A pathology–MRI study of the short-T2 component in formalin-fixed multiple sclerosis brain
Abstract
Objective To determine the pathologic basis of areas not exhibiting signal of the short-T2 component of the T2 relaxation distribution in MS, as studied in formalin-fixed brain. Background A myelin-specific MRI signal would be of great importance in assessing demyelination in patients with MS. Evidence indicates that the short-T2 (10 to 50 millisecond) component of the T2 relaxation distribution originates from water in myelin sheaths. The authors present two cases of MS in which the anatomic distribution of the short-T2 component was correlated with the pathologic findings in postmortem formalin-fixed brain. Method One half of the formalin-fixed brain was suspended in a gelatin-albumin mixture cross-linked with glutaraldehyde, and scanned with a 32-echo MRI sequence. The brain was then cut along the center of the 5-mm slices scanned, photographed, dehydrated, and embedded in paraffin. Paraffin sections, stained with Luxol fast blue and immunocytochemically for 2',3'-cyclic nucleotide 3'-phosphohydrolase for myelin and by the Bielschowsky technique for axons, were compared with the distribution of the amplitude of the short-T2 component of the comparable image slices. Results The anatomic distribution of the short-T2 component signal corresponded to the myelin distribution. Chronic, silent MS plaques with myelin loss correlated with areas of absence of short-T2 signal. The numbers of axons within lesions were reduced, but many surviving axons were also seen in these areas of…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Post mortem experiments have provided insights into the pathological correlates of several MR indices including T1 hypo-intensity, T1- and T2-RT and MT ratio.
“Such experiments have so far provided insights into the pathological correlates of several MR indices including T1 hypo-intensity (van Walderveen et al., 1998; van Waesberghe et al., 1999; Barkhof et al., 2003), T1- (Schmierer et al., 2004a) and T2-RT (Moore et al., 2000) and MT ratio (van Waesberghe et al., 1999; Barkhof et al., 2003; Schmierer et al., 2004a).”
From Diffusion tensor imaging of post mortem multiple sclerosis brain (2007) · cites this paper as Moore et al., 2000
Cites
Axonal transection in the lesions of multiple sclerosis
Trapp, B. D., Peterson, J., Ransohoff, R. M., Rudick, R., Mörk, S., & Bö, L. (1998) · New England Journal of Medicine · doi:10.1056/nejm199801293380502 · Cited by 4,029 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
MRI in multiple sclerosis: current status and future prospects
Bakshi, R., Thompson, A. J., Rocca, M. A., Pelletier, D., Dousset, V., Barkhof, F., Inglese, M., Guttmann, C. R., Horsfield, M. A., & Filippi, M. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70137-6 · Cited by 348 · see citing works
Diffusion tensor imaging of post mortem multiple sclerosis brain
Schmierer, K., Wheeler-Kingshott, C. A. M., Boulby, P. A., Scaravilli, F., Altmann, D. R., Barker, G. J., Tofts, P. S., & Miller, D. H. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.12.010 · Cited by 395 · see citing works
Magnetic Resonance Imaging of Myelin
Laule, C., Vavasour, I. M., Kolind, S. H., Li, D. K. B., Traboulsee, T. L., Moore, G. R. W., & MacKay, A. L. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.004 · Cited by 334 · see citing works
Self-citationIs diffusion anisotropy an accurate monitor of myelination?
Mädler, B., Drabycz, S. A., Kolind, S. H., Whittall, K. P., & MacKay, A. L. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.047 · Cited by 227 · see citing works
Self-citationDawe, R. J., Bennett, D. A., Schneider, J. A., Vasireddi, S. K., & Arfanakis, K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21909 · Cited by 162 · see citing works
Kolind, S. H., Laule, C., Vavasour, I. M., Li, D. K. B., Traboulsee, A. L., Mädler, B., Moore, G. R. W., & MacKay, A. L. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.033 · Cited by 44 · see citing works
Self-citation
- Authors
- Moore, G. R. W., Leung, E., MacKay, A. L., Vavasour, I. M., Whittall, K. P., Cover, K. S., Li, D. K. B., Hashimoto, S. A., Oger, J., Sprinkle, T. J., & Paty, D. W.
- Affiliations
- University of British Columbia (CA)
- Venue
- Neurology
- Published
- 2000-11-28
- Volume
- 55
- Issue
- 10
- Pages
- 1506-1510
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2050886347
- Cited by
- 185
- References
- 1
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 7 · 2023: 3 · 2022: 6 · 2021: 9 · 2020: 8 · 2019: 6 · 2018: 10 · 2017: 10 · 2016: 5 · 2015: 5 · 2014: 7 · 2013: 6 · 2012: 7
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Neurology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pathology and Forensic Medicine › Multiple Sclerosis Research Studies
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Keywords
- multiple sclerosis, myelin water, demyelination, axons, postmortem neuropathology
- MeSH terms
- Aged, Brain, Female, Humans, Magnetic Resonance Imaging, Middle Aged, Multiple Sclerosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review