CoChat

Passive exposure to speech sounds modifies change detection brain responses in adults

Open access

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index; none of the 53 sources its claims cite is checked for support yet.

Overview

CoChat Summary

TL;DR

Passive exposure of adult Finnish speakers to Chinese lexical tones for 2 h/day over 4 consecutive days (8 h total) modified cortical change-detection ERPs to speech sounds and transferred to sinusoidal sounds, without changing behavioral discrimination. The results suggest passive exposure in adulthood can enhance neural discrimination and attention orientation to foreign speech sounds.

Key findings

  • In the attend condition, passive exposure increased P3b amplitude to deviant speech sounds from 2.98 ± 1.55 µV pre to 3.61 ± 1.20 µV post, t(14) = 2.78, p = 0.032, d = 0.45; N2b amplitude/latency showed no session × group effects.
  • In the ignore condition for speech sounds, MMN latency shortened from 222.45 ± 19.61 ms pre to 194.57 ± 24.81 ms post, t(17) = 4.79, p = 0.00, d = 1.25; P3a amplitude to deviants became more positive from −0.30 ± 0.74 µV to 0.57 ± 0.57 µV, t(17) = 4.70, p = 0.002, d = 1.32; P3a latency for the large deviant shortened from 294.0 ± 24.5 ms to 273.6 ± 14.9 ms, t(17) = 2.92, p = 0.02, d = 1.00.
  • The exposure effect transferred to sinusoidal sounds: MMN latency shortened from 234.9 ± 10.58 ms pre to 215.27 ± 21.44 ms post in the exposure group, t(17) = 3.88, p = 0.014, d = 1.16, with no such change in controls; no transfer was found for P3a amplitude or latency.
  • Behavioral responses showed no session × group interactions; large deviants were detected more accurately (97.0%) than small deviants (88.4%), and reaction times decreased from pre to post in both groups, more for small deviants.

Methods

  • Thirty-nine monolingual Finnish-speaking adults (mean age 23.0 ± 3.3 years; 32 females, 7 males) were assigned to a passive exposure group (n = 18, mean age 21.7 ± 1.7 years) or a no-exposure control group (n = 21, mean age 24.1 ± 3.6 years). After EEG artifact rejection, ignore-condition data remained for 18 exposure and 18 control participants; attend-condition data remained for 15 exposure and 21 control participants.
  • Participants completed pre- and post-exposure EEG sessions on days 1 and 5. The exposure group passively listened to Chinese lexical tones in an oddball paradigm for 2 h/day on 4 consecutive days (8 h total) while watching silent movies; controls received no exposure. Stimuli included speech sounds (falling standard, small slightly falling deviant, large rising deviant) and sinusoidal sounds mimicking their pitch contours, presented in ignore and attend conditions.
  • EEG was recorded with 128-channel EGI nets at 500 Hz. ERPs were analyzed with repeated-measures ANOVAs including stimulus type, deviant type, electrode cluster, session, and group; behavioral data were analyzed with repeated-measures ANOVA on deviant type, session, and group. Significance was p < 0.05, with bootstrapping (1,000 permutations) and Cohen’s d reported.

Limitations

  • Stated: the authors note it is possible the passive exposure should have been more extended to induce behavioral changes; it remains unclear whether perceptual learning requires attentive training, and if so identification rather than discrimination training, to modulate N2b; the generalization effect was not observed for P3a amplitude or latency.
  • Evident from the text: the attend-condition exposure group was small (n = 15) and group sizes were unequal; no behavioral exposure effect was found; exposure-phase EEG data were recorded but not reported.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2018.12.010

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

4 tests recomputed · 0 with the reported and recomputed p on opposite sides of .05

