The DOI matches its Crossref record; 215 of the 215 references it cites were found in a registry or an index.
Optical coherence tomography angiography
Open accessAbstract
Optical coherence tomography (OCT) was one of the biggest advances in ophthalmic imaging. Building on that platform, OCT angiography (OCTA) provides depth resolved images of blood flow in the retina and choroid with levels of detail far exceeding that obtained with older forms of imaging. This new modality is challenging because of the need for new equipment and processing techniques, current limitations of imaging capability, and rapid advancements in both imaging and in our understanding of the imaging and applicable pathophysiology of the retina and choroid. These factors lead to a steep learning curve, even for those with a working understanding dye-based ocular angiography. All for a method of imaging that is a little more than 10 years old. This review begins with a historical account of the development of OCTA, and the methods used in OCTA, including signal processing, image generation, and display techniques. This forms the basis to understand what OCTA images show as well as how image artifacts arise. The anatomy and imaging of specific vascular layers of the eye are reviewed. The integration of OCTA in multimodal imaging in the evaluation of retinal vascular occlusive diseases, diabetic retinopathy, uveitis, inherited diseases, age-related macular degeneration, and disorders of the optic nerve is presented. OCTA is an exciting, disruptive technology. Its use is rapidly expanding in clinical practice as well as for research into the pathophysiology of diseases of the posterior pole.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–215 of 215
Pepple, K. L., & Mruthyunjaya, P. (2011) · Seminars in Ophthalmology · doi:10.3109/08820538.2011.570850 · Cited by 42
Lumbroso, B. D., Rispoli, M., Savastano, M. C., Jia, Y., Tan, O., & Huang, D. (2016) · Developments in ophthalmology · doi:10.1159/000442782 · Cited by 42
A mechanistic link between renal ischemia and fibrosis
Tanaka, T. (2016) · Medical Molecular Morphology · doi:10.1007/s00795-016-0146-3 · Cited by 42
Mitochondrial dysfunction in optic neuropathies: animal models and therapeutic options
Carelli, V., Morgia, C. L., & Sadun, A. A. (2013) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32835c5f0b · Cited by 41
Best's vitelliform macular dystrophy.
Godel, V., CHAINE, G., Regenbogen, L. S., et al. (1986) · PubMed · Cited by 41
Campbell, M., Humphries, M. M., Kennan, A., Kenna, P. F., Humphries, P., & Brankin, B. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2006.01.032 · Cited by 39
Strauss, R. W., Muñoz, B. E., Jha, A., Ho, A., Cideciyan, A. V., Kasilian, M. L., Wolfson, Y., Sadda, S. R., West, S. K., Scholl, H. P. N., et al. (2016) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2016.06.003 · Cited by 31
Self-citationFundus Autofluorescence Imaging in Age-Related Macular Degeneration and Geographic Atrophy
Bearelly, S., & Cousins, S. W. (2009) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-1399-9_45 · Cited by 28
Spaide, R. F. (2017) · Retina · doi:10.1097/iae.0000000000001575 · Cited by 28
Self-citationMarques, J. P., Costa, J. F., Marques, M. F., Cachulo, M. L., Figueira, J., & da Silva, R. M. (2016) · Ophthalmic Research · doi:10.1159/000442671 · Cited by 27
Treatments for macular oedema following central retinal vein occlusion: systematic review
Ford, J. A., Clar, C., Lois, N., Barton, S., Thomas, S., Court, R. A., Shyangdan, D., & Waugh, N. R. (2014) · BMJ Open · doi:10.1136/bmjopen-2013-004120 · Cited by 25
MICROVASCULAR FLOW ABNORMALITIES ASSOCIATED WITH RETINAL VASCULITIS
Spaide, R. F. (2016) · Retina · doi:10.1097/iae.0000000000001359 · Cited by 23
Self-citationLeukocyte plugging and cortical capillary flow after subarachnoid hemorrhage
Ishikawa, M., Kajimura, M., Morikawa, T., Tsukada, K., Tsuji, T., Kusaka, G., Tanaka, Y., & Suematsu, M. (2016) · Acta Neurochirurgica · doi:10.1007/s00701-016-2792-6 · Cited by 22
Indocyanine Green Angiography in Fundus flavimaculatus
Schwoerer, J., Secrétan, M., Zografos, L., & Piguet, B. (2000) · Ophthalmologica · doi:10.1159/000027498 · Cited by 20
CORRELATION BETWEEN MICROANEURYSMS AND RETINAL THICKNESS IN DIABETIC MACULAR EDEMA
Blair, N. P., Shahidi, M., Lai, W. W., et al. (2008) · Retina · doi:10.1097/iae.0b013e318177f8ec · Cited by 18
Cited by
Artificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779
Current understanding of the molecular and cellular pathology of diabetic retinopathy
Antonetti, D. A., Silva, P. S., & Stitt, A. W. (2021) · Nature Reviews Endocrinology · doi:10.1038/s41574-020-00451-4 · Cited by 645
Neurodegeneration in diabetic retinopathy: does it really matter?
Simó, R., Stitt, A. W., & Gardner, T. W. (2018) · Diabetologia · doi:10.1007/s00125-018-4692-1 · Cited by 591
Mettu, P. S., Allingham, M. J., & Cousins, S. W. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100906 · Cited by 370
Laíns, I., Wang, J. C., Cui, Y., Katz, R., Vingopoulos, F., Staurenghi, G., Vavvas, D. G., Miller, J. W., & Miller, J. B. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2021.100951 · Cited by 324
Self-citation
Metadata
- Authors
- Spaide, R. F., Fujimoto, J. G., Waheed, N. K., Sadda, S. R., & Staurenghi, G.
- Venue
- Progress in Retinal and Eye Research
- Publisher
- Elsevier BV
- Published
- 2018-05
- Volume
- 64
- Pages
- 1-55
- ISSN
- 1350-9462 (ISSN-L)
- OpenAlex
- W2775636951
- Cited by
- 1,779
- References
- 215
- FWCI
- 44.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.