The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws
Abstract
Internal fixators are a new class of implants designed to preserve the periosteal blood supply of the bone. In contrast to conventional plate fixation in which the screws have spherical heads and are loaded mainly by axial pullout forces, screws in internal fixators are “locked” within the plate and therefore subjected to axial as well as bending loads. In this study the ultimate loads of screws of a commercially available internal fixator system were tested in a pullout (n = 72) and cantilever bending mode (n = 72) in metaphyseal and diaphyseal regions of four pairs of human tibiae with different bone qualities. Cortical thickness and cancellous bone density were determined at the screw insertion sites. Stepwise multiple linear regression revealed that cortical thickness and cancellous density can explain 93% and 98% of the variance of the ultimate load of the screws in an axial pullout and cantilever bending mode. Screws in internal fixators are better suited to transmit shear forces and thereby make better use of the strength potential of bone than screws used in conventional plate fixation: this is especially advantageous when bone strength is reduced, e.g. due to osteoporosis. © 2004 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401
Cited by
Animal models for fracture treatment in osteoporosis
Egermann, M., Goldhahn, J., & Schneider, E. (2005) · Osteoporosis International · doi:10.1007/s00198-005-1859-7 · Cited by 262
Self-citation
Metadata
- Authors
- Seebeck, J., Goldhahn, J., Städele, H., Messmer, P., Morlock, M. M., & Schneider, E.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2004-11
- Volume
- 22
- Issue
- 6
- Pages
- 1237-1242
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2069131237
- Cited by
- 166
- References
- 1
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws. https://app.cochat.ai/papers/10.1016/j.orthres.2004.04.001
- The paper
- Seebeck, J., Goldhahn, J., Städele, H., Messmer, P., Morlock, M. M., & Schneider, E. (2004). Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws. Journal of Orthopaedic Research. https://doi.org/10.1016/j.orthres.2004.04.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.