Tibio‐femoral loading during human gait and stair climbing
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Surgical intervention of the knee joint routinely endeavors to recreate a physiologically normal joint loading environment. The loading conditions resulting from osteotomies, fracture treatment, ligament replacements, and arthroplasties of the knee are considered to have an impact on the long term clinical outcome; however, knowledge regarding in vivo loading conditions is limited. Using a previously validated musculoskeletal lower limb model, we predicted the tibio‐femoral joint contact forces that occur in the human knee during the common daily activities of walking and stair climbing. The average resultant peak force during walking was 3.1 times body weight (BW) across four total hip arthroplasty patients. Inter‐individual variations proved larger than the variation of forces for each patient repeating the same task. Forces through the knee were considerably larger during stair climbing than during walking: the average resultant peak force during stair climbing was 5.4 BW although peaks of up to 6.2 BW were calculated for one particular patient. Average anteroposterior peak shear components of 0.6 BW were determined during walking and 1.3 BW during stair climbing. These results confirm both the joint contact forces reported in the literature and the importance of muscular activity in creating high forces across the joint. The magnitudes of these forces, specifically in shear, have implications for all forms of surgical intervention in the knee. The data demonstrate that high contact and shear forces are generated during weight bearing combined with knee flexion angles greater than approximately 15°. Clinically, the conditions that produce these larger contact forces should be avoided during post‐operative rehabilitation. © 2003 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hip contact forces and gait patterns from routine activities
Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J., & Duda, G. N. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00040-9 · Cited by 2,215
Self-citationA physiologically based criterion of muscle force prediction in locomotion
Crowninshield, R. D., & Brand, R. A. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90035-x · Cited by 1,427
Hip joint loading during walking and running, measured in two patients
Bergmann, G., Graichen, F., & Rohlmann, A. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90058-m · Cited by 1,276
Self-citationWoo, S. L.-Y., Hollis, J. M., Adams, D. J., Lyon, R. M., & Takai, S. (1991) · The American Journal of Sports Medicine · doi:10.1177/036354659101900303 · Cited by 1,196
Biomechanical Analysis of an Anatomic Anterior Cruciate Ligament Reconstruction
Yagi, M., Wong, E. K., Kanamori, A., Debski, R. E., Fu, F. H., & Woo, S. L.-Y. (2002) · The American Journal of Sports Medicine · doi:10.1177/03635465020300050501 · Cited by 988
Static vs dynamic loads as an influence on bone remodelling
Lanyon, L. E., & Rubin, C. T. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90003-4 · Cited by 887
Static and dynamic optimization solutions for gait are practically equivalent
Anderson, F. C., & Pandy, M. G. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00155-x · Cited by 788
Increased knee joint loads during walking are present in subjects with knee osteoarthritis
Baliunas, A. J., Hurwitz, D. E., Ryals, A. B., Karrar, A., Case, J. P., Block, J. A., & Andriacchi, T. P. (2002) · Osteoarthritis and Cartilage · doi:10.1053/joca.2002.0797 · Cited by 715
Effects of Mechanical Factors on the Fracture Healing Process
Claes, L. E., Heigele, C. A., Neidlinger-Wilke, C., Kaspar, D., Seidl, W., Margevicius, K. J., & Augat, P. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00015 · Cited by 705
Early Failures in Total Knee Arthroplasty
Fehring, T. K., Odum, S., Griffin, W. L., Mason, J. B., & Nadaud, M. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200111000-00041 · Cited by 646
Cited by
Loading of the Knee Joint during Activities of Daily Living Measured In Vivo in Five Subjects
Kutzner, I., Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., & Bergmann, G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.046 · Cited by 798
Grand challenge competition to predict in vivo knee loads
Fregly, B. J., Besier, T. F., Lloyd, D. G., Delp, S. L., Banks, S. A., Pandy, M. G., & D'Lima, D. D. (2012) · Journal of Orthopaedic Research · doi:10.1002/jor.22023 · Cited by 596
Standardized Loads Acting in Hip Implants
Bergmann, G., Bender, A., Dymke, J., Duda, G., & Damm, P. (2016) · PLOS ONE · doi:10.1371/journal.pone.0155612 · Cited by 562
Self-citationMusculoskeletal disorders associated with obesity: a biomechanical perspective
Wearing, S. C., Hennig, E. M., Byrne, N. M., Steele, J. R., & Hills, A. P. (2006) · Obesity Reviews · doi:10.1111/j.1467-789x.2006.00251.x · Cited by 521
Biomechanical considerations in the pathogenesis of osteoarthritis of the knee
Heijink, A., Gomoll, A. H., Madry, H., Drobnič, M., Filardo, G., Espregueira‐Mendes, J., & Van Dijk, C. N. (2012) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-011-1818-0 · Cited by 416
Standardized Loads Acting in Knee Implants
Bergmann, G., Bender, A., Graichen, F., Dymke, J., Rohlmann, A., Trepczynski, A., Heller, M. O., & Kutzner, I. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086035 · Cited by 382
Self-citationMuscle and external load contribution to knee joint contact loads during normal gait
Winby, C. R., Lloyd, D. G., Besier, T. F., & Kirk, T. B. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.019 · Cited by 374
Shelburne, K. B., Torry, M. R., & Pandy, M. G. (2006) · Journal of Orthopaedic Research · doi:10.1002/jor.20255 · Cited by 366
Pobloth, A.-M., Checa, S., Razi, H., Petersen, A., Weaver, J. C., Schmidt-Bleek, K., Windolf, M., Tatai, A. Á., Roth, C. P., Schaser, K.-D., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aam8828 · Cited by 312
Self-citationEffect of posterior tibial slope on knee biomechanics during functional activity
Shelburne, K. B., Kim, H., Sterett, W. I., & Pandy, M. G. (2011) · Journal of Orthopaedic Research · doi:10.1002/jor.21242 · Cited by 293
Knee joint loading during gait in healthy controls and individuals with knee osteoarthritis
Kumar, D., Manal, K. T., & Rudolph, K. S. (2013) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2012.11.008 · Cited by 257
Knee Adduction Moment and Medial Contact Force – Facts about Their Correlation during Gait
Kutzner, I., Trepczynski, A., Heller, M. O., & Bergmann, G. (2013) · PLoS ONE · doi:10.1371/journal.pone.0081036 · Cited by 256
Self-citationUpdate on the Role of Muscle in the Genesis and Management of Knee Osteoarthritis
Bennell, K. L., Wrigley, T. V., Hunt, M. A., Lim, B.-W., & Hinman, R. S. (2013) · Rheumatic Disease Clinics of North America · doi:10.1016/j.rdc.2012.11.003 · Cited by 254
Nagura, T., Matsumoto, H., Kiriyama, Y., Chaudhari, A., & Andriacchi, T. P. (2006) · Journal of Applied Biomechanics · doi:10.1123/jab.22.4.305 · Cited by 91
Tibiofemoral joint contact forces and knee kinematics during squatting
Smith, S. M., Cockburn, R. A., Hemmerich, A., Li, R. M., & Wyss, U. P. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.05.004 · Cited by 72
Metadata
- Authors
- Taylor, W. R., Heller, M. O., Bergmann, G., & Duda, G. N.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2004-05
- Volume
- 22
- Issue
- 3
- Pages
- 625-632
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2016476372
- Cited by
- 366
- References
- 34
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.