The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Enhanced Detection of Open-angle Glaucoma with an Anatomically Accurate Optical Coherence Tomography–Derived Neuroretinal Rim Parameter
Open accessAbstract
Objective Neuroretinal rim assessment based on the clinical optic disc margin (DM) lacks a sound anatomic basis for 2 reasons: (1) The DM is not reliable as the outer border of rim tissue because of clinically and photographically invisible extensions of Bruch’s membrane (BM) inside the DM and (2) nonaccountability of rim tissue orientation in the optic nerve head (ONH). The BM opening-minimum rim width (BMO-MRW) is a parameter that quantifies the rim from its true anatomic outer border, BMO, and accounts for its variable orientation. We report the diagnostic capability of BMO-MRW. Design Case control. Participants Patients with open-angle glaucoma (n = 107) and healthy controls (n = 48). Methods Spectral-domain optical coherence tomography (SD-OCT) with 24 radial and 1 circumpapillary B-scans, centered on the ONH, and confocal scanning laser tomography (CSLT) were performed. The internal limiting membrane (ILM) and BMO were manually segmented in each radial B-scan. Three SD-OCT parameters were computed globally and sectorally: (1) circumpapillary retinal nerve fiber layer thickness (RNFLT); (2) BMO-horizontal rim width (BMO-HRW), the distance between BMO and ILM in the BMO reference plane; and (3) BMO-MRW, the minimum distance between BMO and ILM. Moorfields Regression Analysis (MRA) with CLST was performed globally and sectorally to yield MRA1 and MRA2, where “borderline” was classified as normal and abnormal, respectively. Main Outcome Measures Sensitivity, specificity, and likelihood ratios (LRs) for positive and negative test results (LR+/LR−). Results The median (interquartile range) age and mean deviation of patients and controls were 69.9 (64.3–76.9) and 65.0 (58.1–74.3) years and −3.92 (−7.87 to −1.62) and 0.33 (−0.32 to 0.98) dB, respectively. Globally, BMO-MRW yielded better diagnostic performance than the other parameters. At 95% specificity, the sensitivity of RNFLT, BMO-HRW, and BMO-MRW was 70%, 51%, and 81%, respectively. The corresponding LR+/LR− was 14.0/0.3, 10.2/0.5, and 16.2/0.2. Sectorally, at 95% specificity, the sensitivity of RNFLT ranged from 31% to 59%, of BMO-HRW ranged from 35% to 64%, and of BMO-MRW ranged from 54% to 79%. Globally and in all sectors, BMO-MRW performed better than MRA1 or MRA2. Conclusions The higher sensitivity at 95% specificity in early glaucoma of BMO-MRW compared with current BMO methods is significant, indicating a new structural marker for the detection and risk profiling of glaucoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical Epidemiology: A Basic Science for Clinical Medicine.
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-9-825_9 · Cited by 3,476
Users' guides to the medical literature
Guyatt, G. H. (1993) · JAMA · doi:10.1001/jama.270.17.2096 · Cited by 2,970
Clinical Epidemiology - a basic science for clinical medicine
Hoffbrand, B. I. (1992) · Postgraduate Medical Journal · doi:10.1136/pgmj.68.806.987-a · Cited by 783
Histology of the Human Eye: An Atlas and Textbook
(1972) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1972.tb88227.x · Cited by 634
How to Use an Article About a Diagnostic Test
Scales, C. D., Dahm, P., Sultan, S., Campbell-Scherer, D., & Devereaux, P. J. (2008) · Journal of Urology · doi:10.1016/j.juro.2008.04.026 · Cited by 456
A new generation of algorithms for computerized threshold perimetry, SITA
Bengtsson, B., Olsson, J., Heijl, A., & Rootzén, H. (1997) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.1997.tb00392.x · Cited by 431
Ability of Cirrus HD-OCT Optic Nerve Head Parameters to Discriminate Normal from Glaucomatous Eyes
Mwanza, J.-C., Oakley, J. D., Budenz, D. L., & Anderson, D. R. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.06.036 · Cited by 339
Comparison of optic nerve imaging methods to distinguish normal eyes from those with glaucoma.
