Two-Year Clinical Trial of the Low-Concentration Atropine for Myopia Progression (LAMP) Study
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
PURPOSE To evaluate the efficacy and safety of 0.05%, 0.025%, and 0.01% atropine eye drops over 2 years to determine which is the optimal concentration for longer-term myopia control. DESIGN Randomized, double-masked trial extended from the Low-Concentration Atropine for Myopia Progression (LAMP) Study. PARTICIPANTS Three hundred eighty-three of 438 children (87%) aged 4 to 12 years with myopia of at least -1.0 diopter (D) originally randomized to receive atropine 0.05%, 0.025%, 0.01%, or placebo once daily in both eyes in the LAMP phase 1 study were continued in this extended trial (phase 2). METHODS Children in the placebo group (phase 1) were switched to receive 0.05% atropine from the beginning of the second-year follow-up, whereas those in the 0.05%, 0.025%, and 0.01% atropine groups continued with the same regimen. Cycloplegic refraction, axial length (AL), accommodation amplitude, photopic and mesopic pupil diameter, and best-corrected visual acuity were measured at 4-month intervals. MAIN OUTCOME MEASURES Changes in spherical equivalent (SE) and AL and their differences between groups. RESULTS Over the 2-year period, the mean SE progression was 0.55±0.86 D, 0.85±0.73 D, and 1.12±0.85 D in the 0.05%, 0.025%, and 0.01% atropine groups, respectively (P = 0.015, P < 0.001, and P = 0.02, respectively, for pairwise comparisons), with mean AL changes over 2 years of 0.39±0.35 mm, 0.50±0.33 mm, and 0.59±0.38 mm (P = 0.04, P < 0.001, and P = 0.10, respectively). Compared with the first year, the second-year efficacy of 0.05% and 0.025% atropine remained similar (P >0.1), but improved mildly in the 0.01% atropine group (P = 0.04). For the phase 1 placebo group, the myopia progression was reduced significantly after switching to 0.05% atropine (SE change, 0.18 D in second year vs. 0.82 D in first year [P < 0.001]; AL elongated 0.15 mm in second year vs. 0.43 mm in first year [P < 0.001]). Accommodation loss and change in pupil size in all concentrations remained similar to the first-year results and were well tolerated. Visual acuity and vision-related quality of life remained unaffected. CONCLUSIONS Over 2 years, the efficacy of 0.05% atropine observed was double that observed with 0.01% atropine, and it remained the optimal concentration among the studied atropine concentrations in slowing myopia progression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526
Longitudinal data analysis using generalized linear models
LIANG, K.-Y., & ZEGER, S. L. (1986) · Biometrika · doi:10.1093/biomet/73.1.13 · Cited by 18,550
Jakobsen, J. C., Gluud, C., Wetterslev, J., & Winkel, P. (2017) · BMC Medical Research Methodology · doi:10.1186/s12874-017-0442-1 · Cited by 2,747
Statistical Analysis of Correlated Data Using Generalized Estimating Equations: An Orientation
Hanley, J. A. (2003) · American Journal of Epidemiology · doi:10.1093/aje/kwf215 · Cited by 2,185
Chia, A., Chua, W.-H., Cheung, Y.-B., Wong, W.-L., Lingham, A., Fong, A., & Tan, D. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.07.031 · Cited by 852
Efficacy Comparison of 16 Interventions for Myopia Control in Children
Huang, J., Wen, D., Wang, Q., McAlinden, C., Flitcroft, I., Chen, H., Saw, S. M., Chen, H., Bao, F., Zhao, Y., et al. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2015.11.010 · Cited by 752
Low-Concentration Atropine for Myopia Progression (LAMP) Study
Yam, J. C., Jiang, Y., Tang, S. M., Law, A. K. P., Chan, J. J., Wong, E., Ko, S. T., Young, A. L., Tham, C. C., Chen, L. J., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2018.05.029 · Cited by 724
Self-citationPrevalence and risk factors for refractive errors in adult Chinese in Singapore.
Wong, T. Y., Foster, P. J., Hee, J., Ng, T. P., Tielsch, J. M., Chew, S., Johnson, G. J., & Seah, S. K. W. (2000) · PubMed · Cited by 722
Five-Year Clinical Trial on Atropine for the Treatment of Myopia 2
Chia, A., Lu, Q.-S., & Tan, D. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2015.07.004 · Cited by 649
Refractive Errors in an Elderly Japanese Population
Sawada, A., Tomidokoro, A., Araie, M., Iwase, A., & Yamamoto, T. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.03.075 · Cited by 385
Generalized Estimating Equations in Longitudinal Data Analysis: A Review and Recent Developments
Wang, M. (2014) · Advances in Statistics · doi:10.1155/2014/303728 · Cited by 313
Update in myopia and treatment strategy of atropine use in myopia control
Wu, P.-C., Chuang, M.-N., Choi, J., Chen, H., Wu, G., Ohno-Matsui, K., Jonas, J. B., & Cheung, C. M. G. (2019) · Eye · doi:10.1038/s41433-018-0139-7 · Cited by 239
Maximum Atropine Dose Without Clinical Signs or Symptoms
Cooper, J., Eisenberg, N., Schulman, E., & Wang, F. M. (2013) · Optometry and Vision Science · doi:10.1097/opx.0000000000000037 · Cited by 111
The Lowdown on Low-Concentration Atropine for Myopia Progression
Sankaridurg, P. R., & Tran, H. D. M. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.08.024 · Cited by 19
Cited by
Baird, P. N., Saw, S.-M., Lanca, C., Guggenheim, J. A., Smith III, E. L., Zhou, X., Matsui, K.-O., Wu, P.-C., Sankaridurg, P., Chia, A., et al. (2020) · Nature Reviews Disease Primers · doi:10.1038/s41572-020-00231-4 · Cited by 838
IMI Prevention of Myopia and Its Progression
Jonas, J. B., Ang, M., Cho, P., Guggenheim, J. A., He, M. G., Jong, M., Logan, N. S., Liu, M., Morgan, I., Ohno-Matsui, K., et al. (2021) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.62.5.6 · Cited by 475
Zhang, X., Cheung, S. S. L., Chan, H.-N., Zhang, Y., Wang, Y. M., Yip, B. H., Kam, K. W., Yu, M., Cheng, C.-Y., Young, A. L., et al. (2022) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2021-319307 · Cited by 177
Self-citation
Metadata
- Authors
- Yam, J. C., Li, F. F., Zhang, X., Tang, S. M., Yip, B. H. K., Kam, K. W., Ko, S. T., Young, A. L., Tham, C. C., Chen, L. J., & Pang, C. P.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 127
- Issue
- 7
- Pages
- 910-919
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2995569484
- Cited by
- 317
- References
- 14
- FWCI
- 21.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.