Inferring brain tissue composition and microstructure via MR relaxometry
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Abstract MRI relaxometry is sensitive to a variety of tissue characteristics in a complex manner, which makes it both attractive and challenging for characterizing tissue. This article reviews the most common water proton relaxometry measures, Symbol, Symbol, and Symbol, and reports on their development and current potential to probe the composition and microstructure of brain tissue. The development of these relaxometry measures is challenged by the need for suitably accurate tissue models, as well as robust acquisition and analysis methodologies. MRI relaxometry has been established as a tool for characterizing neural tissue, particular with respect to myelination, and the potential for further development exists. Symbol. No caption available. Symbol. No caption available. Symbol. No caption available. HighlightsMRI relaxometry is sensitive to brain tissue microstructure.Each of T1, T2, and T2* relaxometry can be used.Tissue models, acquisition methods, and analysis methods are important.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577 · cited 1×
“, 2004) and various model based reconstructions (Ben-Eliezer et al., 2015; Huang et al., 2013; Lankford et al., 2015; Ma et al., 2013; Sumpf et al., 2011, 2014).”
BackgroundMapping Human Cortical Areas In Vivo Based on Myelin Content as Revealed by T1- and T2-Weighted MRI
Glasser, M. F., & Van Essen, D. C. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.2180-11.2011 · Cited by 1,447
Myelin and iron concentration in the human brain: a quantitative study of MRI contrast
Stüber, C., Morawski, M., Schäfer, A., Labadie, C., Wähnert, M., Leuze, C., Streicher, M., Barapatre, N., Reimann, K., Geyer, S., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.02.026 · Cited by 635
Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology
Laule, C., Leung, E., Li, D. K., Traboulsee, A. L., Paty, D. W., MacKay, A. L., & Moore, G. R. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070928 · Cited by 489 · cited 1×
“luxol-fast-blue staining of human cadaver brain samples (Laule et al., 2006; Moore et al., 2000).”
BackgroundUsing high-resolution quantitative mapping of R1 as an index of cortical myelination
Lutti, A., Dick, F., Sereno, M. I., & Weiskopf, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.005 · Cited by 346 · cited 1×
“For a more comprehensive report on T1 relaxometry acquisitionmethods, still within the scope of brain imaging, the reader is directed to a recent review article (Lutti et al., 2014) and a report on experimental evaluations of common methods (Stikov et al.”
MethodHigh field MRI correlates of myelin content and axonal density in multiple sclerosis
Mottershead, J. P., Schmierer, K., Clemence, M., Thornton, J. S., Scaravilli, F., Barker, G. J., Tofts, P. S., Newcombe, J., Cuzner, M. L., Ordidge, R. J., et al. (2003) · Journal of Neurology · doi:10.1007/s00415-003-0192-3 · Cited by 296
On the accuracy of T1 mapping: Searching for common ground
Stikov, N., Boudreau, M., Levesque, I. R., Tardif, C. L., Barral, J. K., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25135 · Cited by 285 · cited 1×
“, 2014) and a report on experimental evaluations of common methods (Stikov et al., 2014).”
BackgroundQuantitative magnetic resonance of postmortem multiple sclerosis brain before and after fixation
Schmierer, K., Wheeler‐Kingshott, C. A. M., Tozer, D. J., Boulby, P. A., Parkes, H. G., Yousry, T. A., Scaravilli, F., Barker, G. J., Tofts, P. S., & Miller, D. H. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21487 · Cited by 281
Is diffusion anisotropy an accurate monitor of myelination?
Mädler, B., Drabycz, S. A., Kolind, S. H., Whittall, K. P., & MacKay, A. L. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.047 · Cited by 227 · cited 1×
“Although MacKay and colleagues (as well as a few others) made effective use of this MRI T2 relaxometry protocol (Kolind et al., 2008, 2009; Laule et al., 2004, 2006, 2007b,c, 2008; M€adler et al., 2008; Vavasour et al., 2009; Whittall et al., 1997), it had several shortcomings.”
BackgroundTE dependent Diffusion Imaging (TEdDI) distinguishes between compartmental T2 relaxation times
Veraart, J., Novikov, D. S., & Fieremans, E. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.09.030 · Cited by 212
Cited by
Quantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L. J., Helms, G., Mohammadi, S., & Kirilina, E. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 300
hMRI – A toolbox for quantitative MRI in neuroscience and clinical research
Tabelow, K., Balteau, E., Ashburner, J., Callaghan, M. F., Draganski, B., Helms, G., Kherif, F., Leutritz, T., Lutti, A., Phillips, C., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.01.029 · Cited by 256
Iron, myelin, and the brain: neuroimaging meets neurobiology
Möller, H. E., Bossoni, L., Connor, J. R., Crichton, R. R., Does, M. D., Ward, R. J., Zecca, L., Zucca, F. A., & Ronen, I. (2019) · Trends in Neurosciences · doi:10.1016/j.tins.2019.03.009 · Cited by 207
Self-citationLazari, A., & Lipp, I. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117744 · Cited by 197
An interactive meta-analysis of MRI biomarkers of myelin
Mancini, M., Karakuzu, A., Cohen-Adad, J., Cercignani, M., Nichols, T. E., & Stikov, N. (2020) · eLife · doi:10.7554/elife.61523 · Cited by 168
So You Want to Image Myelin Using MRI: An Overview and Practical Guide for Myelin Water Imaging
Lee, J., Hyun, J., Lee, J., Choi, E., Shin, H., Min, K., Nam, Y., Kim, H. J., & Oh, S. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27059 · Cited by 134
Microstructural imaging in the spinal cord and validation strategies
Cohen-Adad, J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.04.009 · Cited by 50
“For more details on the association between tissue composition and T1 relaxation the reader is referred to (Does, 2018).”
Formalin tissue fixation biases myelin – sensitive MRI
Seifert, A. C., Umphlett, M., Hefti, M., Fowkes, M., & Xu, J. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27821 · Cited by 44
Lynn, J. D., Anand, C., Arshad, M., Homayouni, R., Rosenberg, D. R., Ofen, N., Raz, N., & Stanley, J. A. (2021) · Cerebral Cortex · doi:10.1093/cercor/bhaa272 · Cited by 33
“This spatial expansion is consistent with higher geomT 2IEW values that reflect increased water mobility (Carr and Purcell 1954; Meiboom and Gill 1958; MacKay et al. 1994; Whittall et al. 1997; Does 2018).”
BackgroundResultInfluentialAlsameen, M. H., Gong, Z., Qian, W., Kiely, M., Triebswetter, C., Bergeron, C. M., Cortina, L. E., Faulkner, M. E., Laporte, J. P., & Bouhrara, M. (2023) · Frontiers in Neurology · doi:10.3389/fneur.2023.1205426 · Cited by 29
Metadata
- Authors
- Does, M. D.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 182
- Pages
- 136-148
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2782273750
- Cited by
- 137
- References
- 15
- FWCI
- 9.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.