Accelerometer-based on-body sensor localization for health and medical monitoring applications
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this paper, we present a technique to recognize the position of sensors on the human body. Automatic on-body device localization ensures correctness and accuracy of measurements in health and medical monitoring systems. In addition, it provides opportunities to improve the performance and usability of ubiquitous devices. Our technique uses accelerometers to capture motion data to estimate the location of the device on the user’s body, using mixed supervised and unsupervised time series analysis methods. We have evaluated our technique with extensive experiments on 25 subjects. On average, our technique achieves 89% accuracy in estimating the location of devices on the body. In order to study the feasibility of classification of left limbs from right limbs (e.g., left arm vs. right arm), we performed analysis, based of which no meaningful classification was observed. Personalized ultraviolet monitoring and wireless transmission power control comprise two immediate applications of our on-body device localization approach. Such applications, along with their corresponding feasibility studies, are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
Research works printed but not linked: 37
- Bouten, 1997, Effects of placement and orientation of body-fixed accelerometers on the assessment of energy expenditure during walking, Medical and Biological Engineering and Computing, 35, 50, 10.1007/BF02510392 · DOI
- R.H. Barbieri, B.E Farella, B.A.L. Ricco, A low-power motion capture system with integrated accelerometers gesture recognition applications, in: International Symposium on VLSI Technology, Systems and Applications, 2004.
- L.J., 2009, Uwave: accelerometerbased personalized gesture recognition and its applications, IEEE International Conference on Pervasive Computing and Communications
- J. Mantyjarvi, J. Kela, P. Korpipaa, S. Kallin, Enabling fast and effortless customisation in accelerometer based gesture interaction, in: The 3rd international conference on Mobile and ubiquitous multimedia, 2004. · DOI
- L. Fu, I. Fellow, Gesture stroke recognition using computer vision and linear accelerometer, in: 8th IEEE International Conference on Automatic Face & Gesture Recognition, 2008.
- J.A.B. Link, G. Fabritius, M.H. Alizai, K. Wehrle, Burrowview: Seeing the world through the eyes of rats, in: The 2nd IEEE International Workshop on Information Quality and Quality of Service for Pervasive Computing, 2010.
- S.E.L.C, 2008, Identification of animal movement patterns using tri-axial accelerometry, Endangered Species Research, 6, 13C23
- Crawford, 2006, Which thermometer factors influencing best choice for intermittent clinical temperature assessment, Journal of Medical Engineering & Technology, 30, 199, 10.1080/03091900600711464 · DOI
- J. Lester, B. Hannaford, G. Borriello, using accelerometers to determine if two devices are carried by the same person, in: Proceedings of Second International Conference on Pervasive Computing (Pervasive 2004), 2004, pp. 33–50. · DOI · Paper page
- J. Lester, C. Hartung, L. Pina, R. Libby, G. Borriello, G. Duncan, Validated caloric expenditure estimation using a single body-worn sensor, in: UBICOMP ’09, 2009, pp. 225–234. · DOI
- Wegmueller, 2007, An attempt to model the human body as a communication channel, IEEE Transactions on Biomedical Engineering, 54, 1851, 10.1109/TBME.2007.893498 · DOI · Paper page
- Xu, 2011, Electric-field intrabody communication channel modeling with finite-element method, IEEE Transactions on Biomedical Engineering, 58, 705, 10.1109/TBME.2010.2093933 · DOI
- R.C. Shah, et al. On the performance of bluetooth and ieee 802.15.4 radios in a body area network, in: BODYNETS ’08, 2008, pp. 1–9. · doi:10.4108/icst.bodynets2008.2972
- E. Miluzzo, X. Zheng, K. Fodor, A.T. Campbell, Radio characterization of 802.15.4 and its impact on the design of mobile sensor networks, in: Proc. 5th European Conf. on Wireless Sensor Networks, EWSN 08, 2008, pp. 171–188. · doi:10.1007/978-3-540-77690-1_11
- A. Vahdatpour, N. Amini, M. Sarrafzadeh, On-body device localization for health and medical monitoring applications, in: PerCom ’11, 2011. · DOI
- Gellersen, 2002, Multi-sensor context-awareness in mobile devices and smart artifacts, Mobile Networks and Applications, 7, 341, 10.1023/A:1016587515822 · DOI · Paper page
- D. Minnen, et al. Improving activity discovery with automatic neighborhood estimation, in: IJCAI ’07, 2007, pp. 2814–2819.
- A. Vahdatpour, N. Amini, M. Sarrafzadeh, Toward unsupervised activity discovery using multi-dimensional motif detection in time series, in: IJCAI ’09, 2009, pp. 1261–1266.
