CoChat

Accuracy of angiogenic biomarkers at ⩽20weeks’ gestation in predicting the risk of pre-eclampsia: A WHO multicentre study

Open access
Widmer, Mariana, Cuesta, Cristina, Khan, Khalid S., Conde-Agudelo, Agustin, Carroli, Guillermo, Fusey, Shalini, Karumanchi, S. Ananth, Lapaire, Olav, Lumbiganon, Pisake, Sequeira, Evan, Zavaleta, Nelly, Frusca, Tiziana, Gülmezoglu, A. Metin, Lindheimer, Marshall D. · 2015 · Pregnancy Hypertension: An International Journal of Women's Cardiovascular Health
Cited by 75

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

OBJECTIVE To assess the accuracy of angiogenic biomarkers to predict pre-eclampsia. DESIGN Prospective multicentre study. From 2006 to 2009, 5121 pregnant women with risk factors for pre-eclampsia (nulliparity, diabetes, previous pre-eclampsia, chronic hypertension) from Argentina, Colombia, Peru, India, Italy, Kenya, Switzerland and Thailand had their serum tested for sFlt-1, PlGF and sEng levels and their urine for PlGF levels at ⩽20, 23-27 and 32-35weeks' gestation (index tests, results blinded from carers). Women were monitored for signs of pre-eclampsia, diagnosed by systolic blood pressure ⩾140mmHg and/or diastolic blood pressure ⩾90mmHg, and proteinuria (protein/creatinine ratio ⩾0.3, protein ⩾1g/l, or one dipstick measurement ⩾2+) appearing after 20weeks' gestation. Early pre-eclampsia was defined when these signs appeared ⩽34weeks' gestation. MAIN OUTCOME MEASURE Pre-eclampsia. RESULTS Pre-eclampsia was diagnosed in 198 of 5121 women tested (3.9%) of whom 47 (0.9%) developed it early. The median maternal serum concentrations of index tests were significantly altered in women who subsequently developed pre-eclampsia than in those who did not. However, the area under receiver operating characteristics curve at ⩽20weeks' gestation were closer to 0.5 than to 1.0 for all biomarkers both for predicting any pre-eclampsia or at ⩽34weeks' gestation. The corresponding sensitivity, specificity and likelihood ratios were poor. Multivariable models combining sEng with clinical features slightly improved the prediction capability. CONCLUSIONS Angiogenic biomarkers in first half of pregnancy do not perform well enough in predicting the later development of pre-eclampsia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.preghy.2015.09.004

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Widmer, M., Cuesta, C., Khan, K. S., Conde-Agudelo, A., Carroli, G., Fusey, S., Karumanchi, S. A., Lapaire, O., Lumbiganon, P., Sequeira, E., Zavaleta, N., Frusca, T., Gülmezoglu, A. M., & Lindheimer, M. D.
Venue
Pregnancy Hypertension: An International Journal of Women's Cardiovascular Health
Publisher
Elsevier BV
Published
2015-10
Volume
5
Issue
4
Pages
330-338
ISSN
2210-7789 (ISSN-L)
OpenAlex
W1600998794
Cited by
75
References
5
FWCI
7.46
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.