Compound action potentials recorded in the human spinal cord during neurostimulation for pain relief
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Electrical stimulation of the spinal cord provides effective pain relief to hundreds of thousands of chronic neuropathic pain sufferers. The therapy involves implantation of an electrode array into the epidural space of the subject and then stimulation of the dorsal column with electrical pulses. The stimulation depolarises axons and generates propagating action potentials that interfere with the perception of pain. Despite the long-term clinical experience with spinal cord stimulation, the mechanism of action is not understood, and no direct evidence of the properties of neurons being stimulated has been presented. Here we report novel measurements of evoked compound action potentials from the spinal cords of patients undergoing stimulation for pain relief. The results reveal that Aβ sensory nerve fibres are recruited at therapeutic stimulation levels and the Aβ potential amplitude correlates with the degree of coverage of the painful area. Aβ-evoked responses are not measurable below a threshold stimulation level, and their amplitude increases with increasing stimulation current. At high currents, additional late responses are observed. Our results contribute towards efforts to define the mechanism of spinal cord stimulation. The minimally invasive recording technique we have developed provides data previously obtained only through microelectrode techniques in spinal cords of animals. Our observations also allow the development of systems that use neuronal recording in a feedback loop to control neurostimulation on a continuous basis and deliver more effective pain relief. This is one of numerous benefits that in vivo electrophysiological recording can bring to a broad range of neuromodulation therapies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Melzack, R., & Wall, P. D. (1965) · Science · doi:10.1126/science.150.3699.971 · Cited by 11,090 · cited 1×
“SCS was first attempted [23] in the 1960s after research into the gate control theory of pain, where it was observed that nonnoxious (eg, touch and vibration) activation of superficial fibres in the DC of the spinal cord inhibits pain transmission by a gate at the spinal segmental level [16].”
BackgroundMelzack, R., & Wall, P. D. (1996) · Pain Forum · doi:10.1016/s1082-3174(96)80062-6 · Cited by 2,784
Evidence for a central component of post-injury pain hypersensitivity
Woolf, C. J. (1983) · Nature · doi:10.1038/306686a0 · Cited by 2,157 · cited 1×
“This level of proximity and sensitivity in neuronal recording has not been presented previously with epidural electrodes but rather has necessitated microelectrode recording directly from the spinal cord [29].”
BackgroundElectrical inhibition of pain by stimulation of the dorsal columns: preliminary clinical report.
Shealy, C. N., Mortimer, J. T., & RESWICK, J. B. (1990) · PubMed · Cited by 1,237
Electrical Inhibition of Pain by Stimulation of the Dorsal Columns: Preliminary Clinical Report
SHEALY, C. N., MORTIMER, J. T., & RESWICK, J. B. (1967) · Anesthesia & Analgesia · doi:10.1213/00000539-196707000-00025 · Cited by 1,016 · cited 1×
“SCS was first attempted [23] in the 1960s after research into the gate control theory of pain, where it was observed that nonnoxious (eg, touch and vibration) activation of superficial fibres in the DC of the spinal cord inhibits pain transmission by a gate at the spinal segmental level [16].”
BackgroundDeterminants of conduction velocity in myelinated nerve fibers
Waxman, S. G. (1980) · Muscle & Nerve · doi:10.1002/mus.880030207 · Cited by 629 · cited 1×
“Nerve fibre conduction velocity is linearly related to the fibre diameter [28] (approximately 6 ms 1 per lm).”
BackgroundWhich Neuronal Elements are Activated Directly by Spinal Cord Stimulation
Holsheimer, J. (2002) · Neuromodulation: Technology at the Neural Interface · doi:10.1046/j.1525-1403.2002._2005.x · Cited by 247 · cited 5×
“Because the DC is innervated by 12 dermatomes at this level, Holsheimer concluded that there are only 4–5 fibres per dermatome recruited during SCS [8].”
BackgroundMethodInfluentialNew Trends in Neuromodulation for the Management of Neuropathic Pain
Aló, K. M., & Holsheimer, J. (2002) · Neurosurgery · doi:10.1097/00006123-200204000-00003 · Cited by 227 · cited 1×
“The goal of SCS is to completely cover—in a perceptual sense—the area of pain with paraesthesia because high levels of coverage are essential for effective pain relief [1].”
BackgroundMode of Action of Spinal Cord Stimulation in Neuropathic Pain
Meyerson, B. A., & Linderoth, B. (2006) · Journal of Pain and Symptom Management · doi:10.1016/j.jpainsymman.2005.12.009 · Cited by 158 · cited 2×
“and adenosine related inhibitory mechanisms [12,17].”
MethodFeirabend, H. K. P., Choufoer, H., Ploeger, S., Holsheimer, J., & van Gool, J. D. (2002) · Brain · doi:10.1093/brain/awf111 · Cited by 139 · cited 3×
“7 lm within 300 lm of the DC surface [5].”
BackgroundInfluential
Cited by
Kapural, L., Yu, C., Doust, M. W., Gliner, B. E., Vallejo, R., Sitzman, B. T., Amirdelfan, K., Morgan, D. M., Yearwood, T. L., Bundschu, R., et al. (2016) · Neurosurgery · doi:10.1227/neu.0000000000001418 · Cited by 470
Spinal Cord Stimulation: Clinical Efficacy and Potential Mechanisms
Sdrulla, A. D., Guan, Y., & Raja, S. N. (2018) · Pain Practice · doi:10.1111/papr.12692 · Cited by 375
Mekhail, N., Levy, R. M., Deer, T. R., Kapural, L., Li, S., Amirdelfan, K., Hunter, C. W., Rosen, S. M., Costandi, S. J., Falowski, S. M., et al. (2020) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30414-4 · Cited by 357
Self-citationClosed-loop Neurostimulation: The Clinical Experience
Sun, F. T., & Morrell, M. J. (2014) · Neurotherapeutics · doi:10.1007/s13311-014-0280-3 · Cited by 286
Russo, M., Brooker, C., Cousins, M. J., Taylor, N., Boesel, T., Sullivan, R., Holford, L., Hanson, E., Gmel, G. E., Shariati, N. H., et al. (2020) · Neurosurgery · doi:10.1093/neuros/nyaa003 · Cited by 95
Self-citation
Metadata
- Authors
- Parker, J. L., Karantonis, D. M., Single, P. S., Obradovic, M., & Cousins, M. J.
- Venue
- Pain
- Published
- 2012-03
- Volume
- 153
- Issue
- 3
- Pages
- 593-601
- ISSN
- 0304-3959 (ISSN-L)
- OpenAlex
- W1990309003
- Cited by
- 158
- References
- 22
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.