- A. Vahdatpour, M. Sarrafzadeh, Unsupervised discovery of abnormal activity occurrences in multi-dimensional time series, with applications in wearable systems, in: SDM ’10: Siam Conference on Data Mining, 2010. · DOI
- Welk, 2000, The utility of the digi-walker step counter to assess daily physical activity patterns, Medicine and Science in Sports and Exercise, 32, S481, 10.1097/00005768-200009001-00007 · DOI · Paper page
- B. Chiu, E. Keogh, S. Lonardi, Probabilistic discovery of time series motifs, in: KDD ’03, 2003, pp. 493–498. · DOI · Paper page
- J. Aslam, K. Pelekhov, D. Rus, A practical clustering algorithm for static and dynamic information organization, in: SODA ’99: Proceedings of the Tenth Annual ACM-SIAM Symposium on Discrete Algorithms, Society for Industrial and Applied Mathematics. Philadelphia, PA, USA, 1999, pp. 51–60.
- N. Amini, J. Matthews, F. Dabiri, A. Vahdatpour, H. Noshadi, M. Sarrafzadeh, A wireless embedded device for personalized ultraviolet monitoring, in: BIODEVICES ’09, pp. 200–205, 2009. · doi:10.1117/12.828269
- Park, 1998, Topographic measurement of skin color by narrow-band reflectance spectrophotometer and minimal erythema dose in koreans, Skin Research and Technology, 4, 14, 10.1111/j.1600-0846.1998.tb00079.x · DOI
- K. Kleisouris, B. Firner, R. Howard, Y. Zhang, R.P. Martin, Detecting intra-room mobility with signal strength descriptors, in: MobiHoc ’10, 2010, pp. 71–80. · DOI
- Hackmann, 2008, Robust topology control for indoor wireless sensor networks, ACM Conference on Embedded Network Sensor Systems, 57, 10.1145/1460412.1460419 · doi:10.1145/1460412.1460419
- A. Kale, N. Cuntoor, V. Kruger, Gait-based recognition of humans using continuous hmms, in: Fifth IEEE International Conference on Automatic Face and Gesture Recognition, 2002.
- Gafurov, 2006, Biometric gait authentication using accelerometer sensor, Journal of Computers, 18, 51C
- K. Chang, J. Hightower, B. Kveton, Inferring identity using accelerometers in television remote controls, in: PerCom ’09, 2009. · DOI
- Barclay, 1978, Temporal and spatial factors in gait perception that influence gender recognition, Perception and Psychophysics, 23, 145C, 10.3758/BF03208295 · DOI · Paper page
- G.M. Weiss, J.W. Lockhart, Identifying user traits by mining smart phone accelerometer data, in: The Fifth International Workshop on Knowledge Discovery from Sensor Data (at KDD-11), 2011. · DOI
- Cho, 2004, Gender differences in three dimensional gait analysis data from 98 healthy korean adults, Clinical Biomechanics, 19, 145, 10.1016/j.clinbiomech.2003.10.003 · DOI · Paper page
- Mayagoitia, 2002, Standing balance evaluation using a triaxial accelerometer, Gait & Posture, 16, 55, 10.1016/S0966-6362(01)00199-0 · DOI · Paper page
- Lee, 2010, Symmetry in running gait using a single inertial sensor, Journal of Science and Medicine in Sport, 5, 559, 10.1016/j.jsams.2009.08.004 · DOI
- Arampatzis, 1999, The effect of speed on leg stiffness and joint kinetics in human running, Journal of Biomechanical, 12, 1349C, 10.1016/S0021-9290(99)00133-5 · DOI · Paper page
- Parijat, 2008, Effects of quadriceps fatigue on the biomechanics of gait and slip propensity, Gait Posture, 28, 568C, 10.1016/j.gaitpost.2008.04.001 · doi:10.1016/j.gaitpost.2008.04.001
- Dutto, 2002, Changes in spring-mass characteristics during treadmill running to exhaustion, Medical Science Sport Exercise, 34, 1324, 10.1097/00005768-200208000-00014 · DOI · Paper page
Cited by
Sensor Placement Variations in Wearable Activity Recognition
Kunze, K., & Lukowicz, P. (2014) · IEEE Pervasive Computing · doi:10.1109/mprv.2014.73 · Cited by 111
Gesture-Based Applications for Elderly People
Chen, W. (2013) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-39330-3_20 · Cited by 34
“Wii remote, [4, 5]) as well as face recognition and motion tracking with no sensors on the body or controller in the hands (e.”
BackgroundIntuitive Learnability of Touch Gestures for Technology-Naive Older Adults
Mihajlov, M., Law, E. L.-C., & Springett, M. (2015) · Interacting with Computers · doi:10.1093/iwc/iwu044 · Cited by 30
Metadata
- Authors
- Amini, N., Sarrafzadeh, M., Vahdatpour, A., & Xu, W.
- Venue
- Pervasive and Mobile Computing
- Publisher
- Elsevier BV
- Published
- 2011-12
- Volume
- 7
- Issue
- 6
- Pages
- 746-760
- ISSN
- 1574-1192 (ISSN-L)
- OpenAlex
- W2008753476
- Cited by
- 98
- References
- 1
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.