Figures

Image 1
CC-BY-NC-ND · From the PDF
Image 2
CC-BY-NC-ND · From the PDF
ACCEPTED MANUSCRIPT Fig. 2. Grand averaged P3b responses in the exposure group, n =15 and the control group, n = 21. The gray lines represent responses to deviant sounds from the pre measurement, and the black lines signify the responses to deviant sounds from the post measurement. Grand averaged waveforms are presented as mean values from the collapsed electrode clusters (left, middle, and right parietal; see Supplementary Fig. 1 and 3). In lower panel, grand averaged scalp topographies of the deviant responses as a mean amplitude value of the analyzed time window at 360-410 ms from the 128 electrodes for the P3b for the exposure group and control group are shown. -1.5 -100 Pre
ACCEPTED MANUSCRIPT Fig. 2. Grand averaged P3b responses in the exposure group, n =15 and the control group, n = 21. The gray lines represent responses to deviant sounds from the pre measurement, and the black lines signify the responses to deviant sounds from the post measurement. Grand averaged waveforms are presented as mean values from the collapsed electrode clusters (left, middle, and right parietal; see Supplementary Fig. 1 and 3). In lower panel, grand averaged scalp topographies of the deviant responses as a mean amplitude value of the analyzed time window at 360-410 ms from the 128 electrodes for the P3b for the exposure group and control group are shown. -1.5 -100 PreCC-BY-NC-ND · From the PDF
Image 4
CC-BY-NC-ND · From the PDF
ACCEPTED MANUSCRIPT Fig. 4. Grand averaged deviant responses in the time windows of the mismatch negativity (MMN) and P3a responses in the exposure group, n = 18, and in the control group, n = 18. Grand average waveforms to deviant responses (small and large deviant averaged) are presented as mean values from the collapsed electrode clusters (left frontal, middle frontal, right frontal; see Material and methods and Supplementary Fig. 1 and 4). The gray lines represent responses in the pre measurement, while black lines represent responses in the post measurement for the exposure group and the control group. The light gray bars represent the time windows analyzed for the MMN and P3a responses (190-240 ms and 250-300 ms post stimulus onset, respectively). In lower panel, the grand averaged scalp topographies of the responses to deviant sounds as a mean amplitude value of the analyzed time window from the 128 electrodes for the MMN and P3a for the exposure group and the control group are shown. -2.0 Pre Post
ACCEPTED MANUSCRIPT Fig. 4. Grand averaged deviant responses in the time windows of the mismatch negativity (MMN) and P3a responses in the exposure group, n = 18, and in the control group, n = 18. Grand average waveforms to deviant responses (small and large deviant averaged) are presented as mean values from the collapsed electrode clusters (left frontal, middle frontal, right frontal; see Material and methods and Supplementary Fig. 1 and 4). The gray lines represent responses in the pre measurement, while black lines represent responses in the post measurement for the exposure group and the control group. The light gray bars represent the time windows analyzed for the MMN and P3a responses (190-240 ms and 250-300 ms post stimulus onset, respectively). In lower panel, the grand averaged scalp topographies of the responses to deviant sounds as a mean amplitude value of the analyzed time window from the 128 electrodes for the MMN and P3a for the exposure group and the control group are shown. -2.0 Pre PostCC-BY-NC-ND · From the PDF
ACCEPTED MANUSCRIPT Fig. 5. Mismatch negativity latency and P3a latency and amplitude are enhanced after the passive exposure. The white and gray bars represent the mean values from the pre and post measurements, respectively. Error bars indicate the standard error of the mean. *** indicates a statistically significant (p < .05) difference. The latency of the response to the deviant sounds in the MMN time window shortened from the pre measurement (222.45 ms ± 19.61)) to the post measurement (194.57 ms ± 24.81), t(17) = 4.79, p = 0.00, 95% CI [17.44, 39.78], d = 1.25), in the exposure group, while there were no changes in the control group. In addition, in the P3a time window, deviant response latencies became significantly shorter for the large deviant after the exposure, but not for the small deviant, and there were no changes in the control group. Standard response amplitudes were more positive after the exposure (-0.05 µV ± 0.64) compared to the pre measurement (-0.53 µV ± 0.55), t17 = 3.18, p = 0.026, 95% CI [-0.79, -0.19], d = 0.80. Also deviant response amplitudes became more positive after the exposure (0.57 µV ± 0.57) compared to the pre measurement (-0.30 µV ± 0.74), t(17) = 4.70, p = 0.002, 95% CI [-1.23, -0.53], d = 1.32. 320 Latency (ms) 220 0.8 Amplitude (μV) - 0.8 ***
ACCEPTED MANUSCRIPT Fig. 5. Mismatch negativity latency and P3a latency and amplitude are enhanced after the passive exposure. The white and gray bars represent the mean values from the pre and post measurements, respectively. Error bars indicate the standard error of the mean. *** indicates a statistically significant (p < .05) difference. The latency of the response to the deviant sounds in the MMN time window shortened from the pre measurement (222.45 ms ± 19.61)) to the post measurement (194.57 ms ± 24.81), t(17) = 4.79, p = 0.00, 95% CI [17.44, 39.78], d = 1.25), in the exposure group, while there were no changes in the control group. In addition, in the P3a time window, deviant response latencies became significantly shorter for the large deviant after the exposure, but not for the small deviant, and there were no changes in the control group. Standard response amplitudes were more positive after the exposure (-0.05 µV ± 0.64) compared to the pre measurement (-0.53 µV ± 0.55), t17 = 3.18, p = 0.026, 95% CI [-0.79, -0.19], d = 0.80. Also deviant response amplitudes became more positive after the exposure (0.57 µV ± 0.57) compared to the pre measurement (-0.30 µV ± 0.74), t(17) = 4.70, p = 0.002, 95% CI [-1.23, -0.53], d = 1.32. 320 Latency (ms) 220 0.8 Amplitude (μV) - 0.8 ***CC-BY-NC-ND · From the PDF
Image 7
CC-BY-NC-ND · From the PDF
Image 8
CC-BY-NC-ND · From the PDF
Image 9
CC-BY-NC-ND · From the PDF
Image 10
CC-BY-NC-ND · From the PDF
Fig. 6 Grand averaged MMN and P3a responses to sinusoidal sounds. Grand averaged waveforms of responses reflecting MMN and P3a in the exposure group (n = 18) and the control group (n = 18). The gray lines represent responses to deviant sounds (large and small deviant types averaged) from the pre measurement, while black lines represent responses to deviant sounds from the post measurement for the exposure group and the control group. The light gray bars represent the time windows applied in the analysis of for the P3a amplitude (mean amplitude value between 300-350 ms). The mean scalp topographies of the differential response (standard subtracted from the deviant, deviant types averaged) from the 128 electrodes for the P3a for the exposure group and the control group from the analyzed time window. Although there was a significant stimulus type x electrode cluster x session x group effect for the P3a amplitude, post-hoc tests did not reveal any generalization of the exposure effect. Please note that the MMN amplitude was not investigated since there was no exposure effect for it.
Fig. 6 Grand averaged MMN and P3a responses to sinusoidal sounds. Grand averaged waveforms of responses reflecting MMN and P3a in the exposure group (n = 18) and the control group (n = 18). The gray lines represent responses to deviant sounds (large and small deviant types averaged) from the pre measurement, while black lines represent responses to deviant sounds from the post measurement for the exposure group and the control group. The light gray bars represent the time windows applied in the analysis of for the P3a amplitude (mean amplitude value between 300-350 ms). The mean scalp topographies of the differential response (standard subtracted from the deviant, deviant types averaged) from the 128 electrodes for the P3a for the exposure group and the control group from the analyzed time window. Although there was a significant stimulus type x electrode cluster x session x group effect for the P3a amplitude, post-hoc tests did not reveal any generalization of the exposure effect. Please note that the MMN amplitude was not investigated since there was no exposure effect for it.CC-BY-NC-ND · From the PDF

