The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Translating state-of-the-art spinal cord MRI techniques to clinical use: A systematic review of clinical studies utilizing DTI, MT, MWF, MRS, and fMRI
Open accessAbstract
BACKGROUND: A recent meeting of international imaging experts sponsored by the International Spinal Research Trust (ISRT) and the Wings for Life Foundation identified 5 state-of-the-art MRI techniques with potential to transform the field of spinal cord imaging by elucidating elements of the microstructure and function: diffusion tensor imaging (DTI), magnetization transfer (MT), myelin water fraction (MWF), MR spectroscopy (MRS), and functional MRI (fMRI). However, the progress toward clinical translation of these techniques has not been established. METHODS: A systematic review of the English literature was conducted using MEDLINE, MEDLINE-in-Progress, Embase, and Cochrane databases to identify all human studies that investigated utility, in terms of diagnosis, correlation with disability, and prediction of outcomes, of these promising techniques in pathologies affecting the spinal cord. Data regarding study design, subject characteristics, MRI methods, clinical measures of impairment, and analysis techniques were extracted and tabulated to identify trends and commonalities. The studies were assessed for risk of bias, and the overall quality of evidence was assessed for each specific finding using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework. RESULTS: A total of 6597 unique citations were identified in the database search, and after full-text review of 274 articles, a total of 104 relevant studies were identified for final inclusion (97% from the initial database search). Among these, 69 studies utilized DTI and 25 used MT, with both techniques showing an increased number of publications in recent years. The review also identified 1 MWF study, 11 MRS studies, and 8 fMRI studies. Most of the studies were exploratory in nature, lacking a priori hypotheses and showing a high (72%) or moderately high (20%) risk of bias, due to issues with study design, acquisition techniques, and analysis methods. The acquisitions for each technique varied widely across studies, rendering direct comparisons of metrics invalid. The DTI metric fractional anisotropy (FA) had the strongest evidence of utility, with moderate quality evidence for its use as a biomarker showing correlation with disability in several clinical pathologies, and a low level of evidence that it identifies tissue injury (in terms of group differences) compared with healthy controls. However, insufficient evidence exists to determine its utility as a sensitive and specific diagnostic test or as a tool to predict clinical outcomes. Very low quality evidence suggests that other metrics also show group differences compared with controls, including DTI metrics mean diffusivity (MD) and radial diffusivity (RD), the diffusional kurtosis imaging (DKI) metric mean kurtosis (MK), MT metrics MT ratio (MTR) and MT cerebrospinal fluid ratio (MTCSF), and the MRS metric of N-acetylaspartate (NAA) concentration, although these results were somewhat inconsistent. CONCLUSIONS: State-of-the-art spinal cord MRI techniques are emerging with great potential to improve the diagnosis and management of various spinal pathologies, but the current body of evidence has only showed limited clinical utility to date. Among these imaging tools DTI is the most mature, but further work is necessary to standardize and validate its use before it will be adopted in the clinical realm. Large, well-designed studies with a priori hypotheses, standardized acquisition methods, detailed clinical data collection, and robust automated analysis techniques are needed to fully demonstrate the potential of these rapidly evolving techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gotzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · BMJ · doi:10.1136/bmj.b2700 · Cited by 17,648
Grading quality of evidence and strength of recommendations for diagnostic tests and strategies
Schünemann, H. J., Oxman, A. D., Brozek, J., Glasziou, P., Jaeschke, R., Vist, G. E., Williams, J. W., Kunz, R., Craig, J., Montori, V. M., et al. (2008) · BMJ · doi:10.1136/bmj.39500.677199.ae · Cited by 1,782
Jones, J. G. A., Cen, S. Y., Lebel, R. M., Hsieh, P. C., & Law, M. (2013) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3199 · Cited by 157 · cited 12×
“…results in 5/5 studies correlating with JOA or mJOA (Spearman r = 0.48–0.88, Pearson R = 0.57–0.64) (Ellingson et al., 2014; Gao et al., 2013; Jones et al., 2013; Maki et al., 2015; Wen et al., 2014b) and in SCI in 4/4 studies correlating with ASIA motor/ sensory scores (r = 0.59–0.74, R =…”
BackgroundMethodResultInfluentialMagnetization transfer MRI demonstrates spinal cord abnormalities in adrenomyeloneuropathy
Fatemi, A., Smith, S. A., Dubey, P., Zackowski, K. M., Bastian, A. J., van Zijl, P. C., Moser, H. W., Raymond, G. V., & Golay, X. (2005) · Neurology · doi:10.1212/01.wnl.0000164458.02141.06 · Cited by 64
Myelin Water Fraction in Human Cervical Spinal Cord In Vivo
Wu, Y., Alexander, A. L., Fleming, J. O., Duncan, I. D., & Field, A. S. (2006) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200603000-00026 · Cited by 51
Cited by
Traumatic Spinal Cord Injury—Repair and Regeneration
Ahuja, C. S., Nori, S., Tetreault, L., Wilson, J., Kwon, B., Harrop, J., Choi, D., & Fehlings, M. G. (2017) · Neurosurgery · doi:10.1093/neuros/nyw080 · Cited by 923
Self-citationSCT: Spinal Cord Toolbox, an open-source software for processing spinal cord MRI data
De Leener, B., Lévy, S., Dupont, S. M., Fonov, V. S., Stikov, N., Louis Collins, D., Callot, V., & Cohen-Adad, J. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.10.009 · Cited by 621
Self-citationDegenerative cervical myelopathy — update and future directions
Badhiwala, J. H., Ahuja, C. S., Akbar, M. A., Witiw, C. D., Nassiri, F., Furlan, J. C., Curt, A., Wilson, J. R., & Fehlings, M. G. (2020) · Nature Reviews Neurology · doi:10.1038/s41582-019-0303-0 · Cited by 540
Self-citationNouri, A., Martin, A. R., Mikulis, D., & Fehlings, M. G. (2016) · Neurosurgical Focus · doi:10.3171/2016.3.focus1667 · Cited by 218
Self-citationA systematic review of structural and functional MRI studies on pain catastrophizing
Galambos, A., Szabó, E., Nagy, Z., Édes, A. E., Kocsel, N., Juhász, G., & Kökönyei, G. (2019) · Journal of Pain Research · doi:10.2147/jpr.s192246 · Cited by 99
Metadata
- Authors
- Martin, A. R., Aleksanderek, I., Cohen-Adad, J., Tarmohamed, Z., Tetreault, L., Smith, N., Cadotte, D. W., Crawley, A., Ginsberg, H., Mikulis, D. J., & Fehlings, M. G.
- Venue
- NeuroImage: Clinical
- Publisher
- Elsevier BV
- Published
- 2016
- Volume
- 10
- Pages
- 192-238
- ISSN
- 2213-1582 (ISSN-L)
- OpenAlex
- W2182563485
- Cited by
- 233
- References
- 5
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.