CoChat

High-resolution imaging of brain 5-HT1B receptors in the rhesus monkey using [11C]P943

Open access
Nabulsi, Nabeel, Huang, Yiyun, Weinzimmer, David, Ropchan, Jim, Frost, James J., McCarthy, Timothy, Carson, Richard E., Ding, Yu-Shin · 2010 · Nuclear Medicine and Biology
Cited by 42

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The serotonin 5-HT1B receptors regulate the release of serotonin and are involved in various disease states, including depression and schizophrenia. The goal of the study was to evaluate a high affinity and high selectivity antagonist, [11C]P943, as a PET tracer for imaging the 5-HT1B receptor. [11C]P943 was synthesized via N-methylation of the precursor with [11C]methyl iodide or [11C]methyl triflate using automated modules. The average radiochemical yield was approx. 10% with radiochemical purity of >99% and specific activity of 8.8 ± 3.6 mCi/nmol at the end-of-synthesis (n = 37). PET imaging was performed in non-human primates with a High Resolution Research Tomograph (HRRT) scanner with a bolus/infusion paradigm. Binding potential (BPND) was calculated using the equilibrium ratios of regions to cerebellum. The tracer uptake was highest in the globus pallidus and occipital cortex, moderate in basal ganglia and thalamus, and lowest in the cerebellum, which is consistent with the known brain distribution of 5-HT1B receptors. Infusion of tracer at different specific activities (by adding various amount of unlabeled P943) reduced BPND values in a dose-dependent manner, demonstrating the saturability of the tracer binding. Blocking studies with GR127935 (2 mg/kg, IV), a selective 5-HT1B/5-HT1D antagonist, resulted in reduction of BPND values by 42-95% across regions; for an example, in occipital region from 0.71 to 0.03, indicating a complete blockade. These results demonstrate the saturability and specificity of [11C]P943 for 5HT1B receptors, suggesting its suitability as a PET radiotracer for in vivo evaluations of the 5-HT1B receptor system in humans.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nucmedbio.2009.10.007

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 42

Metadata

Authors
Nabulsi, N., Huang, Y., Weinzimmer, D., Ropchan, J., Frost, J. J., McCarthy, T., Carson, R. E., & Ding, Y.-S.
Venue
Nuclear Medicine and Biology
Publisher
Elsevier BV
Published
2010-02
Volume
37
Issue
2
Pages
205-214
ISSN
0969-8051 (ISSN-L)
OpenAlex
W2078168341
Cited by
42
References
4
FWCI
4.46
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-resolution imaging of brain 5-HT1B receptors in the rhesus monkey using [11C]P943. https://app.cochat.ai/papers/10.1016/j.nucmedbio.2009.10.007
The paper
Nabulsi, N., Huang, Y., Weinzimmer, D., Ropchan, J., Frost, J. J., McCarthy, T., Carson, R. E., & Ding, Y.-S. (2010). High-resolution imaging of brain 5-HT1B receptors in the rhesus monkey using [11C]P943. Nuclear Medicine and Biology. https://doi.org/10.1016/j.nucmedbio.2009.10.007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.