CoChat

MRI FLAIR lesion segmentation in multiple sclerosis: Does automated segmentation hold up with manual annotation?

Open access
Egger, Christine, Opfer, Roland, Wang, Chenyu, Kepp, Timo, Sormani, Maria Pia, Spies, Lothar, Barnett, Michael, Schippling, Sven · 2017 · NeuroImage: Clinical
Cited by 116

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

INTRODUCTION: Magnetic resonance imaging (MRI) has become key in the diagnosis and disease monitoring of patients with multiple sclerosis (MS). Both, T2 lesion load and Gadolinium (Gd) enhancing T1 lesions represent important endpoints in MS clinical trials by serving as a surrogate of clinical disease activity. T2- and fluid-attenuated inversion recovery (FLAIR) lesion quantification - largely due to methodological constraints - is still being performed manually or in a semi-automated fashion, although strong efforts have been made to allow automated quantitative lesion segmentation. In 2012, Schmidt and co-workers published an algorithm to be applied on FLAIR sequences. The aim of this study was to apply the Schmidt algorithm on an independent data set and compare automated segmentation to inter-rater variability of three independent, experienced raters. METHODS: MRI data of 50 patients with RRMS were randomly selected from a larger pool of MS patients attending the MS Clinic at the Brain and Mind Centre, University of Sydney, Australia. MRIs were acquired on a 3.0T GE scanner (Discovery MR750, GE Medical Systems, Milwaukee, WI) using an 8 channel head coil. We determined T2-lesion load (total lesion volume and total lesion number) using three versions of an automated segmentation algorithm (Lesion growth algorithm (LGA) based on SPM8 or SPM12 and lesion prediction algorithm (LPA) based on SPM12) as first described by Schmidt et al. (2012). Additionally, manual segmentation was performed by three independent raters. We calculated inter-rater correlation coefficients (ICC) and dice coefficients (DC) for all possible pairwise comparisons. RESULTS: We found a strong correlation between manual and automated lesion segmentation based on LGA SPM8, regarding lesion volume (ICC = 0.958 and DC = 0.60) that was not statistically different from the inter-rater correlation (ICC = 0.97 and DC = 0.66). Correlation between the two other algorithms (LGA SPM12 and LPA SPM12) and manual raters was weaker but still adequate (ICC = 0.927 and DC = 0.53 for LGA SPM12 and ICC = 0.949 and DC = 0.57 for LPA SPM12). Variability of both manual and automated segmentation was significantly higher regarding lesion numbers. CONCLUSION: Automated lesion volume quantification can be applied reliably on FLAIR data sets using the SPM based algorithm of Schmidt et al. and shows good agreement with manual segmentation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nicl.2016.11.020

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 116

Metadata

Authors
Egger, C., Opfer, R., Wang, C., Kepp, T., Sormani, M. P., Spies, L., Barnett, M., & Schippling, S.
Venue
NeuroImage: Clinical
Publisher
Elsevier BV
Published
2017
Volume
13
Pages
264-270
ISSN
2213-1582 (ISSN-L)
OpenAlex
W2549949175
Cited by
116
References
2
FWCI
6.16
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.