Greaney, M. J., Hoffman, D. C., Garway‐Heath, D. F., Nakla, M., Coleman, A. L., & Caprioli, J. (2002) · PubMed · Cited by 315
Mwanza, J.-C., Chang, R. T., Budenz, D. L., Durbin, M. K., Gendy, M. G., Shi, W., & Feuer, W. J. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5222 · Cited by 300
Åsman, P. (1992) · Archives of Ophthalmology · doi:10.1001/archopht.1992.01080180084033 · Cited by 295
Reis, A. S. C., O'Leary, N., Yang, H., Sharpe, G. P., Nicolela, M. T., Burgoyne, C. F., & Chauhan, B. C. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9309 · Cited by 262
Self-citationStrouthidis, N. G., Fortune, B., Yang, H., Sigal, I. A., & Burgoyne, C. F. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5599 · Cited by 210
Self-citationHistology of the Human Eye: An Atlas and Textbook
Shoch, D. E. (1972) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1972.03190280059024 · Cited by 190
Abrams, L. S., Scott, I. U., Spaeth, G. L., Quigley, H. A., & Varma, R. (1994) · Ophthalmology · doi:10.1016/s0161-6420(94)31118-3 · Cited by 181
DeLeo´n-Ortega, J. E., Arthur, S. N., McGwin, G., Xie, A., Monheit, B. E., & Girkin, C. A. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-1239 · Cited by 170
Jansonius, N. M., Nevalainen, J., Selig, B., Zangwill, L. M., Sample, P. A., Budde, W. M., Jonas, J. B., Lagrèze, W. A., Airaksinen, P. J., Vonthein, R., et al. (2009) · Vision Research · doi:10.1016/j.visres.2009.04.029 · Cited by 155
Chen, T. C. (2009) · PubMed · Cited by 125
Strouthidis, N. G., Yang, H., Fortune, B. A., Downs, J. C., & Burgoyne, C. F. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2302 · Cited by 103
Self-citationChauhan, B. C., Nicolela, M. T., & Artes, P. H. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.04.031 · Cited by 98
Self-citationAgreement between Retinal Nerve Fiber Layer Measures from Spectralis and Cirrus Spectral Domain OCT
Patel, N. B., Wheat, J. L., Rodríguez, A. M. P., Tran, V. N., & Harwerth, R. S. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e318238c34e · Cited by 68
Rao, H. L., Leite, M. T., Weinreb, R. N., Zangwill, L. M., de Alencar, L. M., Sample, P. A., & Medeiros, F. A. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-5546 · Cited by 68
Pablo, L. E., Ferreras, A., Fogagnolo, P., Figus, M., & Pajarín, A. B. (2009) · Eye · doi:10.1038/eye.2009.14 · Cited by 31
Diagnostic Accuracy of the Heidelberg Retina Tomograph for Glaucoma
Healey, P. R., Lee, A. J., Aung, T., Wong, T. Y., & Mitchell, P. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.07.001 · Cited by 30
Girkin, C. A., DeLeón-Ortega, J., Xie, A., McGwin, G., Arthur, S. N., & Monheit, B. E. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.06.035 · Cited by 30
Resch, H., Deák, G. G., Pereira, I., & Vass, C. (2012) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2012.02385.x · Cited by 12
Cited by
The Pathophysiology and Treatment of Glaucoma: A Review
Weinreb, R. N., Aung, T., & Medeiros, F. A. (2014) · JAMA · doi:10.1001/jama.2014.3192 · Cited by 4,210
Jonas, J. B., Aung, T., Bourne, R. R., Bron, A. M., Ritch, R., & Panda-Jonas, S. (2017) · The Lancet · doi:10.1016/s0140-6736(17)31469-1 · Cited by 1,322
Weinreb, R. N., Leung, C. K. S., Crowston, J. G., Medeiros, F. A., Friedman, D. S., Wiggs, J. L., & Martin, K. R. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2016.67 · Cited by 632
Chauhan, B. C., & Burgoyne, C. F. (2013) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2013.04.016 · Cited by 278
Self-citationOptical coherence tomography imaging for glaucoma - today and tomorrow
Leung, C. K.-S. (2016) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000179 · Cited by 17
Metadata
- Authors
- Chauhan, B. C., O'Leary, N., AlMobarak, F. A., Reis, A. S. C., Yang, H., Sharpe, G. P., Hutchison, D. M., Nicolela, M. T., & Burgoyne, C. F.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2013-03
- Volume
- 120
- Issue
- 3
- Pages
- 535-543
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2016203464
- Cited by
- 384
- References
- 26
- FWCI
- 15.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.