Comparison of a commercial real-time PCR panel to routine laboratory methods for the diagnosis of meningitis-encephalitis

Chong, B.S.W., Kennedy, K.J.·2021·Pathology

Abstract

Meningitis-encephalitis can range from a mild, self limiting illness to a life threatening disease. Rapid microbial diagnosis allows for early targeted management. This study aimed to compare the BioFire FilmArray Meningitis/Encephalitis multiplex PCR panel (ME panel) to traditional testing algorithms for accuracy and turnaround time in the diagnosis of meningitis-encephalitis. From April to November 2018, cerebrospinal fluid (CSF) samples meeting existing laboratory testing criteria for suspected community acquired meningitis-encephalitis were tested on the ME panel and by routine laboratory methods. The methods were compared for accuracy of diagnosis and turnaround time. Where an organism was not identified, the study investigators came to a consensus on whether an infective aetiology was likely based on CSF parameters, clinical features, management and final discharge diagnosis. A total of 147 CSF samples met criteria for testing. Results were concordant in 143 (97%) of cases, including 27 samples where the same organism was identified by both methods. Of the four discordant samples, three organisms identified by the ME panel alone were considered clinically insignificant. One sample, which was culture and antigen positive for Cryptococcus neoformans, was not detected on the ME panel. The ME panel and routine methods identified an organism in 55% and 58% of clinically compatible cases of infection, respectively. The median turnaround time for the ME panel was 2.9 hours, compared to 21.1 hours for routine testing. The ME panel showed high concordance with traditional testing, simplified laboratory workflow, and significantly reduced turnaround time. The failure of the ME panel to detect Cryptococcus spp. is concerning. When cryptococcal meningitis is suspected, we would recommend using culture and cryptococcal antigen testing as the investigations of choice. Despite the availability of molecular assays targeting the common causes of CNS infection, the diagnostic yield remains suboptimal.

Integrity signals

Registry

Crossref · 10.1016/j.pathol.2020.09.029

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Chong, B. S. W., & Kennedy, K. J.
Affiliations
  • Canberra Hospital (AU)
  • Australian National University (AU)
Corresponding author
Chong, B.S.W.
Venue
Pathology
Publisher
Elsevier BV
Published
2021-08
Volume
53
Issue
5
Pages
635-638
ISSN
0031-3025 (ISSN-L)
OpenAlex
W3122805797
Cited by
17
References
8
Citations by year
2026: 4 · 2025: 4 · 2024: 2 · 2023: 2 · 2022: 5
FWCI
1.58
Type
journal article
Language
en
Open access
closed
Locations
  • Pathology (publishedVersion)
  • PubMed (publishedVersion)
  • ANU Open Research (Australian National University) (submittedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Bacterial Identification and Susceptibility Testing
  • Life Sciences › Immunology and Microbiology › Microbiology › Bacterial Infections and Vaccines
  • Health Sciences › Medicine › Infectious Diseases › Infectious Encephalopathies and Encephalitis
Keywords
BioFire FilmArray, multiplex PCR, cerebrospinal fluid, community-acquired meningitis, diagnostic accuracy, turnaround time, Cryptococcus neoformans, cryptococcal meningitis, molecular diagnosis
MeSH terms
Algorithms, Diagnostic Tests, Routine, Encephalitis, Female, Humans, Laboratories, Male, Meningitis, Sensitivity and Specificity, Multiplex Polymerase Chain Reaction, Real-Time Polymerase Chain Reaction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review