Tibiofemoral joint contact force in deep knee flexion and its consideration in knee osteoarthritis and joint replacement

Nagura, Takeo, Matsumoto, Hideo, Kiriyama, Yoshimori, Chaudhari, Ajit, Andriacchi, Thomas P.·2006·Journal of Applied Biomechanics

Abstract

The aim of the study was to estimate the tibiofemoral joint force in deep flexion to consider how the mechanical load affects the knee. We hypothesize that the joint force should not become sufficiently large to damage the joint under normal contact area, but should become deleterious to the joint under the limited contact area. Sixteen healthy knees were analyzed using a motion capture system, a force plate, a surface electromyography, and a knee model, and then tibiofemoral joint contact forces were calculated. Also, a contact stress simulation using the contact areas from the literature was performed. The peak joint contact forces (M +/- SD) were 4566 +/- 1932 N at 140 degrees in rising from full squat and 4479 +/- 1478 N at 90 degrees in rising from kneeling. Under normal contact area, the tibiofemoral contact stresses in deep flexion were less than 5 MPa and did not exceed the stress to damage the cartilage. The contact stress simulation suggests that knee prosthesis having the contact area smaller than 200 mm2 may be problematic since the contact stress in deep flexion would become larger than 21 MPa, and it would lead damage or wear of the polyethylene.

Integrity signals

Registry

Crossref · 10.1123/jab.22.4.305

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • High compressive loads in the tibiofemoral joint can worsen osteoarthritis by increasing stress/strain on internal structures (e.g., articular cartilage and menisci).

    “High compressive loads in the tibiofemoral joint can worsen osteoarthritis by increasing stress/strain on internal structures (e.g., articular cartilage and menisci).65,66”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Nagura, T., Matsumoto, H., Kiriyama, Y., Chaudhari, A., & Andriacchi, T. P.
Affiliations
  • Keio University (JP)
  • The Ohio State University (US)
  • Stanford University (US)
Venue
Journal of Applied Biomechanics
Published
2006-11
Volume
22
Issue
4
Pages
305-313
ISSN
  • 1065-8483 (ISSN-L)
  • 1543-2688
OpenAlex
W2103008683
Cited by
91
References
34
Citations by year
2026: 5 · 2025: 8 · 2024: 5 · 2023: 1 · 2022: 7 · 2021: 7 · 2020: 7 · 2019: 6 · 2018: 3 · 2017: 5 · 2016: 4 · 2015: 5 · 2014: 2 · 2013: 5 · 2012: 5
FWCI
3.37
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Applied Biomechanics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
  • Health Sciences › Medicine › Rheumatology › Osteoarthritis Treatment and Mechanisms
Keywords
deep knee flexion, knee osteoarthritis, knee arthroplasty, contact stress, cartilage damage, polyethylene wear, squatting, kneeling, contact area, knee prosthesis design
MeSH terms
Adult, Computer Simulation, Female, Femur, Humans, Knee Joint, Male, Models, Biological, Movement, Muscle Contraction, Posture, Stress, Mechanical, Surface Properties, Tibia, Arthroplasty, Replacement, Knee, Osteoarthritis, Knee

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review