In-vivo multi-exponential T2, magnetization transfer and quantitative histology in a rat model of intramyelinic edema
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Two MRI methods, multi-exponential analysis of transverse relaxation (MET2) and quantitative magnetization transfer (qMT), were used along with quantitative evaluation of histology in a study of intra-myelinic edema in rat spinal white matter. The results showed a strong linear correlation between a distinct long-T2 signal from MET2 analysis and the edema water volume fraction as measured by histology, although this analysis overestimated the edema water content by ≈ 100% relative to quantitative histological measurements. This overestimation was reasoned to result from the effects of inter-compartmental water exchange on observed transverse relaxation. Commonly studied MRI markers for myelin, the myelin water fraction (from MET2 analysis) and the macromolecular pool size ratio (from qMT analysis) produced results that could not be explained purely by changes in myelin content. The results demonstrate the potential for MET2 analysis as well as the limits of putative myelin markers for characterizing white matter abnormalities involving intra-myelinic edema.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology
Laule, C., Leung, E., Li, D. K., Traboulsee, A. L., Paty, D. W., MacKay, A. L., & Moore, G. R. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070928 · Cited by 489
A pathology–MRI study of the short-T2 component in formalin-fixed multiple sclerosis brain
Moore, G. R. W., Leung, E., MacKay, A. L., Vavasour, I. M., Whittall, K. P., Cover, K. S., Li, D. K. B., Hashimoto, S. A., Oger, J., Sprinkle, T. J., et al. (2000) · Neurology · doi:10.1212/wnl.55.10.1506 · Cited by 185
MR properties of excised neural tissue following experimentally induced inflammation
Stanisz, G. J., Webb, S., Munro, C. A., Pun, T., & Midha, R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20008 · Cited by 138 · cited 5×
“For example, inflammation in the absence of myelin served. loss shifts the long-T2 components to greater T2 values (Stanisz et al., 2004), and an additional long T2 signal (>100 ms) has been observed in the white matter of patients with phenylketonuria (Laule et al., 2007; Sirrs et al., 2007) and…”
BackgroundInfluential
Cited by
Kamiya, K., Hori, M., & Aoki, S. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108908 · Cited by 321
An interactive meta-analysis of MRI biomarkers of myelin
Mancini, M., Karakuzu, A., Cohen-Adad, J., Cercignani, M., Nichols, T. E., & Stikov, N. (2020) · eLife · doi:10.7554/elife.61523 · Cited by 168
So You Want to Image Myelin Using MRI: An Overview and Practical Guide for Myelin Water Imaging
Lee, J., Hyun, J., Lee, J., Choi, E., Shin, H., Min, K., Nam, Y., Kim, H. J., & Oh, S. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27059 · Cited by 134
“We encourage you to read a few articles that discuss the different aspects of MWI.1–5 Question 1: Tell Me About Myelin ANSWER 1.”
BackgroundInfluentialBilliet, T., Mädler, B., D'Arco, F., Peeters, R., Deprez, S., Plasschaert, E., Leemans, A., Zhang, H., den Bergh, B. V., Vandenbulcke, M., et al. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.04.005 · Cited by 101
Formalin tissue fixation biases myelin – sensitive MRI
Seifert, A. C., Umphlett, M., Hefti, M., Fowkes, M., & Xu, J. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27821 · Cited by 44
Metadata
- Authors
- Harkins, K. D., Valentine, W. M., Gochberg, D. F., & Does, M. D.
- Venue
- NeuroImage: Clinical
- Publisher
- Elsevier BV
- Published
- 2013
- Volume
- 2
- Pages
- 810-817
- ISSN
- 2213-1582 (ISSN-L)
- OpenAlex
- W2146649392
- Cited by
- 25
- References
- 3
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.