Cited by 4Gas Sensing Nanomaterials and SensorsAdvancements in Solid Oxide Fuel CellsAnalytical Chemistry and Sensors

A novel solution for hydrogen monitoring in fusion processes: 3D printed BaCe0.6Zr0.3Y0.1O3-α sensors

Open access
Hinojo, Antonio, Lujan, Enric, Abella, Jordi, Colominas, Sergi·2024·Nuclear Materials and Energy

Abstract

The control of tritium (3H) in liquid-based tritium breeding blankets (TBBs) is one of the key points to assure their correct performance to prove the 3H sufficiency. For that, electrochemical sensors are a good option for tritium quantification since they can perform in-situ and online measurements. One of the multiple challenges for hydrogen detection is to find suitable materials that can operate at high temperatures and in harsh environments. In this context, perovskite-type ceramics, such as BaCe0.6Zr0.3Y0.1O3-α (BCZY), have elevated proton conductivity and exceptional stability even in reducing atmospheres and at elevated temperatures, which make them strong contenders for high-temperature hydrogen sensing applications. In the present study, we describe the development of a dual-mode hydrogen sensors based on 3D-printed BCZY, which allows a high degree of design flexibility. Crucible geometries were tested and characterized using X-ray diffraction and scanning electron microscopy. Electrochemical sensors were constructed and characterized at 400, 450 and 500 °C in both, amperometric and potentiometric configuration. The results demonstrated the capability of 3D-printed BCZY sensors for hydrogen detection in fusion reactors, offering a breakthrough solution for monitoring fusion processes.

Integrity signals

Registry

Crossref · 10.1016/j.nme.2024.101661

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In perovskite-based electrochemical sensors, the working electrode is usually composed of perovskite materials or their composites.

    “As presented in Figure 3B, in perovskite-based electrochemical sensors, the working electrode is usually composed of perovskite materials or their composites [66].”
  • Perovskite-based electrochemical sensors can be classified into potentiometric, amperometric, and conductometric electrochemical sensors based on their working principles and application scenarios.

    “Based on their working principles and application scenarios, perovskite-based electrochemical sensors can be classified into potentiometric, amperometric, and conductometric electrochemical sensors (Figure 3) [11,66,[68][69][70][71].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Hinojo, A., Lujan, E., Abella, J., & Colominas, S.
Affiliations
Institut Químic de Sarrià (ES)
Corresponding author
Colominas, Sergi
Venue
Nuclear Materials and Energy
Publisher
Elsevier BV
Published
2024-06
Volume
39
Pages
101661
ISSN
2352-1791 (ISSN-L)
OpenAlex
W4395085583
Cited by
4
References
24
Citations by year
2025: 4
FWCI
0.41
Type
journal article
Language
en
Open access
Locations
  • Nuclear Materials and Energy (publishedVersion, cc-by-nc)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Gobierno de Espana Agencia Estatal de Investigacion (PID2022-140347OB-I00)
  • Generalitat de Catalunya (2021 FISDU 00136)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Materials Science › Materials Chemistry › Advancements in Solid Oxide Fuel Cells
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
hydrogen detection, tritium monitoring, tritium breeding blanket, perovskite oxides, proton conductivity, 3D-printed sensors, electrochemical sensor, amperometric sensor, potentiometric sensors, high-temperature sensors, fusion reactor, dual-mode sensor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review