A Comparison of Polysomnography and a Portable Home Sleep Study in the Diagnosis of Obstructive Sleep Apnea Syndrome
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To validate the role of a portable sleep monitor device (SNAP) in the diagnosis of obstructive sleep apnea syndrome (OSAS). Inter‐reader variability was also assessed for both PSG and SNAP. STUDY DESIGN AND SETTING: Sixty consecutive adults referred for PSG at The University of Chicago Sleep Disorder Clinic were prospectively enrolled. RESULTS: There was no significant difference between total number of apnea and hypopnea, respiratory disturbance index (RDI), and minimum oxygen obtained by PSG and SNAP, but there was a significant difference between sleep time and mean oxygen. Pearson's correlation coefficient for RDI ≥ 15 was 0.92. CONCLUSION: There was a significant correlation of RDIs between SNAP and PSG. SNAP has good sensitivity, specificity, positive and negative predictive values. Differences between SNAP and PSG could be attributed to inter‐reader variability and not necessarily due to technical limitations of SNAP. SNAP is an excellent tool for the diagnosis of OSAS in the laboratory setting. Future studies should be performed to evaluate SNAP's accuracy in the home setting in the diagnosis of OSAS. EBM rating: B‐2. (Otolaryngol Head Neck Surg 2004;131:844–50.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nieto, F. J. (2000) · JAMA · doi:10.1001/jama.283.14.1829 · Cited by 3,369
Young, T., Evans, L., Finn, L., & Palta, M. (1997) · Sleep · doi:10.1093/sleep/20.9.705 · Cited by 1,765
Strollo, P. J., & Rogers, R. M. (1996) · New England Journal of Medicine · doi:10.1056/nejm199601113340207 · Cited by 1,313
The Medical Cost of Undiagnosed Sleep Apnea
Kapur, V., Blough, D. K., Sandblom, R. E., Hert, R., de Maine, J. B., Sullivan, S. D., & Psaty, B. M. (1999) · Sleep · doi:10.1093/sleep/22.6.749 · Cited by 384
Cited by
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
El Shayeb, M., Topfer, L.-A., Stafinski, T., Pawluk, L., & Menon, D. (2014) · Canadian Medical Association Journal · doi:10.1503/cmaj.130952 · Cited by 237
A review of signals used in sleep analysis
Roebuck, A., Monasterio, V, Gederi, E., Osipov, M., Behar, J., Malhotra, A., Penzel, T., & Clifford, G. D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/1/r1 · Cited by 223
“…PSG. Liesching et al (2004) found that SNAP did not assess the severity of OSA correctly; Michaelson et al (2006) found that for an AHI 15 SNAP was 100% SN, 88.5% SP, 57% PPV and 100% NPV whereas Su et al (2004) found that 20% of patients were classified incorrectly using the SNAP system.”
MethodInfluentialMasa, J. F., Corral, J., Pereira, R., Duran-Cantolla, J., Cabello, M., Hernandez-Blasco, L., Monasterio, C., Alonso, A., Chiner, E., Rubio, M., et al. (2011) · Thorax · doi:10.1136/thx.2010.152272 · Cited by 161
An Economic Evaluation of Home Versus Laboratory-Based Diagnosis of Obstructive Sleep Apnea
Kim, R. D., Kapur, V. K., Redline-Bruch, J., Rueschman, M., Auckley, D. H., Benca, R. M., Foldvary-Schafer, N. R., Iber, C., Zee, P. C., Rosen, C. L., et al. (2015) · Sleep · doi:10.5665/sleep.4804 · Cited by 105
Respiratory Polygraphy With Actigraphy in the Diagnosis of Sleep Apnea-Hypopnea Syndrome
García-Díaz, E., Quintana-Gallego, E., Ruiz, A., Carmona-Bernal, C., Sánchez-Armengol, Á., Botebol-Benhamou, G., & Capote, F. (2007) · Chest · doi:10.1378/chest.06-1604 · Cited by 80
Metadata
- Authors
- Su, S., Baroody, F. M., Kohrman, M., & Suskind, D.
- Venue
- Otolaryngology–Head and Neck Surgery
- Publisher
- Wiley
- Published
- 2004-12
- Volume
- 131
- Issue
- 6
- Pages
- 844-850
- ISSN
- 0161-6439 (ISSN-L)
- 0194-5998
- 1097-6817
- OpenAlex
- W1977295966
- Cited by
- 78
- References
- 4
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.