Presbyopia: Effectiveness of correction strategies
Open accessAbstract
ABSTRACT Presbyopia is a global problem affecting over a billion people worldwide. The prevalence of unmanaged presbyopia is as high as 50% of those over 50 years of age in developing world populations, due to a lack of awareness and accessibility to affordable treatment, and is even as high as 34% in developed countries. Definitions of presbyopia are inconsistent and varied, so we propose a redefinition that states “presbyopia occurs when the physiologically normal age‐related reduction in the eye's focusing range reaches a point, when optimally corrected for distance vision, that the clarity of vision at near is insufficient to satisfy an individual's requirements”. Strategies for correcting presbyopia include separate optical devices located in front of the visual system (reading glasses) or a change in the direction of gaze to view through optical zones of different optical powers (bifocal, trifocal or progressive addition spectacle lenses), monovision (with contact lenses, intraocular lenses, laser refractive surgery and corneal collagen shrinkage), simultaneous images (with contact lenses, intraocular lenses and corneal inlays), pinhole depth of focus expansion (with intraocular lenses, corneal inlays and pharmaceuticals), crystalline lens softening (with lasers or pharmaceuticals) or restored dynamics (with ‘accommodating’ intraocular lenses, scleral expansion techniques and ciliary muscle electrostimulation); these strategies may be applied differently to the two eyes to optimise the range of clear focus for an individual's task requirements and minimise adverse visual effects. However, none fully overcome presbyopia in all patients. While the restoration of natural accommodation or an equivalent remains elusive, guidance is given on presbyopic correction evaluation techniques. HighlightsPresbyopia is a global problem affecting over a billion people worldwide.Prevalence of unmanaged presbyopia is high even in developed countries.New definition proposed to overcome lack of current consistency.Reasonable evidence for effectiveness of many refractive and surgical managements.Ideal correction not yet achieve, but pharmaceutical & intraocular lens contenders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nickla, D. L., & Wallman, J. (2010) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2009.12.002 · Cited by 1,945
Helmholtz's treatise on physiological optics
(1924) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(24)90484-4 · Cited by 696
Presbyopia and the optical changes in the human crystalline lens with age
Glasser, A., & Campbell, M. C. W. (1998) · Vision Research · doi:10.1016/s0042-6989(97)00102-8 · Cited by 601
Global Vision Impairment Due to Uncorrected Presbyopia
Holden, B. A. (2008) · Archives of Ophthalmology · doi:10.1001/archopht.126.12.1731 · Cited by 436
Bayesian adaptive estimation of the contrast sensitivity function: The quick CSF method
Lesmes, L. A. (2010) · Journal of Vision · doi:10.1167/10.3.17 · Cited by 333
Multifocal versus monofocal intraocular lenses in cataract surgery
Leyland, M., & Zinicola, E. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00722-x · Cited by 285
Age-related changes in optical and biometric characteristics of emmetropic eyes
Atchison, D. A., Markwell, E. L., Kasthurirangan, S., Pope, J. M., Smith, G., & Swann, P. G. (2008) · Journal of Vision · doi:10.1167/8.4.29 · Cited by 270
THE DESIGN AND USE OF A NEW NEAR-VISION CHART
Bailey, I. L., & Lovie, J. E. (1980) · American journal of optometry and physiological optic · doi:10.1002/j.2330-9512.1980.tb02805.x · Cited by 265
The development and maintenance of emmetropia
Brown, N. P., Koretz, J. F., & Bron, A. J. (1999) · Eye · doi:10.1038/eye.1999.16 · Cited by 237
The Global Burden of Potential Productivity Loss from Uncorrected Presbyopia
Frick, K. D., Joy, S. M., Wilson, D. A., Naidoo, K. S., & Holden, B. A. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.04.014 · Cited by 226
Cited by
Correction of presbyopia: old problems with old (and new) solutions
Kollbaum, P. S., & Bradley, A. (2020) · Clinical and Experimental Optometry · doi:10.1111/cxo.12987 · Cited by 45
Assessment of visual quality improvement as a result of spectacle personalization
Benyó, F., István, L., Kiss, H., Gyenes, A., Erdei, G., Juhász, É., Vlasak, N., Unger, C., Andorfi, T., Réz, K., et al. (2023) · Life · doi:10.3390/life13081707 · Cited by 6
Oscar, G.-E., Irene, S., & Raul, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-38446-6 · Cited by 2
Metadata
- Authors
- Wolffsohn, J. S., & Davies, L. N.
- Venue
- Progress in Retinal and Eye Research
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 68
- Pages
- 124-143
- ISSN
- 1350-9462 (ISSN-L)
- OpenAlex
- W2890293715
- Cited by
- 324
- References
- 129
- FWCI
- 16.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Presbyopia: Effectiveness of correction strategies. https://app.cochat.ai/papers/10.1016/j.preteyeres.2018.09.004
- The paper
- Wolffsohn, J. S., & Davies, L. N. (2019). Presbyopia: Effectiveness of correction strategies. Progress in Retinal and Eye Research. https://doi.org/10.1016/j.preteyeres.2018.09.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.