Automatic segmentation and volumetry of multiple sclerosis brain lesions from MR images
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The location and extent of white matter lesions on magnetic resonance imaging (MRI) are important criteria for diagnosis, follow-up and prognosis of multiple sclerosis (MS). Clinical trials have shown that quantitative values, such as lesion volumes, are meaningful in MS prognosis. Manual lesion delineation for the segmentation of lesions is, however, time-consuming and suffers from observer variability. In this paper, we propose MSmetrix, an accurate and reliable automatic method for lesion segmentation based on MRI, independent of scanner or acquisition protocol and without requiring any training data. In MSmetrix, 3D T1-weighted and FLAIR MR images are used in a probabilistic model to detect white matter (WM) lesions as an outlier to normal brain while segmenting the brain tissue into grey matter, WM and cerebrospinal fluid. The actual lesion segmentation is performed based on prior knowledge about the location (within WM) and the appearance (hyperintense on FLAIR) of lesions. The accuracy of MSmetrix is evaluated by comparing its output with expert reference segmentations of 20 MRI datasets of MS patients. Spatial overlap (Dice) between the MSmetrix and the expert lesion segmentation is 0.67 ± 0.11. The intraclass correlation coefficient (ICC) equals 0.8 indicating a good volumetric agreement between the MSmetrix and expert labelling. The reproducibility of MSmetrix' lesion volumes is evaluated based on 10 MS patients, scanned twice with a short interval on three different scanners. The agreement between the first and the second scan on each scanner is evaluated through the spatial overlap and absolute lesion volume difference between them. The spatial overlap was 0.69 ± 0.14 and absolute total lesion volume difference between the two scans was 0.54 ± 0.58 ml. Finally, the accuracy and reproducibility of MSmetrix compare favourably with other publicly available MS lesion segmentation algorithms, applied on the same data using default parameter settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874 · cited 1×
“Spatial agreement is reported by the Dice similarity index (Dice, 1945), defined as the ratio between the number of voxels where both the automatic and the expert reference segmentation agree (true positives) and the mean number of voxels labelled as lesion by the two methods.”
MethodDiagnostic criteria for multiple sclerosis: 2010 revisions to the McDonald criteria
Polman, C. H., Reingold, S. C., Banwell, B., Clanet, M., Cohen, J. A., Filippi, M., Fujihara, K., Havrdova, E., Hutchinson, M., Kappos, L., et al. (2011) · Annals of Neurology · doi:10.1002/ana.22366 · Cited by 9,802 · cited 1×
“Brain MRI scans are part of the clinical routine of MS patients for both diagnosis and follow-up (Polman et al., 2011).”
Compston, A., & Coles, A. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61620-7 · Cited by 4,372
New Multiple Sclerosis Phenotypic Classification
Lublin, F. D. (2014) · European Neurology · doi:10.1159/000367614 · Cited by 4,259
Encyclopedia of Statistical Sciences.
Aspinall, L. J., Kotz, S., & Johnson, N. L. (1983) · Applied Statistics · doi:10.2307/2347959 · Cited by 1,258
An automated tool for detection of FLAIR-hyperintense white-matter lesions in Multiple Sclerosis
Schmidt, P., Gaser, C., Arsic, M., Buck, D., Förschler, A., Berthele, A., Hoshi, M., Ilg, R., Schmid, V. J., Zimmer, C., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.032 · Cited by 1,223 · cited 4×
“In addition, results are compared both quantitatively and qualitatively with two well-known and publicly available automatic unsupervised lesion segmentation software implementations: LST (Schmidt et al., 2012) and Lesion-TOADS (Shiee et al., 2010).”
MethodInfluentialFast free-form deformation using graphics processing units
Modat, M., Ridgway, G. R., Taylor, Z. A., Lehmann, M., Barnes, J., Hawkes, D. J., Fox, N. C., & Ourselin, S. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.09.002 · Cited by 1,085 · cited 1×
“The non-rigid registration is based on the Free-Form B-spline deformation model and also uses a multi-resolution approach (NiftyReg, Modat et al., 2010).”
MethodAutomated model-based tissue classification of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811270 · Cited by 1,024 · cited 2×
“This model is optimised using an expectation maximisation (EM) algorithm (Van Leemput et al., 1999) as implemented in NiftySeg (Cardoso, 2012).”
BackgroundMethodSelf-citationAutomated segmentation of multiple sclerosis lesions by model outlier detection
Van Leemput, K., Maes, F., Vandermeulen, D., Colchester, A., & Suetens, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.938237 · Cited by 489 · cited 2×
“This is performed using the same EM algorithm as described in the second step, but now an outlier map is included (Van Leemput et al., 2001).”
MethodResultSelf-citationGarcía-Lorenzo, D., Francis, S., Narayanan, S., Arnold, D. L., & Collins, D. L. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.09.004 · Cited by 355 · cited 2×
“…been segmented by 2 experts for the MICCAI (2008) challenge (http://www.ia.unc.edu/MSseg/) and variability reached a relative volume difference of 68% and a percentage of false negatives (number of lesions marked by one rater only) of 32%, as reported by García-Lorenzo et al. (2013); section 5.3.”
BackgroundInfluential
Cited by
Longitudinal multiple sclerosis lesion segmentation: Resource and challenge
Carass, A., Roy, S., Jog, A., Cuzzocreo, J. L., Magrath, E., Gherman, A., Button, J., Nguyen, J., Prados, F., Sudre, C. H., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.064 · Cited by 357
Self-citationon behalf of the MAGNIMS study group, Sastre-Garriga, J., Pareto, D., Battaglini, M., Rocca, M. A., Ciccarelli, O., Enzinger, C., Wuerfel, J., Sormani, M. P., Barkhof, F., et al. (2020) · Nature Reviews Neurology · doi:10.1038/s41582-020-0314-x · Cited by 273
Self-citationGhafoorian, M., Karssemeijer, N., Heskes, T., van Uden, I. W. M., Sanchez, C. I., Litjens, G., de Leeuw, F.-E., van Ginneken, B., Marchiori, E., & Platel, B. (2017) · Scientific Reports · doi:10.1038/s41598-017-05300-5 · Cited by 236
Multi-branch convolutional neural network for multiple sclerosis lesion segmentation
Aslani, S., Dayan, M., Storelli, L., Filippi, M., Murino, V., Rocca, M. A., & Sona, D. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.068 · Cited by 186
Evaluating White Matter Lesion Segmentations with Refined Sørensen-Dice Analysis
Carass, A., Roy, S., Gherman, A., Reinhold, J. C., Jesson, A., Arbel, T., Maier, O., Handels, H., Ghafoorian, M., Platel, B., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-64803-w · Cited by 185
De Winter, F.-L., Emsell, L., Bouckaert, F., Claes, L., Jain, S., Farrar, G., Billiet, T., Evers, S., Van den Stock, J., Sienaert, P., et al. (2017) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2016.16030319 · Cited by 80
Self-citation
Metadata
- Authors
- Jain, S., Sima, D. M., Ribbens, A., Cambron, M., Maertens, A., Van Hecke, W., De Mey, J., Barkhof, F., Steenwijk, M. D., Daams, M., Maes, F., Van Huffel, S., Vrenken, H., & Smeets, D.
- Venue
- NeuroImage: Clinical
- Publisher
- Elsevier BV
- Published
- 2015
- Volume
- 8
- Pages
- 367-375
- ISSN
- 2213-1582 (ISSN-L)
- OpenAlex
- W266124145
- Cited by
- 220
- References
- 19
- FWCI
- 20.80
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.