Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 360

The DOI matches its Crossref record; 174 of the 174 references it cites were found in a registry or an index.

Spectral-Domain OCT Measurements in Alzheimer’s Disease

Open access
Chan, Victor T.T., Sun, Zihan, Tang, Shumin, Chen, Li Jia, Wong, Adrian, Tham, Clement C., Wong, Tien Y., Chen, Christopher, Ikram, M. Kamran, Whitson, Heather E., Lad, Eleonora M., Mok, Vincent C.T., Cheung, Carol Y.·2019·Ophthalmology

Abstract

TOPIC OCT is a noninvasive tool to measure specific retinal layers in the eye. The relationship of retinal spectral-domain (SD) OCT measurements with Alzheimer's disease (AD) and mild cognitive impairment (MCI) remains unclear. Hence, we conducted a systematic review and meta-analysis to examine the SD OCT measurements in AD and MCI. CLINICAL RELEVANCE Current methods of diagnosing early AD are expensive and invasive. Retinal measurements of SD OCT, which are noninvasive, technically simple, and inexpensive, are potential biomarkers of AD. METHODS We conducted a literature search in PubMed and Excerpta Medica Database to identify studies published before December 31, 2017, that assessed the associations between AD, MCI, and measurements of SD OCT: ganglion cell-inner plexiform layer (GC-IPL), ganglion cell complex (GCC), macular volume, and choroidal thickness, in addition to retinal nerve fiber layer (RNFL) and macular thickness. We used a random-effects model to examine these relationships. We also conducted meta-regression and assessed heterogeneity, publication bias, and study quality. RESULTS We identified 30 eligible studies, involving 1257 AD patients, 305 MCI patients, and 1460 controls, all of which were cross-sectional studies. In terms of the macular structure, AD patients showed significant differences in GC-IPL thickness (standardized mean difference [SMD], -0.46; 95% confidence interval [CI], -0.80 to -0.11; I2 = 71%), GCC thickness (SMD, -0.84; 95% CI, -1.10 to -0.57; I2 = 0%), macular volume (SMD, -0.58; 95% CI, -1.03 to -0.14; I2 = 80%), and macular thickness of all inner and outer sectors (SMD range, -0.52 to -0.74; all P < 0.001) when compared with controls. Peripapillary RNFL thickness (SMD, -0.67; 95% CI, -0.95 to -0.38; I2 = 89%) and choroidal thickness (SMD range, -0.88 to -1.03; all P < 0.001) also were thinner in AD patients. CONCLUSIONS Our results confirmed the associations between retinal measurements of SD OCT and AD, highlighting the potential usefulness of SD OCT measurements as biomarkers of AD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ophtha.2018.08.009

Cites

174 of 174 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 174 references

Cited by

See all 360

Metadata

Authors
Chan, V. T. T., Sun, Z., Tang, S., Chen, L. J., Wong, A., Tham, C. C., Wong, T. Y., Chen, C., Ikram, M. K., Whitson, H. E., Lad, E. M., Mok, V. C. T., & Cheung, C. Y.
Venue
Ophthalmology
Publisher
Elsevier BV
Published
2019-04
Volume
126
Issue
4
Pages
497-510
ISSN
0161-6420 (ISSN-L)
OpenAlex
W2886040290
Cited by
360
References
174
FWCI
20.64
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spectral-Domain OCT Measurements in Alzheimer’s Disease. https://app.cochat.ai/papers/10.1016/j.ophtha.2018.08.009
The paper
Chan, V. T. T., Sun, Z., Tang, S., Chen, L. J., Wong, A., Tham, C. C., Wong, T. Y., Chen, C., Ikram, M. K., Whitson, H. E., Lad, E. M., Mok, V. C. T., & Cheung, C. Y. (2019). Spectral-Domain OCT Measurements in Alzheimer’s Disease. Ophthalmology. https://doi.org/10.1016/j.ophtha.2018.08.009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.