CoChat

Is there any difference between conventional, passive and active self-ligating brackets? A systematic review and network meta-analysis

Open access
Maizeray, Raphaëlle, Wagner, Delphine, Lefebvre, François, Lévy-Bénichou, Hélène, Bolender, Yves · 2021 · International Orthodontics
Cited by 46

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

AIM To test the null hypothesis that there was no difference in treatment efficiency between therapies undertaken with conventional (CBs), passive self-ligating (PSLBs) or active self-ligating (ASLBs) brackets. MATERIALS AND METHODS An electronic search was performed in 3 data bases (Pubmed, Web of Science, Cochrane Library) from their origin up to January 2019. Additional references were hand searched. Search was strictly restricted to randomized controlled trials (RCTs) and split-mouth design studies (SMDs). RCTs and SMDs were initially processed separately and subsequently combined in a network meta-analysis. The following variables were evaluated: treatment duration, number of visits, occlusal outcomes, alignment rate, transverse arch dimensional changes, incisor position modification, rate of space closure, anchorage loss, bond failure, root resorption, perception of discomfort during the initial phase of alignment, time to ligate in or to untie an archwire, periodontal variables, quality of life. RESULTS On 229 papers, 30 RCTs and 9 SMDs were finally included in this study. Out of 85 comparisons, 16 only revealed statistically significant differences. It was quicker to untie and ligate an 0.014 NiTi arch from/in 6 ASLBs anterior ceramic brackets compared to 6 ceramic CBs. It was also more painful to insert and remove an 0.019×0.025 SS wire in/from PSLB's brackets compared to CB's attachments. Compared to conventional brackets, there was less maxillary incisor proclination with PSLBs in non-extraction cases. Moreover, there was less bleeding on probing 4-5 weeks after bonding with PSLBs compared to CBs brackets. The only significant difference between ASLBs and PSLBs was that alignment was 10 days faster with active self-ligating braces compared with passive self-ligating braces even if treatment duration between ASLBs and PSLBs was not significantly different. The network meta-analysis revealed that IMPA was greater in extractions cases with CBs compared with both ASLBs (+2,5°) and PSLBs (+1,6°). CONCLUSIONS The vast majority of the studied variables did not show any significant differences between the three types of brackets. The most significant findings were that it was quicker to insert and remove archwires from ASLBs compared to CBs, and it was more painful to insert and remove an 0.019×0.025" stainless steel wire in/from PSLBs compared to CBs. The major difference between ASLBs and PSLBs was that alignment was 10 days faster with active self-ligating braces compared with passive self-ligating braces even if treatment duration between ASLBs and PSLBs was not significantly different. Most of the claims put forward by the suppliers were not substantiated by our network meta-analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ortho.2021.09.005

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 46

Metadata

Authors
Maizeray, R., Wagner, D., Lefebvre, F., Lévy-Bénichou, H., & Bolender, Y.
Venue
International Orthodontics
Publisher
Elsevier BV
Published
2021-12
Volume
19
Issue
4
Pages
523-538
ISSN
1761-7227 (ISSN-L)
OpenAlex
W3203314527
Cited by
46
References
6
FWCI
2.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.