Essential tremor quantification during activities of daily living
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background Essential tremor (ET), characterized primarily by postural and kinetic tremor, is typically measured in the clinic with subjective tremor rating scales. These ratings are often used to adjust medications and assess efficacy in clinical trials. However, tremor ratings require the presence of a clinician and do not necessarily capture tremor fluctuations throughout the day during activities of daily living (ADL). Objective To evaluate the ability of motion sensors to discriminate tremor from voluntary posture and motion, classify tremor as postural or kinetic, and rate tremor severity during standardized tasks and non-standardized activities of daily living. Methods Ten subjects with ET wore motion sensors on the index finger and performed standardized motor tasks from the Washington Heights-Inwood Genetic Study of Essential Tremor (WHIGET) tremor rating scale (wTRS) and non-standardized ADL tasks. Four movement disorder specialists independently rated video segments of the standardized tasks but not the ADL tasks. Quantitative features were extracted from the motion sensors and used to develop mathematical models for predicting rating scores from kinematic data. Results The quantitative motion features were highly correlated with wTRS ratings for postural (r=0.90) and kinetic (r=0.80) tremors. Mathematical models produced tremor ratings that correlated strongly with clinician ratings of the wTRS tasks (mean r=0.80) and also produced ADL task ratings that correlated well with the most recent clinician wTRS ratings (mean r=0.72). Conclusions Recordings from motion sensors can be used to classify tremor as postural or kinetic and quantify tremor severity during both standardized and non-standardized activities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Salarian, A., Russmann, H., Wider, C., Burkhard, P. R., Vingerhoets, F. J. G., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886670 · Cited by 416 · cited 3×
“Due to previous difficulties in distinguishing voluntary motion from tremor, most attempts at continuous tremor recording have used motion sensors either to measure the duration of tremor occurrence or to quantify tremor amplitude in the absence of voluntary motion [17,18,21].”
BackgroundJankovic, J., Schwartz, K., Clemence, W., Aswad, A., & Mordaunt, J. (1996) · Movement Disorders · doi:10.1002/mds.870110306 · Cited by 235 · cited 1×
“Previously, accelerometers (actigraphy), gyroscopes, and electromyography (EMG) have been used extensively to obtain quantitative measurements of tremor in both Parkinson’s disease (PD) and ET [7,11–14].”
MethodSelf-citationEssential tremor frequency decreases with time
Elble, R. J. (2000) · Neurology · doi:10.1212/wnl.55.10.1547 · Cited by 166
Self-citationBrennan, K. C., Jurewicz, E. C., Ford, B., Pullman, S. L., & Louis, E. D. (2002) · Movement Disorders · doi:10.1002/mds.10003 · Cited by 121 · cited 1×
“The relative contribution of postural and kinetic tremor in ET can vary, though recent data suggest that kinetic tremor is more severe than postural tremor in ET [6], and the neural mechanisms that cause the two types of tremor in ET remain largely unknown [3].”
BackgroundEssential tremor—the most common movement disorder in older people
Thanvi, B., Lo, N., & Robinson, T. (2006) · Age and Ageing · doi:10.1093/ageing/afj072 · Cited by 102
Rapid tremor frequency assessment with the iPhone accelerometer
Joundi, R. A., Brittain, J.-S., Jenkinson, N., Green, A. L., & Aziz, T. (2011) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2011.01.001 · Cited by 69
Cited by
Clinician versus machine: Reliability and responsiveness of motor endpoints in Parkinson's disease
Heldman, D. A., Espay, A. J., LeWitt, P. A., & Giuffrida, J. P. (2014) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2014.02.022 · Cited by 156
“Advanced signal processing algorithms are able to discriminate tremor and dyskinesia from voluntary movements enacted during activities of daily living [3,18].”
BackgroundSelf-citationKim, H. B., Lee, W. W., Kim, A., Lee, H. J., Park, H. Y., Jeon, H. S., Kim, S. K., Jeon, B., & Park, K. S. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.02.007 · Cited by 124
Transducer‐based evaluation of tremor
Haubenberger, D., Abbruzzese, G., Bain, P. G., Bajaj, N., Benito‐León, J., Bhatia, K. P., Deuschl, G., Forjaz, M. J., Hallett, M., Louis, E. D., et al. (2016) · Movement Disorders · doi:10.1002/mds.26671 · Cited by 87
Self-citationProspective home-use study on non-invasive neuromodulation therapy for essential tremor
Isaacson, S. H., Peckham, E., Tse, W., Waln, O., Way, C., Petrossian, M. T., Dahodwala, N., Soileau, M. J., Lew, M., Dietiker, C., et al. (2020) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.59 · Cited by 79
Continuous in-home monitoring of essential tremor
Pulliam, C. L., Eichenseer, S. R., Goetz, C. G., Waln, O., Hunter, C. B., Jankovic, J., Vaillancourt, D. E., Giuffrida, J. P., & Heldman, D. A. (2014) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2013.09.009 · Cited by 74
Self-citation
Metadata
- Authors
- Heldman, D. A., Jankovic, J., Vaillancourt, D. E., Prodoehl, J., Elble, R. J., & Giuffrida, J. P.
- Venue
- Parkinsonism & Related Disorders
- Publisher
- Elsevier BV
- Published
- 2011-08
- Volume
- 17
- Issue
- 7
- Pages
- 537-542
- ISSN
- 1353-8020 (ISSN-L)
- OpenAlex
- W2092599090
- Cited by
- 110
- References
- 6
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Essential tremor quantification during activities of daily living. https://app.cochat.ai/papers/10.1016/j.parkreldis.2011.04.017
- The paper
- Heldman, D. A., Jankovic, J., Vaillancourt, D. E., Prodoehl, J., Elble, R. J., & Giuffrida, J. P. (2011). Essential tremor quantification during activities of daily living. Parkinsonism & Related Disorders. https://doi.org/10.1016/j.parkreldis.2011.04.017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.