Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
We evaluated the orthogonal mechanical properties of human trabecular bone from the major metaphyseal regions with materials testing and quantitative computed tomography (CT). The proximal tibia, distal femur, proximal femur, distal radius, and proximal humerus from fresh cadaver specimens between the ages of 55 and 70 years were excised and prepared for experimentation. The bones were embedded and scanned at 1 or 1.5 mm intervals on a Technicare HPS 1440 and GE 9800 CT scanner. After scanning, the bones were sectioned, producing 8‐mm cubes of trabecular bone which were mechanically tested in uniaxial compression at a strain rate of 1%/s. The testing sequence consisted of preyield tests in two of the three orthogonal directions and failure in the third. After testing, the cubes were evaluated for apparent density and ash weight. The results of the study show that the strength and stiffness of trabecular bone varies significantly within metaphyseal regions and from metaphysis to metaphysis. The power and significance of relationships between density and modulus varied as a function of metaphyseal location. Both linear and nonlinear models were significant, suggesting that trabecular deformation occurs in response to both axial and bending loads. Finally, the need for architectural measures of trabecular bone to predict mechanical properties is emphasized.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“The anisotropy that trabecular bone exhibits in microstructure is also present in elastic modulus (89) and strength (92).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The mechanics of three-dimensional cellular materials
Gibson, I. J., & Ashby, M. F. (1982) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1982.0088 · Cited by 1,885
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687
Self-citationPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Physical properties of trabecular bone
Galante, J., Rostoker, W., & Ray, R. D. (1970) · Calcified Tissue Research · doi:10.1007/bf02017552 · Cited by 302
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
Goldstein, S. A., Wilson, D. L., Sonstegard, D. A., & Matthews, L. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90097-0 · Cited by 292
Self-citationMechanical Properties of Trabecular Bone from the Proximal Femur: A Quantitative CT Study
Lotz, J. C., Gerhart, T. N., & Hayes, W. C. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199001000-00020 · Cited by 284
Research works printed but not linked: 4
- Evans FG, 1961, Biomechanical Studies of the Musculoskeletal System, 49
- Wolff J, 1892, Das Gestez der Transformation der Knochen
- Yokoo S, 1952, Compression test of the cancellous bone, J Kyoto Pref Med Univ, 51, 273
- Arnold JS, 1960, Quantitation of mineralization of bone as an orgen and tissue in osteoporosis, Clin Orthop, 17, 167
Cited by
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
“However, as has been reported previously (Ciarelli et al., 1991; Hvid et al., 1985; Keaveny, 1997), the limited density range exhibited by each site alone renders differences between predicted values from linear and power law models negligible.”
BackgroundResultQuantification of Bone Microarchitecture with the Structure Model Index
HILDEBRAND, T., & RÜEGSEGGER, P. (1997) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/01495739708936692 · Cited by 1,051
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.”
Fantner, G. E., Hassenkam, T., Kindt, J. H., Weaver, J. C., Birkedal, H., Pechenik, L., Cutroni, J. A., Cidade, G. A. G., Stucky, G. D., Morse, D. E., et al. (2005) · Nature Materials · doi:10.1038/nmat1428 · Cited by 933
Relations of mechanical properties to density and CT numbers in human bone
Rho, J. Y., Hobatho, M. C., & Ashman, R. B. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)97314-f · Cited by 822
Metadata
- Authors
- Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B.
- Affiliations
- University of Michigan (US)
- Henry Ford Health (US)
- Corresponding author
- Goldstein, S. A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1991-09
- Volume
- 9
- Issue
- 5
- Pages
- 674-682
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2048282929
- Cited by
- 401
- References
- 28
- Citations by year
- 2026: 10 · 2025: 6 · 2024: 16 · 2023: 21 · 2022: 7 · 2021: 12 · 2020: 13 · 2019: 9 · 2018: 12 · 2017: 8 · 2016: 8 · 2015: 7 · 2014: 17 · 2013: 14 · 2012: 11
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Orthopaedic Research® (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ar034399-12)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR34399)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, bone mineral density, elastic modulus, uniaxial compression, flexural failure, trabecular bone microarchitecture, cadaveric bone, tibia, femur, radius, humerus, bone strength
- MeSH terms
- Aged, Biomechanical Phenomena, Bone and Bones, Humans, Male, Middle Aged, Tomography, X-Ray Computed, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography. https://app.cochat.ai/papers/10.1002/jor.1100090507
- The paper
- Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991). Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100090507
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.