CoChat

Deep Learning–Based Algorithms in Screening of Diabetic Retinopathy: A Systematic Review of Diagnostic Performance

Open access
Nielsen, Katrine B., Lautrup, Mie L., Andersen, Jakob K.H., Savarimuthu, Thiusius R., Grauslund, Jakob · 2019 · Ophthalmology Retina
Cited by 118

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

TOPIC Diagnostic performance of deep learning-based algorithms in screening patients with diabetes for diabetic retinopathy (DR). The algorithms were compared with the current gold standard of classification by human specialists. CLINICAL RELEVANCE Because DR is a common cause of visual impairment, screening is indicated to avoid irreversible vision loss. Automated DR classification using deep learning may be a suitable new screening tool that could improve diagnostic performance and reduce manpower. METHODS For this systematic review, we aimed to identify studies that incorporated the use of deep learning in classifying full-scale DR in retinal fundus images of patients with diabetes. The studies had to provide a DR grading scale, a human grader as a reference standard, and a deep learning performance score. A systematic search on April 5, 2018, through MEDLINE and Embase yielded 304 publications. To identify potentially missed publications, the reference lists of the final included studies were manually screened, yielding no additional publications. The Quality Assessment of Diagnostic Accuracy Studies 2 tool was used for risk of bias and applicability assessment. RESULTS By using objective selection, we included 11 diagnostic accuracy studies that validated the performance of their deep learning method using a new group of patients or retrospective datasets. Eight studies reported sensitivity and specificity of 80.28% to 100.0% and 84.0% to 99.0%, respectively. Two studies report accuracies of 78.7% and 81.0%. One study provides an area under the receiver operating curve of 0.955. In addition to diagnostic performance, one study also reported on patient satisfaction, showing that 78% of patients preferred an automated deep learning model over manual human grading. CONCLUSIONS Advantages of implementing deep learning-based algorithms in DR screening include reduction in manpower, cost of screening, and issues relating to intragrader and intergrader variability. However, limitations that may hinder such an implementation particularly revolve around ethical concerns regarding lack of trust in the diagnostic accuracy of computers. Considering both strengths and limitations, as well as the high performance of deep learning-based algorithms, automated DR classification using deep learning could be feasible in a real-world screening scenario.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.oret.2018.10.014

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Nielsen, K. B., Lautrup, M. L., Andersen, J. K. H., Savarimuthu, T. R., & Grauslund, J.
Venue
Ophthalmology Retina
Publisher
Elsevier BV
Published
2019-04
Volume
3
Issue
4
Pages
294-304
ISSN
2468-6530 (ISSN-L)
OpenAlex
W2899170201
Cited by
118
References
10
FWCI
1.74
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.