The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Corneal Hysteresis as a Risk Factor for Glaucoma Progression: A Prospective Longitudinal Study
Open accessAbstract
Purpose To evaluate the role of corneal hysteresis (CH) as a risk factor for the rate of visual field progression in a cohort of glaucoma patients followed prospectively over time. Design Prospective observational cohort study. Participants The study group included 114 eyes of 68 glaucoma patients followed for an average of 4.0 ± 1.1 years. Visual fields were obtained with standard automated perimetry. Included eyes had a median number of 7 (range: 5 to 12) tests during follow-up. Methods CH measurements were acquired at baseline using the Ocular Response Analyzer (Reichert Instruments, Depew, NY, USA). Evaluation of rates of visual field change during follow-up was performed using the Visual Field Index (VFI). Linear mixed models were used to investigate the relationship between rates of visual field loss and baseline CH, baseline intraocular pressure (IOP) and central corneal thickness (CCT), while adjusting for potentially confounding factors. An interaction term between IOP and CH was included in the model to investigate whether the effect of IOP on rates of progression depended on the level of CH. Main Outcome Measures Effects of CH, IOP and CCT on rates of VFI loss over time. Results CH had a significant effect on rates of visual field progression over time. In the univariable model including only CH as a predictive factor along with time and their interaction, each 1mmHg lower CH was associated with 0.25%/year faster rate of VFI decline over time (P<0.001). The multivariable model showed that the effect of IOP on rates of progression depended on CH. Eyes with high IOP and low CH were at increased risk for having fast rates of disease progression. CH explained a larger proportion of the variation in slopes of VFI change than CCT (17.4% versus 5.2%, respectively). Conclusion CH measurements were significantly associated with risk of glaucoma progression. Eyes with lower CH had faster rates of visual field loss than those with higher CH. The prospective longitudinal design of this study supports the role of CH as an important factor to be considered in the assessment of the risk of progression in glaucoma patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Random-Effects Models for Longitudinal Data
Laird, N. M., & Ware, J. H. (1982) · Biometrics · doi:10.2307/2529876 · Cited by 8,923
Kass, M. A. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.6.701 · Cited by 3,705
(2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00538-9 · Cited by 2,780
Gordon, M. O. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.6.714 · Cited by 2,626
That BLUP is a Good Thing: The Estimation of Random Effects
Robinson, G. K. (1991) · Statistical Science · doi:10.1214/ss/1177011926 · Cited by 1,686
Predictors of Long-term Progression in the Early Manifest Glaucoma Trial
Leske, M. C., Heijl, A., Hyman, L., Bengtsson, B., Dong, L., & Yang, Z. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2007.03.016 · Cited by 1,363
Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
Luce, D. A. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.10.044 · Cited by 1,311
A framework for comparing structural and functional measures of glaucomatous damage
Hood, D. C., & Kardon, R. H. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.08.001 · Cited by 703
Measuring explained variation in linear mixed effects models
Xu, R. (2003) · Statistics in Medicine · doi:10.1002/sim.1572 · Cited by 541
Central Corneal Thickness and Corneal Hysteresis Associated With Glaucoma Damage
Congdon, N. G., Broman, A. T., Bandeen-Roche, K., Grover, D., & Quigley, H. A. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.12.007 · Cited by 507
Natural History of Open-Angle Glaucoma
Heijl, A., Bengtsson, B., Hyman, L., & Leske, M. C. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.06.042 · Cited by 394
A Visual Field Index for Calculation of Glaucoma Rate of Progression
Bengtsson, B., & Heijl, A. (2008) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2007.09.038 · Cited by 374
Results of the European Glaucoma Prevention Study
(2005) · Ophthalmology · doi:10.1016/j.ophtha.2004.11.030 · Cited by 323
Natural history of normal-tension glaucoma
