Implementing the centiloid transformation for 11C-PiB and β-amyloid 18F-PET tracers using CapAIBL
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
&NA; The centiloid scale was recently proposed to provide a standard framework for the quantification of &bgr;‐amyloid PET images, so that amyloid burden can be expressed on a standard scale. While the framework prescribes SPM8 as the standard analysis method for PET quantification, non‐standard methods can be calibrated to produce centiloid values. We have previously developed a PET‐only quantification: CapAIBL. In this study, we show how CapAIBL can be calibrated to the centiloid scale. Methods Calibration images for 11C‐PiB, 18F‐NAV4694, 18F‐Florbetaben, 18F‐Flutemetamol and 18F‐ Florbetapir were analysed using the standard method and CapAIBL. Using these images, both methods were calibrated to the centiloid scale. Centiloid values computed using CapAIBL were compared to those computed using standard method. For each tracer, a separate validation was performed using an independent dataset from the AIBL study. Results Using the calibration images, there was a very strong agreement, and very little bias between the centiloid values computed using CapAIBL and those computed using the standard method with R2 > 0.97 across all tracers. Using images from AIBL, the agreement was also high with R2 > 0.96 across all tracers. In this dataset, there was a small underestimation of the centiloid values computed using CapAIBL of less than 0.8% in PiB, and a small over‐estimation of 1.3% in Florbetapir, and 0.8% in Flutemetamol. There was a larger overestimation of 8% in NAV images, and 14% underestimation in Florbetaben images. However, some of these differences could be explained by the use of different scanners between the calibration scans and the ones used in AIBL. Conclusion The PET‐only quantification method, CapAIBL, can produce reliable centiloid values. The bias observed in the AIBL dataset for 18F‐NAV4694 and 18F‐Florbetaben may indicate that using different scanners or reconstruction methods might require scanner‐specific adjustments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Centiloid Project: standardizing quantitative amyloid plaque estimation by PET
Klunk, W. E., Koeppe, R. A., Price, J. C., Benzinger, T. L., Devous, M. D., Jagust, W. J., Johnson, K. A., Mathis, C. A., Minhas, D., Pontecorvo, M. J., et al. (2015) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2014.07.003 · Cited by 1,348
Self-citationImaging β-amyloid burden in aging and dementia
Rowe, C. C., Ng, S., Ackermann, U., Gong, S. J., Pike, K., Savage, G., Cowie, T. F., Dickinson, K. L., Maruff, P., Darby, D., et al. (2007) · Neurology · doi:10.1212/01.wnl.0000261919.22630.ea · Cited by 1,104 · cited 1×
“The variability is also exacerbated by the use of different tracers, each having different pharmacokinetics, binding potentials, recommended acquisition protocol and reference region (3,4,5,6).”
Self-citationClark, C. M., Pontecorvo, M. J., Beach, T. G., Bedell, B. J., Coleman, R. E., Doraiswamy, P. M., Fleisher, A. S., Reiman, E. M., Sabbagh, M. N., Sadowsky, C. H., et al. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(12)70142-4 · Cited by 855 · cited 1×
“The variability is also exacerbated by the use of different tracers, each having different pharmacokinetics, binding potentials, recommended acquisition protocol and reference region (3,4,5,6).”
Reducing between scanner differences in multi-center PET studies
Joshi, A., Koeppe, R. A., & Fessler, J. A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.057 · Cited by 247 · cited 2×
“M AN US CR IP T AC CE PT ED ACCEPTED MANUSCRIPT specific differences could also introduce biases when using the standard pipeline, as previous studies have shown inter-scanner image variability in multi-centre studies, requiring scanner specific calibrations (15,16).”
Cited by
Ashton, N. J., Janelidze, S., Mattsson-Carlgren, N., Binette, A. P., Strandberg, O., Brum, W. S., Karikari, T. K., González-Ortiz, F., Di Molfetta, G., Meda, F. J., et al. (2022) · Nature Medicine · doi:10.1038/s41591-022-02074-w · Cited by 436
Ossenkoppele, R., Smith, R., Mattsson-Carlgren, N., Groot, C., Leuzy, A., Strandberg, O., Palmqvist, S., Olsson, T., Jögi, J., Stormrud, E., et al. (2021) · JAMA Neurology · doi:10.1001/jamaneurol.2021.1858 · Cited by 311
Chatterjee, P., Pedrini, S., Doecke, J. D., Thota, R., Villemagne, V. L., Doré, V., Singh, A. K., Wang, P., Rainey‐Smith, S., Fowler, C., et al. (2023) · Alzheimer's & Dementia · doi:10.1002/alz.12724 · Cited by 312
Self-citationCSF MTBR-tau243 is a specific biomarker of tau tangle pathology in Alzheimer’s disease
Horie, K., Salvadó, G., Barthélemy, N. R., Janelidze, S., Li, Y., He, Y., Saef, B., Chen, C. D., Jiang, H., Strandberg, O., et al. (2023) · Nature Medicine · doi:10.1038/s41591-023-02443-z · Cited by 249
Quantification of amyloid PET for future clinical use: a state-of-the-art review
Pemberton, H. G., Collij, L. E., Heeman, F., Bollack, A., Shekari, M., Salvadó, G., Alves, I. L., Garcia, D. V., Battle, M., Buckley, C., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05784-y · Cited by 226
Metadata
- Authors
- Bourgeat, P., Doré, V., Fripp, J., Ames, D., Masters, C. L., Salvado, O., Villemagne, V. L., & Rowe, C. C.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 183
- Pages
- 387-393
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2888048543
- Cited by
- 157
- References
- 4
- FWCI
- 7.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.