Insights into Advanced Retinopathy of Prematurity Using Handheld Spectral Domain Optical Coherence Tomography Imaging
Open accessAbstract
Purpose To elucidate the subclinical anatomy of retinopathy of prematurity (ROP) using spectral domain optical coherence tomography (SD OCT). Design Prospective, observational case series. Participants Three low-birth-weight, severely premature infants. Methods Clinical examination was performed using a portable slit lamp and indirect ophthalmoscope. Imaging was performed by using a handheld SD OCT device and Retcam (Clarity Medical Systems, Pleasanton, CA) or video-indirect recording. Spectral domain optical coherence tomography imaging was conducted without sedation at the bedside in the neonatal intensive care unit on 1 patient. The other 2 patients had an examination under anesthesia with SD OCT imaging in the operating room. Main Outcome Measures In vivo determination of vitreoretinal morphology, anatomy, and pathology by clinical examination, imaging, and SD OCT. Results Linear and volumetric imaging was achieved with the handheld system in infant eyes despite tunica vasculosa lentis and vitreous bands. Imaging was not possible in eyes with notable vitreous hemorrhage. Analysis of SD OCT images revealed preretinal structures (ranging from 409 to 2700 μm in width and 212 to 440 μm in height), retinoschisis, and retinal detachment in the posterior pole of patients with advanced ROP. Both the retinoschisis and the preretinal structures were not identified on conventional examination or imaging by expert pediatric ophthalmologists. The preretinal structures varied in location and size, and may represent preretinal fibrovascular proliferation. Some were found in close proximity to blood vessels, whereas others were near the optic nerve. Conclusions Handheld SD OCT imaging can be performed on the sedated or nonsedated neonate and provides valuable subclinical anatomic information. This novel imaging modality can reveal the location and extent of posterior ROP pathology not evident on standard examination. This could affect future clinical decision-making if studies validate a management strategy based on findings from this imaging technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Higashiyama, T., Muraki, S., & Ohji, M. (2017) · Case Reports in Ophthalmology · doi:10.1159/000461575 · Cited by 448
Intraoperative optical coherence tomography: past, present, and future
Ehlers, J. P. (2016) · Eye · doi:10.1038/eye.2015.255 · Cited by 77
Metadata
- Authors
- Chavala, S. H., Farsiu, S., Maldonado, R., Wallace, D. K., Freedman, S. F., & Toth, C. A.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2009-12
- Volume
- 116
- Issue
- 12
- Pages
- 2448-2456
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W1996347214
- Cited by
- 172
- References
- 0
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Insights into Advanced Retinopathy of Prematurity Using Handheld Spectral Domain Optical Coherence Tomography Imaging. https://app.cochat.ai/papers/10.1016/j.ophtha.2009.06.003
- The paper
- Chavala, S. H., Farsiu, S., Maldonado, R., Wallace, D. K., Freedman, S. F., & Toth, C. A. (2009). Insights into Advanced Retinopathy of Prematurity Using Handheld Spectral Domain Optical Coherence Tomography Imaging. Ophthalmology. https://doi.org/10.1016/j.ophtha.2009.06.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.