CoChat

Pseudodrusen and Incidence of Late Age-Related Macular Degeneration in Fellow Eyes in the Comparison of Age-Related Macular Degeneration Treatments Trials

Open access
Zhou, Qiang, Daniel, Ebenezer, Maguire, Maureen G., Grunwald, Juan E., Martin, E. Revell, Martin, Daniel F., Ying, Gui-shuang · 2016 · Ophthalmology
Cited by 108

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Purpose To evaluate the association between pseudodrusen and incidence of late age-related macular degeneration (AMD) in fellow eyes of patients with unilateral neovascular AMD (nAMD). Design Cohort study within the Comparison of AMD Treatments Trials (CATT). Participants Patients with neither nAMD nor geographic atrophy (GA) in the fellow eye at baseline. Methods Presence and type (dot, reticular, or confluent) of baseline pseudodrusen were assessed using digital color fundus photography (CFP) viewed under full color, green channel, and blue channel; red-free images; and fluorescein angiography (FA). Incidence of nAMD was based on monthly clinical examination and reading center evaluation of images at years 1 and 2. Incidence of GA was based on reading center evaluation of CFP and FA images at years 1 and 2. Associations of baseline pseudodrusen with incident nAMD and GA were summarized with adjusted risk ratios (aRRs) and their 95% confidence intervals (CIs) from multivariate Cox models, with adjustment of covariates identified through backward stepwise selection. Main Outcome Measures Incident nAMD and GA. Results Among 620 fellow eyes, 176 (28.4%) had baseline pseudodrusen (55% dot, 82% reticular, 35% confluent). Within 2 years, nAMD occurred in 54 eyes (30.7%) with pseudodrusen and in 72 eyes (16.2%) without pseudodrusen (aRR, 2.05; 95% CI, 1.43–2.93); GA occurred in 27 eyes (15.3%) with pseudodrusen and in 37 eyes (8.3%) without pseudodrusen (aRR, 1.89; 95% CI, 1.13–3.17); late AMD occurred in 73 eyes (41.5%) with pseudodrusen and in 101 eyes (22.8%) without pseudodrusen (aRR, 2.07; 95% CI, 1.51–2.83). Dot pseudodrusen were associated independently with nAMD (aRR, 2.53; 95% CI, 1.60–4.00), whereas confluent pseudodrusen were associated independently with GA (aRR, 4.35; 95% CI, 1.69–11.2). Eyes with pseudodrusen had increased incidence of late AMD regardless of whether the Age-Related Eye Diseases Study (AREDS) severity score was 2 (28.7% vs. 10.3%), 3 (34.9% vs. 13.7%), or 4 (50.5% vs. 32.0%). Conclusions In fellow eyes of CATT participants, pseudodrusen were associated independently with a higher incidence of both nAMD and GA. Dot pseudodrusen were associated with nAMD, whereas confluent pseudodrusen were associated with GA. Pseudodrusen should be considered along with the AREDS severity score for predicting late AMD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ophtha.2016.02.043

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 108

Metadata

Authors
Zhou, Q., Daniel, E., Maguire, M. G., Grunwald, J. E., Martin, E. R., Martin, D. F., & Ying, G.-S.
Venue
Ophthalmology
Publisher
Elsevier BV
Published
2016-07
Volume
123
Issue
7
Pages
1530-1540
ISSN
0161-6420 (ISSN-L)
OpenAlex
W2323021211
Cited by
108
References
6
FWCI
13.03
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.