Visual satisfaction with progressive addition lenses prescribed with novel foveal fixation axis measurements
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Progressive addition lens (PAL) prescription is usually conducted using the pupillary centre as a reference, which in general does not coincide with the visual axis (kappa distance), and this difference could induce undesired prismatic effects in far and near vision distances and adaptation problems. This study aimed to assess the impact on subjects’ visual satisfaction with PALs prescribed based on foveal fixation axis (FFA) measurements. Two different PALs (LifeStyle 3i, Hoya Lens Iberia) were randomly prescribed [one with a customized inset (the difference between the FFA measurements (Ergofocus®, Lentitech, Spain) at far and near distances and the second with a standard inset (2.5 mm)] to be used by 71 healthy presbyopic volunteers in a prospective double-masked crossover clinical study involving one month of use of each PAL. Patients were self-classified into four groups according to their previous experience with PALs: neophyte, PAL users, PAL drop-out, and uncomfortable PAL users. Visual function and overall satisfaction with each PAL were collected and compared. Ninety-seven percent (95% CI 93–100%) of participants successfully adapted to PALs prescribed with FFA without significant differences (P = 0.26) among the study groups (100% neophyte and uncomfortable PAL users (95% CI 100% in both groups), 89% (95% CI 67–100%) PAL users and 94% (95% CI 82–100%) PAL drop-out group). There were no statistically significant differences in visual function (P > 0.05) between customized and standard inset PALs. Customized and standard inset lenses showed similar satisfaction (P > 0.42) that increased significantly (P < 0.01 without any carry-over effect) after 30 days of wear. PALs prescribed with FFA measurements showed high visual satisfaction, suggesting that these measurements are suitable for prescribing PAL adaptation processes. Additional research is necessary to assess differences in PAL users’ performance with different prescription methods and lens designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Adaptation appears faster, and patient satisfaction is higher with FFLs”
From Freeform vs. Aspheric Spectacle Lenses: A Comprehensive Review of Optical Performance, Clinical Outcomes, and Patient Considerations (2026) · cites this paper as [55]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Voutilainen, A., Pitkäaho, T., Kvist, T., & Vehviläinen‐Julkunen, K. (2016) · Journal of Advanced Nursing · doi:10.1111/jan.12875 · Cited by 382
Presbyopia: Effectiveness of correction strategies
Wolffsohn, J. S., & Davies, L. N. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.09.004 · Cited by 324
(2019) · doi:10.18356/9df3caed-en · Cited by 299
Chang, D. H., & Waring, G. O. (2014) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2014.06.028 · Cited by 162
Optical Zone Centration in Keratorefractive Surgery
Pande, M., & Hillman, J. S. (1993) · Ophthalmology · doi:10.1016/s0161-6420(93)31500-9 · Cited by 157
Measurement of Angle Kappa With Synoptophore and Orbscan II in a Normal Population
Başmak, H., Şahin, A., Yıldırım, N., Papakostas, T. D., & Kanellopoulos, A. J. (2007) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20070501-06 · Cited by 153
Pande, M., & Hillman, J. S. (1993) · PubMed · Cited by 146
Meister, D. J., & Fisher, S. W. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2007.00245.x · Cited by 114
Design, Analysis, and Reporting of Crossover Trials for Inclusion in a Meta-Analysis
Li, T., Yu, T., Hawkins, B. S., & Dickersin, K. (2015) · PLOS ONE · doi:10.1371/journal.pone.0133023 · Cited by 107
Progressive Powered Lenses: the Minkwitz Theorem
Sheedy, J. E., Campbell, C. E., King-Smith, E., & Hayes, J. R. (2005) · Optometry and Vision Science · doi:10.1097/01.opx.0000181266.60785.c9 · Cited by 98
Research works printed but not linked: 2
- Chamorro, E., Cleva, J. M., Concepción, P., Subero, M. & Alonso, J. Lens design techniques to improve satisfaction in free-form progressive addition lens users. JOJ Ophtalmol. 6, 555688 (2018).
- Rabbetts, R. Bennet & Rabbetts’ Clinical Visual Optics (Butterworth-Heinemann-Elsevier, 2007).
Cited by
Presbyopia: Current Perspectives and Prospects for Patients
Davies, L. N. (2026) · Ophthalmic and Physiological Optics · doi:10.1007/s44402-026-00083-7 · Cited by 3
Ladopoulos, K., Pateras, E., & Ninos, G. (2026) · Cureus · doi:10.7759/cureus.104008
Metadata
- Authors
- Oscar, G.-E., Irene, S., & Raul, M.
- Affiliations
- Universidad de Valladolid (ES)
- Corresponding author
- Irene, Sanchez
- Venue
- Scientific Reports
- Published
- 2023-07-12
- Volume
- 13
- Issue
- 1
- Pages
- 11262-11262
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC10338446
- OpenAlex
- W4384069059
- Cited by
- 2
- References
- 37
- Citations by year
- 2026: 2
- FWCI
- 0.40
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Hispana (publishedVersion, cc-by)
- UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
- Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Keywords
- progressive addition lenses, lens prescription, visual satisfaction, presbyopia, prismatic effect, lens adaptation, visual axis, residual effects
- MeSH terms
- Acclimatization, Humans, Lenses, Personal Satisfaction, Prospective Studies, Apocynaceae
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Visual satisfaction with progressive addition lenses prescribed with novel foveal fixation axis measurements. https://app.cochat.ai/papers/10.1038/s41598-023-38446-6
- The paper
- Oscar, G.-E., Irene, S., & Raul, M. (2023). Visual satisfaction with progressive addition lenses prescribed with novel foveal fixation axis measurements. Scientific Reports. https://doi.org/10.1038/s41598-023-38446-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.