Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 177

The DOI matches its Crossref record.

On the influence of soft tissue coverage in the determination of bone kinematics using skin markers

Open access
Taylor, William R., Ehrig, Rainald M., Duda, Georg N., Schell, Hanna, Seebeck, Petra, Heller, Markus O. · 2005 · Journal of Orthopaedic Research

Abstract

Accurate measurement of underlying bone positions is important for the understanding of normal movement and function, as well as for addressing clinical musculoskeletal or post‐injury problems. Non‐invasive measurement techniques are limited by the analysis technique and movement of peripheral soft tissues that can introduce significant measurement errors in reproducing the kinematics of the underlying bones when using external skin markers. Reflective markers, skeletally mounted to the right hind limb of three Merino‐mix sheep were measured simultaneously with markers attached to the skin of each segment, during repetitions of gait trials. The movement of the skin markers relative to the underlying bone positions was then assessed using the Point Cluster Technique (PCT), raw averaging and the Optimal Common Shape Technique (OCST), a new approach presented in this manuscript. Errors in the position of the proximal joint centre, predicted from the corresponding skin markers, were shown to be phasic and strongly associated with the amount soft tissue coverage, averaging 8.5 mm for the femur, 2.8 for the tibia and 2.0 for the metatarsus. Although the results show a better prediction of bone kinematics associated with the Optimal Common Shape Technique, these errors were large for all three assessment techniques and much greater than the differences between the various techniques. Whilst individual markers moved up to 4 mm from the optimal marker set configuration, average peak errors of up to 16, 5 and 3 mm (hip, knee and tibio‐metatarsal joints respectively) were observed, suggesting that a large amount of kinematic noise is produced from the synchronous shifting of marker sets, potentially as a result of underlying muscle firing and the inertial effects of heel impact. Current techniques are therefore limited in their ability to determine the kinematics of underlying bones based on skin markers, particularly in segments with more pronounced soft tissue coverage. © 2005 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.orthres.2005.02.006

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 177

Metadata

Authors
Taylor, W. R., Ehrig, R. M., Duda, G. N., Schell, H., Seebeck, P., & Heller, M. O.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
2005-07
Volume
23
Issue
4
Pages
726-734
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W2148186001
Cited by
177
References
0
FWCI
4.10
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On the influence of soft tissue coverage in the determination of bone kinematics using skin markers. https://app.cochat.ai/papers/10.1016/j.orthres.2005.02.006
The paper
Taylor, W. R., Ehrig, R. M., Duda, G. N., Schell, H., Seebeck, P., & Heller, M. O. (2005). On the influence of soft tissue coverage in the determination of bone kinematics using skin markers. Journal of Orthopaedic Research. https://doi.org/10.1016/j.orthres.2005.02.006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.