Marginal and internal fit of CAD-CAM inlay/onlay restorations: A systematic review of in vitro studies
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
STATEMENT OF PROBLEM: Different parameters can influence the adaptation of computer-assisted design and computer-assisted manufacturing (CAD-CAM) inlay/onlay restorations. However, systematic reviews to identify and discuss these parameters are lacking. PURPOSE: The purpose of this systematic review was to summarize the scientific literature investigating all parameters that can influence both the marginal and internal adaptation of CAD-CAM inlay/onlay restorations. MATERIAL AND METHODS: An electronic search was conducted by 2 independent reviewers for studies published in English between January 1, 2007 and September 20, 2017 on the PubMed/MEDLINE, Scopus, and Web of Science databases and in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Factors investigated in the selected articles included the type of CAD-CAM system, virtual space parameters, version of the software, type of block, luting procedure, type of restoration, sample size and aging procedure, evaluation method, and number of measurement points per specimen. RESULTS: A total of 162 articles were identified, of which 23 articles met the inclusion criteria. Nine studies investigated adaptation with different restorative materials, 2 evaluated adaptation according to the type of preparation design, 9 compared adaptation before/after thermomechanical loading, and 2 before/after cementation, 1 study investigated marginal adaptation based on whether the optical scan was made intraorally or extraorally, 1 compared adaptation with 5 and 3 axis CAM systems, and 1 assessed adaptation with 4 different intraoral scanners. The risk of bias was high for 7, medium for 15, and low for 1 of the studies reviewed. The high level of heterogeneity across the studies excluded meta-analysis. CONCLUSIONS: Most of the studies reported clinically acceptable values for marginal adaptation. The performance of a CAD-CAM system is influenced by the type of restorative material. A nonretentive cavity preparation exhibited better adaptation than a retentive preparation. Most studies showed that thermomechanical loading affected the quality of marginal adaptation. Cementation increased marginal discrepancies. No statistically significant difference was found for marginal fit of onlays between intraoral and extraoral optical scans using a stone die. The number of milling axes, the type of digital camera, and the region measured were statistically significant in relation to marginal/internal adaptation. Values of adaptation recorded failed to reproduce the preestablished spacer parameters in the software. Clarification is needed concerning adaptation according to the type of preparation design, the type of material, the choice of intrinsic parameters for the CAD process, the type and shape of milling instruments, and the behavior of the material during milling. Adaptation of CAD-CAM inlay/onlays should be evaluated under clinical conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PRISMA-P Group, Moher, D., Shamseer, L., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., & Stewart, L. A. (2015) · Systematic Reviews · doi:10.1186/2046-4053-4-1 · Cited by 26,223 · cited 1×
“This systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement.(29) An electronic search was performed, using 3 electronic databases (PubMed/MEDLINE, Scopus, and Web of Science) for studies published between January 1, 2007 and September 20,…”
MethodThe future of dental devices is digital
van Noort, R. (2012) · Dental Materials · doi:10.1016/j.dental.2011.10.014 · Cited by 1,408
The estimation of cement film thickness by an in vivo technique
McLean, J. W., & von, F. (1971) · British Dental Journal · doi:10.1038/sj.bdj.4802708 · Cited by 1,383
Five-year clinical results of zirconia frameworks for posterior fixed partial dentures.
Sailer, I., Fehér, A., Filser, F., Gauckler, L. J., Lüthy, H., & Hämmerle, C. H. F. (2007) · PubMed · Cited by 807
Considerations in measurement of marginal fit
Holmes, J. R., Bayne, S. C., Holland, G. A., & Sulik, W. D. (1989) · The Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(89)90170-4 · Cited by 769
Advancements in CAD/CAM technology: Options for practical implementation
Alghazzawi, T. F. (2016) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2016.01.003 · Cited by 637 · cited 2×
“The rotary instrument size and shape of the milling unit can influence the adaptation of a restoration.(2,4,25,61,67,70,77) Overmilling of any surface details less than the diameter of the milling rotary instrument will result in a less accurate restoration,(2,70) especially at the line angles of the preparation.”
BackgroundBond strength of universal adhesives: A systematic review and meta-analysis
Rosa, W. L. D. O. D., Piva, E., & Silva, A. F. D. (2015) · Journal of Dentistry · doi:10.1016/j.jdent.2015.04.003 · Cited by 584 · cited 1×
“) independently evaluated the risk of bias of each included study using an adaptation of the methods applied in 2 previous systematic reviews of in vitro studies.(30,31) Descriptions of the following parameters were used to assess each article’s risk of bias (Supplemental Table 1, available online): randomization of t…”
MethodMechanical properties of resin-ceramic CAD/CAM restorative materials
Awada, A., & Nathanson, D. (2015) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.04.016 · Cited by 581
Emerging Ceramic-based Materials for Dentistry
Denry, I., & Kelly, J. R. (2014) · Journal of Dental Research · doi:10.1177/0022034514553627 · Cited by 464
Wear, strength, modulus and hardness of CAD/CAM restorative materials
Lawson, N. C., Bansal, R., & Burgess, J. O. (2016) · Dental Materials · doi:10.1016/j.dental.2016.08.222 · Cited by 364
Metadata
- Authors
- Goujat, A., Abouelleil, H., Colon, P., Jeannin, C., Pradelle, N., Seux, D., & Grosgogeat, B.
- Venue
- The Journal of Prosthetic Dentistry
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 121
- Issue
- 4
- Pages
- 590-597.e3
- ISSN
- 0022-3913 (ISSN-L)
- OpenAlex
- W2902350504
- Cited by
- 208
- References
- 43
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Marginal and internal fit of CAD-CAM inlay/onlay restorations: A systematic review of in vitro studies. https://app.cochat.ai/papers/10.1016/j.prosdent.2018.06.006
- The paper
- Goujat, A., Abouelleil, H., Colon, P., Jeannin, C., Pradelle, N., Seux, D., & Grosgogeat, B. (2019). Marginal and internal fit of CAD-CAM inlay/onlay restorations: A systematic review of in vitro studies. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2018.06.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.