Anderson, D. R., Drance, S. M., & Schulzer, M. (2001) · Ophthalmology · doi:10.1016/s0161-6420(00)00518-2 · Cited by 320
Wells, A. P., Garway-Heath, D. F., Poostchi, A., Wong, T., Chan, K. C. Y., & Sachdev, N. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-1556 · Cited by 265
Medeiros, F. A., Sample, P. A., Zangwill, L. M., Bowd, C., Aihara, M., & Weinreb, R. N. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(03)00484-7 · Cited by 248
Self-citationAfrican Descent and Glaucoma Evaluation Study (ADAGES)
Skaat, A., De Moraes, C. G., Bowd, C., Sample, P. A., Girkin, C. A., Medeiros, F. A., Ritch, R., Weinreb, R. N., Zangwill, L. M., & Liebmann, J. M. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.03.025 · Cited by 222
Self-citationBiomechanical Changes in the Sclera of Monkey Eyes Exposed to Chronic IOP Elevations
Girard, M. J. A., Suh, J.-K. F., Bottlang, M., Burgoyne, C. F., & Downs, J. C. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6927 · Cited by 221
Medeiros, F. A. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.10.1351 · Cited by 187
Self-citationCentral Corneal Thickness and Thickness of the Lamina Cribrosa in Human Eyes
Jonas, J. B., & Holbach, L. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0851 · Cited by 164
Sigal, I. A., Yang, H., Roberts, M. D., Burgoyne, C. F., & Downs, J. C. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5500 · Cited by 162
Kaushik, S., Pandav, S. S., Banger, A., Aggarwal, K., & Gupta, A. (2012) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2011.10.032 · Cited by 153
Medeiros, F. A., de Alencar, L. M., Zangwill, L. M., Sample, P. A., & Weinreb, R. N. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2008.12.062 · Cited by 109
Self-citationBrandt, J. D., Gordon, M. O., Gao, F., Beiser, J. A., Miller, J. P., & Kass, M. A. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.03.018 · Cited by 101
African Descent and Glaucoma Evaluation Study (ADAGES)
Racette, L. (2010) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2010.58 · Cited by 94
Corneal Hysteresis and Visual Field Asymmetry in Open Angle Glaucoma
Anand, A., Moraes, C. G. V. D., Teng, C. C., Tello, C. A., Liebmann, J. M., & Ritch, R. H. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-5580 · Cited by 91
Corneal hysteresis measured with the Ocular Response Analyzer® in normal and glaucomatous eyes
Abitbol, O., Bouden, J., Doan, S., Hoang-Xuan, T., & Gatinel, D. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2009.01554.x · Cited by 90
Changes in Central Corneal Thickness over Time
Brandt, J. D., Gordon, M. O., Beiser, J. A., Lin, S. C., Alexander, M., & Kass, M. A. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2008.02.001 · Cited by 81
A Clinical Description of Ocular Response Analyzer Measurements
Lau, W., & Pye, D. C. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-6763 · Cited by 65
Multivariate longitudinal models for complex change processes
Beckett, L. A., Tancredi, D. J., & Wilson, R. S. (2004) · Statistics in Medicine · doi:10.1002/sim.1712 · Cited by 60
Mangouritsas, G., Mangouritsas, G., Mantzounis, & Alexopoulos (2011) · Clinical ophthalmology · doi:10.2147/opth.s23086 · Cited by 24
(2019) · Springer eBooks · doi:10.1007/978-981-13-2733-9 · Cited by 23
Central Corneal Thickness and Thickness of the Lamina Cribrosa and Peripapillary Sclera in Monkeys
Jonas, J. B. (2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2009.243 · Cited by 16
Cited by
Weinreb, R. N., Leung, C. K. S., Crowston, J. G., Medeiros, F. A., Friedman, D. S., Wiggs, J. L., & Martin, K. R. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2016.67 · Cited by 632
Self-citationPrimary Open-Angle Glaucoma Preferred Practice Pattern®
Gedde, S. J., Vinod, K., Wright, M. M., Muir, K. W., Lind, J. T., Chen, P. P., Li, T., & Mansberger, S. L. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.10.022 · Cited by 474
Kwok, S., Clayson, K., Hazen, N., Pan, X., Ma, Y., Hendershot, A. J., & Liu, J. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.13.33 · Cited by 19
Metadata
- Authors
- Medeiros, F. A., Meira-Freitas, D., Lisboa, R., Kuang, T.-M., Zangwill, L. M., & Weinreb, R. N.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2013-08
- Volume
- 120
- Issue
- 8
- Pages
- 1533-1540
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2070829567
- Cited by
- 283
- References
- 33
- FWCI
- 13.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.