Verification

Claims the paper makes

0 Valid · 0 Not valid · 28 Not checked · 65 Own results and interpretations

33 more claims

Create a free account to see all 93 claims and to verify the 51 references still open.

See all claims — free account
  • Probably not a substantial claim. 29
  • It may state two separate claims as one. 28
  • The quote only partly states this claim. 5

Create a free account to see these claims.

Statistics that don’t add up

Each reported p-value recomputed from its test statistic and degrees of freedom.

2 of 2

Statistics recomputed

Every reported test result, recomputed from its test statistic and degrees of freedom. A result shows as not adding up only once an independent check has confirmed it.

  • Doesn’t add upt(14) = 2.78reported p = .032 · recomputed p = .015

    “t(14) = 2.78, p = .032”

  • Doesn’t add upt(17) = 4.7reported p = .002 · recomputed p < .001

    “t(17) = 4.70, p = .002”

  • Consistentt(17) = 4.79reported p = 0 · recomputed p < .001

    “t(17) = 4.79, p = .00”

  • Consistentt(17) = 3.88reported p = .014 · recomputed p = .001

    “t(17) = 3.88, p = .014”

    The paper states a correction for multiple tests

4 of 4

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Self-check results appear here once an independent check has confirmed them.

Citations

Cites

Cited by

See all 23

Metadata

Authors
Kurkela, J. L. O., Hämäläinen, J. A., Leppänen, P. H. T., Shu, H., & Astikainen, P.
Affiliations
  • University of Jyväskylä (FI)
  • Beijing Normal University (CN)
Corresponding author
Kurkela, Jari L.O.
Venue
NeuroImage
Publisher
Elsevier BV
Published
2019-03
Volume
188
Pages
208-216
ISSN
1053-8119 (ISSN-L)
OpenAlex
W2904170553
Cited by
22
References
39
Citations by year
2026: 7 · 2025: 2 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 2 · 2020: 3 · 2019: 1
FWCI
0.65
Type
journal article
Language
en
Open access
Licence
  • cc-by-nc-nd
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • NeuroImage (publishedVersion)
  • PubMed (publishedVersion)
  • Jyväskylä University Digital Archive (University of Jyväskylä) (acceptedVersion, cc-by-nc-nd)
Funders
  • National Natural Science Foundation of China (81461130018)
  • Academy of Finland (273134)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Neuroscience and Music Perception
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Phonetics and Phonology Research
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Neurobiology of Language and Bilingualism
Keywords
auditory discrimination, change detection, mismatch negativity, P3a, P3b, speech sound processing, cross-modal transfer, event-related potentials, attentional orienting
MeSH terms
Acoustic Stimulation, Adult, Attention, Brain, Evoked Potentials, Auditory, Female, Humans, Male, Neuronal Plasticity, Speech, Speech Perception, Event-Related Potentials, P300, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-19, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-19 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.