The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Comparative and stability study of glucose concentrations measured in both sodium fluoride and serum separator tubes
Published version of a preprint
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
Acidification of blood is superior to sodium fluoride alone as an inhibitor of glycolysis
Gambino, R., Piscitelli, J., Ackattupathil, T. A., Theriault, J. L., Andrin, R. D., Sanfilippo, M. L., & Etienne, M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.121707 · Cited by 160
Research works printed but not linked: 22
- Rolfe, 1992, Diabetes mellitus in the Gambia, west Africa, Diabet. Med.: A Journal British Diabetes Association, 9, 484, 10.1111/j.1464-5491.1992.tb01823.x · DOI
- Wild, 2004, Global prevalence of diabetes, Diabetes Care, 27, 1047, 10.2337/diacare.27.5.1047 · DOI · Paper page
- Gambino, 2007, Glucose: a simple molecule that is not simple to quantify, Clin. Chem., 53, 2040, 10.1373/clinchem.2007.094466 · DOI
- Chan, 1989, Effectiveness of sodium fluoride as a preservative of glucose in blood, Clin. Chem., 35, 315, 10.1093/clinchem/35.2.315 · DOI · Paper page
- Roux, 2004, A new antiglycolytic agent, Ann. Clin. Biochem., 41, 43, 10.1258/000456304322664681 · DOI
- Peake, 2013, It's time for a better blood collection tube to improve the reliability of glucose results, Diabetes Care, 36, 2, 10.2337/dc12-1312 · DOI
- Mikesh, 2008, Stabilization of glucose in blood specimens: mechanism of delay in fluoride inhibition of glycolysis, Clin. Chem., 54, 10.1373/clinchem.2007.102160 · DOI
- Waring, 2007, Glycolysis inhibitors negatively bias blood glucose measurements: potential impact on the reported prevalence of diabetes, J. Clin. Pathol., 60, 820, 10.1136/jcp.2006.039925 · DOI
- Fernandez, 2012, A comparison of glucose concentration in paired specimens collected in serum separator and fluoride/potassium oxalate blood collection tubes under survey ‘field’ conditions, Clin. Biochem., 46, 285
- Shi, 2009, Rapid blood separation is superior to fluoride for preventing in vitro reductions in measured blood glucose concentration, J. Clin. Pathol., 62, 752, 10.1136/jcp.2008.062547 · DOI
- Elleri, 2009, Effect of delay on measurement of blood glucose levels in young subjects with type 1 diabetes, Diabetes Res. Clin. Pract., 86, 31, 10.1016/j.diabres.2009.06.025 · DOI
- Turchiano, 2012, Impact of blood sample collection processing methods on glucose levels at community outreach studies, Journal of Environmental and Public Health, 2013, 1
- Frank, 2012, Blood glucose determination: plasma or serum, J. Clin. Lab. Anal., 26, 317, 10.1002/jcla.21524 · DOI
- Gambino, 2013, Sodium fluoride: an ineffective inhibitor of glycolysis, Ann. Clin. Biochem., 50, 3, 10.1258/acb.2012.012135 · DOI
- Bruns, 2013, Are fluoride-containing blood tubes still needed for glucose testing?, Clin. Biochem., 46, 289, 10.1016/j.clinbiochem.2013.01.009 · DOI
- Li, 2013, Comparison of glucose determinations on blood samples collected in three types of tubes, ACLS (Ann. Clin. Lab. Sci.), 43, 278
- Al-Kharusi, 2014, Are tubes containing sodium fluoride still needed for the measurement of blood glucose in hospital laboratory practice?, Oman Med. J., 29, 404, 10.5001/omj.2014.109 · DOI
- Bhargava, 2019, Should we still collect blood glucose sampling in fluoride tubes? An evidence-based study, Int. J. Diabetes Dev. Ctries., 39, 243, 10.1007/s13410-018-0688-0 · DOI
- Cuhadar, 2012, Stability studies of common biochemical analytes in serum separator tubes with or without gel barrier subjected to various storage conditions, The Journal of Croatian Society of Medical Biochemistry and Laboratory Medicine, 22, 202
- Spencer, 2011, Comparative stabilizing effects of some anticoagulants on fasting blood glucose of diabetics and non-diabetics, determined by spectrophotometry (glucose oxidase), Asian J. Med. Sci., 3, 234
- Ko, 2015, Comparison of red blood cell haemolysis plasma and serum separation tubes for outpatient specimens, Annals of Laboratory Medicine, 35, 194, 10.3343/alm.2015.35.2.194 · DOI
- Lippi, 2006, Influence of haemolysis on routine clinical chemistry testing, Clin. Chem. Lab. Med., 44, 311, 10.1515/CCLM.2006.054 · DOI · Paper page
Metadata
- Authors
- Dibbasey, M., Umukoro, S., & Bojang, A.
- Venue
- Practical Laboratory Medicine
- Publisher
- Elsevier BV
- Published
- 2024-03
- Volume
- 39
- Pages
- e00360
- ISSN
- 2352-5517
- Cited by
- 5
- References
- 2
- Language
- en
- Licence
- Funders
- Medical Research Council
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review