Cited by 96Advanced Fiber Optic SensorsStructural Health Monitoring TechniquesSmart Materials for Construction

Fibre optic sensors for the structural health monitoring of building structures

Open access
Bremer, K., Wollweber, M., Weigand, F., Rahlves, M., Kuhne, M., Helbig, R., Roth, B.·2016·Procedia Technology

Abstract

In this work different fibre optic sensors for the structural health monitoring of civil engineering structures are reported. A fibre optic crack sensor and two different fibre optic moisture sensors have been designed to detect the moisture ingress in concrete based building structures. Moreover, the degeneration of the mechanical properties of optical glass fibre sensors and hence their long-term stability and reliability due to the mechanical and chemical impact of the concrete environment is discussed as well as the advantage of applying a fibre optic sensor system for the structural health monitoring of sewerage tunnels is demonstrated.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.protcy.2016.08.065

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Moisture absorption can alter material properties, potentially leading to false damage features and incorrect damage identifications.

    “Due to the absorption of moisture, material properties can be altered, potentially leading to false damage features and incorrect damage identifications [125].”

    From Effects of Environmental and Operational Conditions on Structural Health Monitoring and Non-Destructive Testing: A Systematic Review (2023) · cites this paper as [125]

    Sections 2.1 and 2.2 describe sensor materials swelling when exposed to water and the resulting changes in optical readings. They do not say that moisture alters the structural material’s properties or produces false damage features or incorrect damage identifications. No page numbers are available in our copy. (LLM, conf=0.76)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Thevenaz L, Facchini M, Fellay A, Robert Ph, Inaudi D, Dardel B. Monitoring of large structures using distributed Brillouin fiber sensing. SPIE Proc. 1999; 3746; pp. 345-348

Cited by

Sorted by citations

Authors
Bremer, K., Wollweber, M., Weigand, F., Rahlves, M., Kuhne, M., Helbig, R., & Roth, B.
Affiliations
  • Leibniz University Hannover (DE)
  • Sächsisches Textilforschungsinstitut (DE)
  • Materialfoschngs- und -prüfanstalt Weimar (DE)
Corresponding author
Bremer, K.
Venue
Procedia Technology
Publisher
Elsevier BV
Published
2016
Volume
26
Pages
524-529
ISSN
2212-0173 (ISSN-L)
OpenAlex
W2526076785
Cited by
96
References
3
Citations by year
2026: 8 · 2025: 20 · 2024: 13 · 2023: 11 · 2022: 9 · 2021: 12 · 2020: 8 · 2019: 6 · 2018: 7 · 2017: 2
FWCI
2.31
Type
journal article
Language
en
Open access
Locations
  • Procedia Technology (publishedVersion, cc-by-nc-nd)
  • Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by-nc-nd)
  • Publication Server of Weimar Bauhaus-University (Weimar Bauhaus-University) (submittedVersion, cc-by-nc-nd)
  • Common Library Network (Der Gemeinsame Bibliotheksverbund) (submittedVersion, cc-by-nc-nd)
  • Leibniz Universität Hannover (cc-by-nc-nd)
Funders
  • Bundesministerium für Bildung und Forschung (03ZZ0345)
  • Bundesministerium für Wirtschaft und Energie
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
  • Physical Sciences › Engineering › Civil and Structural Engineering › Structural Health Monitoring Techniques
  • Physical Sciences › Environmental Science › Pollution › Smart Materials for Construction
Keywords
fiber optic sensors, structural health monitoring, building structures, concrete, moisture ingress, crack detection, long-term sensor stability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review