺ. A. F., Heij, J., Priovoulos, N., Kundu, P., Leoni, R. F., & van der Zwaag, W. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118503 · Cited by 180
EEG-Informed fMRI: A Review of Data Analysis Methods
Abreu, R., Leal, A., & Figueiredo, P. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00029 · Cited by 171
“These estimates are typically used to improve MR image quality, by updating the specifications of the RF pulses and MR gradients during the image acquisition in real-time (recent reviews on these approaches can be found in Maclaren et al., 2013; Zaitsev et al., 2016).”
MethodCustomized head molds reduce motion during resting state fMRI scans
Power, J. D., Silver, B. M., Silverman, M. R., Ajodan, E. L., Bos, D. J., & Jones, R. M. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.01.016 · Cited by 88
Metadata
- Authors
- Zaitsev, M., Akin, B., LeVan, P., & Knowles, B. R.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2017-07
- Volume
- 154
- Pages
- 33-42
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2549129224
- Cited by
- 121
- References
- 10
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.